Up 3

I' VIHOINIA EL1:crurc AND POWlut COMI%NY R ICH M ON D, Valt OINIA 20261 July 8, 1993 U.S. Nuclear Regulatory Commission Serial No.93-303 Attention: Document Control Desk NES/ISI/PJN/EJW Washington, D.C. 20555 Docket No.

50-338 License No.

NPF-4 1

Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNIT 1 1993 REFUELING OUTAGE INSERVICE INSPECTION

SUMMARY

REPORT Pursuar;t to the provisions of ASME Section XI, Virginia Electric and Power Company hereby submits the enclosed Inservice inspection Report for the North Anna Power Station Unit 1 1993 Refueling outage. This report is a summary of examinations performed during the outage for the second period of the North Anna Unit 1 second ten-year inservice inspection interval. The report consists of three attachments.

The first attachment, Form NIS-1, Owner's Report for Inservice Inspections, and the second attachment, Form NIS-2, Owner's Report of Repair and Replacement and the associated summaries, are provided pursuant to IWA-6220 of the 1983 Edition of ASME Section XI, Summer 1983 Addenda.

The third attachment provides the Evaluation Analysis of Examination Results pursuant to IWB-3125(b) of the 1983 Edition of ASME Section XI, Summer 1983 Addenda.

If you have any further questions, please contact us.

Very truly yours, h

i W. L. Stewart I

Senior Vice President - Nuclear Attachment 1

130029

/

1 9307130333 930708 t

PDR ADOCK 05000338 h!

3 G

PDR

&l

. e e

t cc:

U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, N.W.

Suite 2900 Atlanta, Georgia 30323 NRC Senior Resident inspector North Anna Power Station