ML20045D717

From kanterella
Jump to navigation Jump to search
Application for Amends to Licenses DPR-77 & DPR-79, Consisting of TS Change 93-07,allowing Relaxation of Eol Mtc Limit in Clor.Westinghouse Nonproprietary & Proporietary Repts on Subj Encl.Proprietary Rept Withheld
ML20045D717
Person / Time
Site: Sequoyah  
Issue date: 06/21/1993
From: Fenech R
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML19303F658 List:
References
NUDOCS 9306290345
Download: ML20045D717 (3)


Text

i 5

A

_ _ _ _.. _ ~

. _ -.. ~..... _ _

Termst se Vaney Authonty, Post Ofhee Box 2000 Saddy-Daisy, Tennessee 37379 2000 l

Robert A. Fenech Vce President, Sequoyah Nuclear Plant June 21, 1993 TVA-SQN-TS-93-07 10 CFR 50.90 U.S. Nuclear Pegulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Gentlemen:

In the Matter of

)

Docket Nos. 50-327 Tennessee Valley Authority

)

50-328 SEQUOYAH NUCLEAR PLANT (SQN) - TECHNICAL SPECIFICATION (TS) CHANGE 93-07, END OF LIFE (EOL) MODERATOR TEMPERATURE COEFFICIENT (MTC) RELAXATION in accordance with 10 CFR 50.90, we are enclosing a requested amendment to Licenses DPR-77 and DPR-79 to change the TSs of SQN Units 1 and 2.

'Ihe proposed change includes an analysis supporting a more negative E0L MTC.

The changes tr. allow relaxation of the EOL MTC limit in the Core Operating Limits Report are based on Westinghouse Electric Corporation methodology in Westinghouse Commercial Atomic Power (WCAP) No. 13631.

The analysis is SQN specific, but is similar to that approved for use at other nuclear power plants. The WCAP is being submitted as Enclosure 5 to this requested TS change.

The proposed TS change is identified in Enclosure 1.

.The justification for the i>roposed TS change is provided in Enclosure 2.

A proposed-determ.m. tion of no significant hazards consideration performed pursuant to 10 CFR 50.92 is provided in Enclosure 3. contains +he application for withholding WCAP-13631 from public disclosure. contains WCAP-13631, which is the proprietary version and contains specific numeric values to support this submittal.

provides the nonproprietary version labeled WCAP-13650.

Since WCAP-13631 contains information proprietary to Westinghouse, contains the application for withholding and affidavit (CAW-93-435) signed by Westinghouse, the owner of the information T e&l i50017 p

g 9306290345'930621 O

PDR ADDCK 05000327 3 3l P

PDR w

i l

U.S. Nuclear Regulatory Commission l

Page 2 June 21, 1993 l

l as well as the proprietary information notice and copyright notice. The npplication for withholding and the affidavit set forth the basis on which the information may be withheld from public disclosure by NRC and address with specificity the considerations listed in paragraph (b)(4) of Section 2.790 of NRC regulations.

Accordingly, it is respectively requested that the information that is proprietary to Westinghouse be withheld from public disclosure in accordance with 10 CFR, Section 2.790, of NRC regulations.

l l

Correspondence, with respect to the copyright or proprietary aspects of the items listed above or the supporting Westinghouse affidavit, should reference CAW-93-435 and should be addressed to N. J. Liparulo, Manager of Nuclear Safety and Regulatory Activities, Westinghouse Electric Corporation, P.O. Box 355, Pittsburgh, Pennsylvania 15230-0355.

1 TVA requests a 45-day implementation period for this TS change following l

issuance. Additionally, TVA requests this change be approved by l

October 1, 1993. This date is based upon an anticipated need for this TS change 100 days after restart of Unit 2.

Please direct questions concerning this issue to W. C. Ludwig at (615) 843-7460.

Sincerely, Mk Robert A. Fenech l

Sworn to and subscr ed before me this 2/Ed da of 1993 n ( O. O Notary Pub 1'ic 1/

My Commission Expires /

77 Enclosures cc:

See page 3 l

l l

I I

l U.S. Nuclear Regulatory Commission Page 3 June 21, 1993 1

Enclosures cc (Enclosures):

Mr. D. E. LaBarge, Project Manager U.S. Nuclear Regulatory Commiasion One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852-2739 Mr. Michael H. Mobley, Director (w/o Enclosures)

Division of Radiological Health 3rd Floor L & C Annex 401 Church Street Nashville, Tennessee 37243-1532 NRC Resident Inspector Sequoyah Nuclear Plant j

2600 Igou Ferry Road Soddy-Daisy, Tennessee 37379-3624 l

\\

Regional Administrator U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323-2711 l-

.