Rev 0 to Operating Procedure TVA-EOP-6, Insp of Intermediate Deck Doors
ML20045C790
Person / Time
Site: Sequoyah  
Issue date: 02/28/1976
From: George J, Howell R, Sutherland J
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
Shared Package
ML20045C607 List:
References
TVA-EOP-6, NUDOCS 9306240374
Download: ML20045C790 (4)


Text

y ', *F '* GPERATING FROCEDURE 9

I WESTINGMOUSE ELECTRIC CORPORATION Nucita* Ervsrgy Sysums P.O. Son 335 i,

Eit tsuurgn. Pe nnsylvania 1$2*,Q.

-(

ae visio~ so o4reo oaic matissue zu,caseces TVA-EOP-6

[eb1eoruary 1976 0

[X]

m vious AcvisioNs 1

TENNESSEE VALLEY AUTHORITY

^rl ACHMENTS

]

ra atCT:

SEQUOYAH NUCLEAR PLANT UNIT N05. 1 AND 2 l

INSPECTION OF INTERMEDIATE DECK 000R 'I

sce OncEa: 902 i

$YSTEM:

ICE CONDENSER

/

Fon SUPPLIE A's CONVENtENCE All' underlined portions of this procedure

"'oi

"'"',5'." $,"7,' " '

are mandatory and certified for construction. ;

I I

I e

l i

l This Document Contains Proprietary information of Westinghouse Electric Corporation (PWR Systems Division) and is to be returned upon request. Its contents may not be dis-

-j i

closed to others or used for other than the expressed purpose for which loaned without the l

written consent of Westinghouse.

/kjC APPROV A LS onicaualissvc n e v.

a r v. :

a e v. s n e v. 4 J. D. Sutherland JD.6 AUTHOR shop onoEH HOLDER R. L. Howell l ' /hWI

  1. 75 k

. uxurow. Ice Condenser Ecuip J. A. George, _,:;f&, gry k

Cognizant Engr

-h l/ d r

iw

~'

9306240374 730217 3'

e, PDR ADOCK 0S000327 U PDR f

y e

- = =.

........ n...

.c.

TVA-E0P-6 f

3 Revisicn Revisions Revised By 0

Original Issue w -

e e

d mule 6

as Iw-em 4

i e

x t

\\

m

~

i

. ' f., ',

TVA-EOP-6 Page a.

[

PREFACE The intermediate deck doors provide a barrier between the ice bed and the upper ice condenser plenum.

Vents are provided in the deck for pressure equalization.

The technical specification recuires that each intermediate deck door be inscected at least once per tnree months to verify it is closed.

Eacn door snall be aemonstrated to be operable at leas t once per three months during the first year and once per 18 months thereafter by:

1.

Visually verifying there is no frost accumulation or structural deterioration.

2.

Verifying free movement of the vent assemblies.

3.

Ascertaining free movement of the doors when lifted with the applicable force listed belew:

Door Lifting Force Adjacent to crane wall

< 37.4 lbs Paired with door adjacent 7 33.8 lbs to crane wall Adjacent to containment wall

< 31.8 lbs Paired with door adjacent to 7 31.0 lbs containment wall me 9

t 4

L

TVA-EOP-6 INSPECTION OF INTERkEDI ATE DECK DOORS

~~

I

(

l.0 DRAWING LIST None.

2.0 INSPECTION PROCEDURE Note: The intermediate deck doors should not be opened until the " initial opening" force is measured.

2.1 Measure the " initial opening" force.

2.1.1 Measure the force required to open the door with a spring scale attached to the outer edge.

The force should be applied slowly.

Record the measured force.

If the maximum allowable force listed in the Preface is exceeded, the door should be cleaned of any frost accumula tion.

2.1.2 Repeat the measurement by closing the door and re-opening it.

Record the measured force.

2.1.3 Repeat the measurer 5ents for all doors to be inspected.

N 2.2 Visual inspection of door condition.

g 2.2.1 Visually inspect the top surface of all intermediate deck doors for abnormal ice formation.

2.2.2 Visually inspect the deck frame / wall panel seal strips for opening or looseness of the caulking.

If defective, replace the strips or recaulk

~

the joints.

~

2.2.3 Visually inspect the door seals after the opening forca measurements have been completed.

2.2.4 Inspect the flaps of the deck vents for free and unobstructed motion in both directions.

2.3 Special Equipment 2.3.1 Chatillon spring scale (model DPPH-50). Range of 0 to 50 pounds with 0.S pound increments.

i 2.4 Documentation s

[

2.4.1 Record any anomaly observed during the visual inspection of the doors and door frame-wall panel seal strips.

2.4.2 Record the condition of the door seal strip.

(~

2.4.3 Record the conditions of the intermediate deck vents.

2.4.4 Record the opening force measurements.