ML20046C408
| ML20046C408 | |
| Person / Time | |
|---|---|
| Site: | Big Rock Point File:Consumers Energy icon.png |
| Issue date: | 07/31/1993 |
| From: | Donnelly P, Jeanne Johnston CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.) |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| NUDOCS 9308110001 | |
| Download: ML20046C408 (6) | |
Text
_
.m.
I,
,[
f
.a:
l I
Consumers POWar Patrick M Donnelly Plant Manager POWERING MKNSGAN5 PROGRESS Big Rock Point Nuclear Plant,10269 UE.31 North, Charlevoix, M149720 F
August 2, 1993 j
1 i
i Nuclear Regulatory Commission Document Control Desk Washington, DC 20555
Dear Sir:
Enclosed please find the statistical data for the Big Rock Point Nuclear Plant covering the period of July 1,1993 through July 31, 1993.
j u
Sinc ely, 6'
-l
. A P M Donnelly i
1
. Plant Manager Enclosures 1
cc: Administrator Region III, Nuclear Regulatory Commission l
DRHahn, Department of Public Heath JRPadgett, Michigan Public Service Commission
- i RAben, Michigan Department of Labor MPCass, American Nuclear Insurers FYost, Research Services Utility Data Institute INPO Records Center NRC Resident Inapector i
Document Control, Big Rock Point, 740/22*35*10 l
DPilotfman, P24-117A GCWithrow, Big Rock Point File i
4 l
/
9308110001 930731 -
[b
[
'PDR ADOCK 05000155
-R:
PDR..jSi.
- A CMSENE7?GYCOMPANY
@ Commmers Power NUCLEAR OPERATIONS DEPARTMENT company Unit Shutdowns and Power Reductions Report Month Docket Numter Unit Date Completed by Telephone July 1993 55-150 Big Rock Nint Plant August 2, 1993 JE JORX510M (6261 547-8223 Method of Shutting Duration Down Ucensee Event System Component l
4 Number Date Type (Hours)
Rearon Reactor Report Number Code Code 6 Cause end Corrective Action To Prevent Recurrence on 06/26/93 at 03:27; started Refueling Outage C3-03 06/26/93 5
744.0 Brs C
2 thru for 1993.
(Total hrs = 860.$)
07/31/93 I
2 3
4 F = Forced Reason:
Method:
Exhibit G = Instructions for S = Scheduled A = Equipment Failure (Explain) 1 = Manual Preparation of Data Entry Sheets B = Maintenance of Test 2 = Manual Scram for Licensee Event Report (LER)
C = Refueling 3 = Automatic Scram File (NUREG-0161)
D = Regulatory Restriction 4 = Other (Explain)
E = Operator Training and License Examination 5Exhibit i = Same Source F = Administrative
'3 = Operational Error (Explain)
H = Other (Explain)
Form 3156 1-82
GREYBOOK OFEtoTTNO DnT4 F:EFenT LM E T NO. t 0-155 S 05 E /
3 p g m y;g OrEPuTING STATUS PHONE:
616-E17-6537 TEXT 223 g,
- 1. UNIT HnME:
BIG ROCK POINT NUClit.eR PL4NT NOTES
- _ **FO*TYrS-PPRIOD
- 7 73 32 LIGNTED THERMOL POtER (MWTi.
290 4.
N #EPL41E F4 TING (GPO55 MWE):
7E
.J. ET.Sif*ttECYMTCMffiG. ;,E T' ; ; C i.
71
- 6. MAXIt#)M DEFEND (.0LE CAPACITY-(GROSS MWE):
71.0
- 7. MaMIMUM DEFEMDcBLE CAPACITY tNET MWE):
67.0
,,-trYNME?-M?t-Tii CiaCTTY-PftTIMe?tTTE F 3 TP*tr-TMTME nfe?-*r*MTv-ere-*PM---
- i. a e
8
' to
- 9. POWER LEVEL TO WHICH RESTRICTED,IF ntW (NCT t1WE D :
.-ttri'ffr*mS-70P ME?TM T7Tet!St----i-i +TJ g
o e
3
- ,,[
THIS NONTH YEAR-TO I E COMUL4TIVE cr
- 11. HD' 'R5 IN FEPOPTING FERIOD 744.0 F09 7. 9 2654'Pe ()
- 12. NUMEER OF H9UD5 RE4CTOR WM GITICuL O.C 411; 1W
- h., 't (19r-MEuCTCWREttfWE liwYCOteft-hot.G
,.O e.m
- v s e-- -- - --- -- --- - -- -
i't a HOURS GENER4 TOR ON-LINE 0.0 4104.9 190:50.6
- 15. UNIT RESERVE SHQTDOWN HOUR 5 0.0 0.0 0.0
,.y M-P*9?? TH** P'f t~ **+E*SY-Of'P'EPeTmMt*M P-'--
U-3 t *^ 2+ --
3+?e'**P _e-
- 17. GROSS ELECTRICol ENERGY GENEPATED (MWH)
'). 6 157'rio.
