Text

.

FROLRKORD GH

SAFEGUARDSa WORMAT,0N

~

-

N l1 d

Docket Nos. 50-259, 50-260, 50-296

License Nos. DPR-33, DPR-52, DPR-68

Tennessee Valley Authority

ATTN: Dr. Mark 0. Medford

Vice President, Technical

Support

3B Lookout P1 ace

SARGLIARDS INFORMATION REMOVED

1101 Market Street

Chattanooga, TN 37402-2801

Gentlemen:

.

SUBJECT:

NOTICE OF VIOLATION

(NRC INSPECTION REPORT NOS. 50-259/93-22,50-260/93-22,AND

50-296/93-22)

This refers to the inspection conducted by A. Tillman of this office on

May 24-29, 1993.

The inspection included a review of activities. authorized

for your Browns Ferry Nuclear Plant facility. At'the conclusion of the

inspection, the findings were discussed with those members of your staff

identified in the enclosed report.

Areas examir.ed during the inspection are identified in the report.

Within

these areas, the inspection consisted of selective examinations of procedures

and representative records, interviews with personnel, and observation of

activities in progress.

Based on the results of this inspection, certain of your activities appeared

to be in violation of NRC requirements, as specified in the enclosed Notice of

Violation (Notice).

The violation is of concern because the multiple examples

demonstrated a failure to adhere to established procedural requirements and

the inadequacy of initial corrective action.

You are required to respond to this letter and should follow the instructions

specified in the enclosed Notice when preparing your response.

In your-

response, you should document the specific actions taken and any additional

actions you plan to prevent recurrence. After reviewing your response to this

Notice, including your proposed corrective actions and the results of future

inspections, the NRC will determine whether.further NRC enforcement action is

necessary to ensure compliance with NRC regulatory requirements.

The material enclosed herewith contains Safeguards Ir.formstion as defined by

'

10 CFR Part 73.21 and its disclosure to unauthorized individuals is prohibited

by Section 147 of the Atomic Energy Act of 1954, as amended.

Therefore, the

,

material will not be placed in the Public Document Room.

3

9306250050 930618

%,nNsrYa

I

"""wt00A RDS NF0HATIO F'~""$,

PDR

ADOCK 05000259

inomvam W * 5**"

s

p

--

SAFEGilARDS INFORMATiON

'

-

M, / j Jg

Tennessee Valley Authority

2

The responses directed by this letter and the enclosed Notice are not subject

to the clearance procedures of the Office of Management and Budget as required

by the Paperwork Reduction Act of 1980, Pub. L. No.96-511.

Should you have any questions concerning this letter, please contact us.

Sincerely,

h

dl}Ol'4 f S49 al-

Old

Man

[1 ouglas M. Collins, Chief

Nuclear Materials Safety and

Safeguards Branch

Division of Radiation Safety

and Safeguards

Enclosures:

1.

Notice of Violation

(Safeguards Information)

2.

NRC Inspection Report

-

(Safeguards Information)

cc w/ encl:

R. M. Eytchison, Vice President

Nuclear Operations

Tennessee Valley Authority

3B Lookout Place

1101 Market Street

Chattanooga, TN 37402-2801

0. J. Zeringue, Vice President

Browns Ferry Operations

Tennessee Valley Authority

P. O. Box 2000

Decatur, AL 35602

Mark J. Burzynski, Manager

Nuclear Licensing and

Regulatory Affairs

Tennessee Valley. Authority

5B Lookout Place

1101 Market Street

Chattanooga, TN 37402-2801

cc w/ Inspection Summary:

W. H. Kennoy, Director

Tennessee Valley Authoritv

ET 12A

400 West Summit Hill Drive

Knoxville, TN 37902

.

[h)C&Jrrm?rft trarnrFHtted herewitPS

(cc w/ Inspection Summary cont'd - See page 3)

gpg",$"g','gd, , ,

8ARGl AOS 50RMATl01

~~'-'~~

-- --- --

.

u

SAFEGUARDS 1FORMATl0K

-

.

Tennessee Valley Authority-

3-

)

(cc w/ Inspection Summary cont'd)

i

Site Licensing Manager

Browns Ferry Nuclear Plant

Tennessee Valley Authority

'

P. O. Box 2000

Decatur, AL 35602

TVA Representative

Tennessee Valley Authority

Rockville Office

11921 Rockville Pike

Suite 402

Rockville, MD 20852

General Counsel

Tennessee Valley Authority

ET 11H

400 West Summit Hill Drive

Knoxville, TN 37902

Chairman, Limestone County

.

Commission

P. O. Box 188

Athens, AL 35611

State Health Officer

Alabama Department of Public Health

434 Monroe Street

Montgomery, AL' 36130-1701

Manager, Nuclear Assurance

and Licensing

Browns Ferry Nuclear Plant -

Tennessee Valley Authority

P. O. Box 2000

Decatur, AL 35602

bec w/1nspection Summary:

E. W. Merschoff, RII

J. R. Johnson, RII

P. J. Kellogg, RII

B. M. Bordenick, 0GC

M. S. Callahan, GPA/CA

T. M. Ross, NRR

G. Lainas, NRR

F. Hebdon, NRR

(bec w/ Inspection Summary cont'd - See page 4)

US75.TY

SMEGOARDS INFORMAT!0M

====--

,

.

.

SAM 10ARDS li4FORMATl01

~

'

-

dh1 1,d g

Tennessee Valley- Authority

4

(bec w/ Inspection Summary cont'd)

HRC Resident Inspector

U.S.~ Nuclear Regulatory Comm.

Route 12,-Box 637

-

Athens, AL 35611

'

bec w/encls:

NRR/DRIS/SB

,

'i

RII:DRS

RII:DRSS

RII

P

NM

/> T.lleo

-

'

MCGUIRE C

TILLMAN

KEL QGG

06/fT/93

06/j]/93

06/[993

.

8AFEGUARDS 31F0WAT101

'

===r:

'" A* % 2 e % a

.

.