Forwards Requalification Program Evaluation Rept 50-336/93-12OL-RQ on 930601-03.Overall Rating Satisfactory
ML20045G665
Person / Time
Site: Millstone Dominion icon.png
Issue date: 07/06/1993
From: Bettenhausen L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Opeka J
NORTHEAST NUCLEAR ENERGY CO.
Shared Package
ML20045G666 List:
References
NUDOCS 9307150024
Download: ML20045G665 (3)


See also: IR 05000336/1993012

Text

i

b

$

JUL

G 1993

Docket No. 50-336

Mr. John F. Opeka

Executive Vice President - Nuclear

Northeast Nuclear Energy Company

P. O. Box 270

Hartford, Connecticut 06141-0270

Dear Mr. Opeka:

SUBJECT: REQUALIFICATION PROGRAM EVALUATION REPORT NO.

50-336/93-12 (OL-RQ)

From June 1 - 3, 1993, the NRC administered requalification examinations to thirteen

employees of your company who operate the Millstone Unit 2 Plant. Twelve of the thirteen

operators passed the written, walkthrough, and simulator portions of the examination. One

operator failed the written portion of the examination, and seven additional operators passed

the simulator portion. As a result of these evaluations, your requalification program has

been assigned an overall program rating of satisfactory in accordance with the criteria of

NUREG-1021, ES-601.

This evaluation addressed areas important to public health and safety ed was conducted in

accordance with Revision 7 to NUREG-1021, " Operator Licensing Examiner Standards," ES-

601, " Administration of NRC Requalification Program Evaluations." The evaluation had two

purposes, evaluating the effectiveness of the licensed operator requalification training

program at maintaining the competency oflicensed operators, and examining the individual

operators to determine if they would satisfy the regulatory rcquirement of passing an NRC-

administered examination prior to license renewal. At the conclusion of the examination, the

l

results of the examination were discussed with Mr. Ruth, Mr. Becker, and other members of

l

l

your staff.

In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of this letter and

the enclosure will be placed in the NRC Public Document Room.

i

OFFICIAL RECORD COPY

G:MS9312.RER

i

l

D

DO K O 00

.

,

l

,

-~

.

. _ _ .

'JUL

61993

,

Mr. John F. Opeka

2

Should you have any questions regarding this examination and inspection, please contact me

at 215-337-5291.

Sincerely,

f

/'

Lee H. Bettenhausen, Chief

Operations Branch

Division of Reactor Safety

Enclosure: Requalification Program Evaluation Report No.

50-336/93-12 (OL-RQ) w/ Attachments 1 and 2

Attachments:

1. Northeast Utilities Letter MP-93-514 from S. E. Scace

to Dr. L. Bettenhausen, dated June 28,1993

2. Simulator Facility Report

,

cc w/ encl; w/o Attachments 1 and 2:

W. D. Romberg, Vice President, Nuclear Operations

J. S. Keenan, Nuclear Unit Director

,

'

R. M. Kacich, Director, Nuclear Licensing

D. O. Nordquist, Director of Quality Services

M. Wilson, Nuclear Licensing

i

Gerald Garfield, Esquire

Nicholas Reynolds, Esquire

NRC Resident Inspector

State of Connecticut, SLO

cc w/enci and Attachments 1 and 2:

S. E. Scace, Vice President, Millstone Station

'

R. Spurr, Acting Supervisor, Training Department

.

F

Public Document Room (PDR)

Local Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

-

1

OFFICIAL RECORD COPY

G:MS9312.RER

. - - .

__

.

- -_

,

.

..

JUL

61993-

.

Mr. John F. Opeka

-3

bec w/ encl; w/o Attachments 1 and 2:

K. Ihnen, Chief Examiner, DRS

Mark Jones, NRC Consultant (EG&G)

Frank Jaggar, NRC Consultant (EG&G)

OL Facility File

bec w/ concurrences and w/ encl; w/o Attachments 1 and 2:

k

Region I Doc. et Room

bec w/ encl and Attachments 1 and 2:

Master Exam File

-l

.

bec w/ encl; w/o Attachments 1 and - (VIA E-MAIL):

2

V. McCree, OEDO

G. Vissing, PM, NRR

R. Gallo, Chief, OLB, NRR

NOTIFY VIA E-MAIL AND NO ATTACIIED FILE

W. Lanning, DRP

L. Bettenhausen, DRS

R. Blough, DRP

J. Durr, DRS

R. Conte, DRS

G. Meyer, DRS

L. Doerflein, DRP

K. Ihnen, DRS

P. Swetland, SRI

RI:DRS

RI:DRS

RI:DRS

Be

ausen

1hrien/dmg

Meyer

07M/93

07/01/93

07/(/93

OFFICIAL RECORD COPY

G:MS9312.RER

-.

.

_

_

_ . - . _ .

.

.

.