11 D t24.n
',-t?NI T MERYIG-FisOff a
- 19. NZT ELECTP.Ict4L ENERGY GENERATED mWH I 0.0 24 W4 2. '
10705 S:9 J.G.
J 0 r?%
~'? i Cr% ~ - - - -
- 20. UNIT AVAIL 40ILITY FACTOR 0.0%
90.7%
71.2%
' g
- 21. UNIT CAPACITY F(v TOR (USING MOC NET) 0.0%
71.5%
50.9%
,, W r t*tTT en1*rC I TY-PtY"TCMt+S T+S-O'*~ NET t M4
+$.".--
-F7.M
- 23. UNIT FORCED OUTAGE PATE 3.0%
0,0%
11.5%
n
.mm
.-a
.-.--.4,
-,, +
4.+
m-._
N-f 5.
ir 9 T 0024 OT END OF REPORT PERIOfir ESTIMnTED OniE or SToRTUP nUuU~T 1E 19'_
~
O
~. -. _ _ _ -. _ - _., -. - - - -
un b
r m
F*k 9'
C
~ _ _ _ _.
C r
_ AVEiiAGE DAILY POWER (MWT)
(MWEN) 8 7/?3)
CYCLE 26
. DA'd
-p(
1 0.00 0.00 2
0.00 0,00 v.vv v.vu 4
0.00 0.00.
- s 5
0.00 0.00
-8 v.vu v.vu a
7 0.00 0.00 l
8 0.00 0.00 v.VV 7
V.vV y
10:
0.00 0.00-N 9'.k9 '
9'99 f
te v vv v vv 13 0.00 0.00 14 0.00 0.00
't
- 'VV V'VV o
16 0.00 O.00 17-0.00 0.00 v.VV v.VV AG 19 0.00 0.00 l
- s,,
20 0.00 0.00 se v.vv ta v.vv 22 O.00 0.00 23 0.00 0.00 l
v.vu v.vu av 25 0.00 0.00 26 0.00 0.00 v.vv v.vu
- 26 0.00 0.00 29 0.00 0.00 v.vu v.vv av 31 0.00 0.00 a
3' l
I
, 32 m
?
i l
a m
S'
)*
i i
=
a j et
<t 43 da 1
[
d5 N
]
Ei i
=
]
e
)
l' a
. c
~
- he :
w*p e
1 O.
i
- 1.
- Refueling _IRf2rmation Reauest 1.
Facility Name:
Big Rock Point plant l
2.
Scheduled date for next refueling shutdown: June, 1993 l
3.
Scheduled date for restart following shutdown: August, 1993
'{
4.
Will refueling or resumption of operation thereaf ter require a technical specification change or other license amendment? No If yes, explain:
If no, has the reload fuel design and core configuration been reviewed by -
[
Plant Safety Review Committee to determine whether any unreviewed safety t
questions as associated with the core reload (Reference 10 CFR, Section 50.59)? Yes If no review has taken place, when is it scheduled?
I 5.
Scheduled date(s) for submittal of proposed licensing action and supporting i
information:
6.
Important licensing considerations associated with refueling, eg. new or different fuel design or supplier, unreviewed design or performance analysis methods, significant changes in fuel design new operating procedures:
i 4
7.
Number of fuel assemblies in: core 0 ; spent fuel pool storage 378; new i
fuel storage 22.
l 8.
Present licensed spent fuel pool storage capacity: 441 Size of any increase in licensed storage capacity that has been requested or planned (in number of fuel assemblies): 0 9.
Projected date of last refueling that can be discharged to spent fuel pool assuming the present license capacity: Last total core off load 1996; Last j
refueling 1999.
RE WELINC.146
-August 2, 1993
)
i
FORM 16.3.H Operating Status Report - Nuclear Regulatory Commission 7!2
//IS Prepared by:
AfM/BU/
[#
. _)
Date:
Reviewed by:
70 Date:
.3 n
(Reactor Engineer or Alternate)
Copy to be sent to the following by the seventh day of each month:
Nuclear Regulatory Commission Fred Yost Document' Control' Desk" Director, Research Services Washington, DC 20555 Utility Data Institute 1700 K Street, N.W.
Administrator Suite 400 Region III - USNRC Washington, DC 20006 799 Roosevelt Road Glen Ellyn, IL 60137 DR Hahn, NFEM Division of Radiological Health Department of Public Health 3500 North Logan Lansing, MI 48906 JR Padgett Michigan Public Service Commission PO Box 30221 Lansing, MI 48909 Institute of Nuclear Power Operations Plant Analysis Department 700 Galleria Parkway Atlanta, GA 30339-5957 e
Robert Aben, Assistant Chief Bureau of Construction Codes Michigan Department of Labor i
7150 Harris Drive, Box 30015 Lansing, MI 48909 American Nuclear Insurers Att: MP Cass Town Center, Suite 300S 29 South Main Street West Hartford, CT 06107-2445 Routing Copy:
'DP Iloffman, P26-117A SM McIntyre, P13-121 JL Lampman, Big Rock Point Plant RC Joba, Big Rock Point Plant i
NRC Resident Inspector, Big Rock Point Plant Document Control Center, Big Rock Point Plant DCC 740*22*35*10 i
(740822*10*04) Cross Reference covensarrr. col August 2, 1993 16.3.3 - 17