, _ _ _ _ _ _ . - _ - - - _ _ _ _ _ _

.t

UNITED ST ATES .

f O.

a "c(k

.

NUCLEAR REGULATORY COMMISSION

-t

_p

[;, h ' 8

611 RY AN PLAZA DRIVE, SUITE 400

j

REGION IV

o

-

AR LINGT ON, T E X AS 76011 -8064

.

g

  • ....

M

9%

'

Docket:

50-298

License: DPR-46

-

Nebraska Public Power District

ATTN: Guy R. Horn, Nuclear Power

Group Manager

P.O. Box 499

Columbus, Nebraska 68602-0499

SUBJECT:

NRC INSPECTION REPORT 50-298/93-18 (NOTICE OF VIOLATION)

This refers to the inspection conducted by Mr. C. E. Johnson of this office on

April 26-30 and May 10-14, 1993. The inspection included a review of

activities authorized for your Cooper Nuclear Station facility. At the

conclusion of the inspection, the findings were discussed with those members

of your staff identified in the enclosed report.

Areas examined during the inspection are identified in the' report. Within

these areas, the inspection consisted of selective examinations of procedures

and representative records, interviews with personnel, and observation of

-l

activities in progress.

l

,

Based on the results of this inspection, certain licensed activities appeared

to be in violation of NRC requirements, as specified in the enclosed Notice of

Violation (Notice).

The Notice contains two violations that pertain to your

handling of radiation monitors.

The first violation concerns inadequate corrective actions to properly

maintain a safety-related control room ventilation ra<liation monitor. This

violation is of concern because it indicates the failure to resolve a long-

standing weakness in the establishment of adequate corrective' actions and root

causes of inoperability.

The second violation concerns an inadequate safety evaluation review of a

design change modification to a drywell ventilation radiation monitor. This

proposed change, which had been partially completed at the time of the

inspection, involved the replacement of a radiation monitor with a low-

pressure rated radiation monitor. This change created an unreviewed safety

question. The safety issue created was that in the event of the design basis

accident, the primary containment would have been breached, personnel in

secondary containment would have been exposed to high radiation levels as they

exited, and reentry to secondary containment would have been delayed, and the

likelihood of radiation to the general public would be increased. The

violation is of concern because it indicates a lack of thoroughness in your

review process. At the exit meeting, your representative agreed that the

violation had occurred, but stated that the violation should be considered as

an non-cited violation in that your staff had identified the concern. We

9306150020 930609

PDR

ADOCK 05000298

1

G

pop

gi

J

l

U

_ _ _ _ _ _ - - _ _ _ _ _ _

i

.

,-

,

..

a

.

..

Nebraska Public Power District

-2-

agree that your staff had identified, in the week prior to our inspection, a

concern with meeting Appendix J "as is" testing requirements associated with

the modification. However, your staff had not formally halted the

installation of the modification, and moreover, was unable to show

documentation that it had identified that the modification would constitute a

significant safety issue.

In addition, on the day of the exit, your staff

identified that a nonconformance report on this matter had not been issued,

although new design changes were underway to rectify the originally faulted

.

'

design modification.

Consequently, we believe that the criteria for a non-

cited violation have not been met.

In regard to an unresolved item involving local leak rate testing of reactor

feedwater check valves, it is our understanding that, during the exit meeting

'

conducted on May 14, 1993, Mr. J. Meacham, Site Manager, made a commitment.

The commitment was to revise the Standard Clearance Order to incorporate the

use of the newly installed vents and drains for the local leak rate testing of

,

the reactor feedwater check valves. This revision should enable a consistent

testing methodology for these valves.

If your understanding of this

commitment differs from ours, please contact me immediately.

You are required to respond to this letter and should follow the instructions

specified in the enclosed Notice when preparing your response.

In your

i

response, you should document the specific actions taken and any additional

.

actions you plan to prevent recurrence. Wa request that your response

specifically address the circumstances associated with not having issued a

nonconformance report on the drywell ventilation radiation monitor prior to

initiating efforts to redesign this modification. After reviewing your

response to this Notice, including your proposed corrective actions and the

results of future inspections, the NRC will determine whether further NRC

'

enforcement action is necessary to ensure compliance with NRC regulatory

requirements.

In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of

this letter and its enclosures will be placed in the NRC Public Document Recm.

The responses directed by this letter and the enclosed Notice are not subject

to the clearance procedures of the Office of Management and Budget as required

by the Paperwork Reduction Act of 1980, Pub. L. No. 96.511.

Should you have any questions concerning this inspection, we will be pleased

to discuss them with you.

,

Sincerely,

I Ta-o

4

y - Samuel J. Collins, Director

g

,

Division of Reactor Safety

Enclosures:

(see next page)

P

__

.

c?.

A

Nebraska Public Power District

-3-

.

,

Enclosures:

1.

Appendix A - Notice of Violation

1

2.

Appendix B - NRC Inspection Report

50-298/93-18 w/ attachments

,

cc w/ enclosures:

Nebraska Public Power District

ATTN:

G. D. Watson, General Counsel

P.O. Box 499

Columbus, Nebraska 68602-0499

Cooper Nuclear Station

ATTN: John M. Meacham, Site Manager

.

P.O. Box 98

Brownville, Nebraska 68321

,

Nebraska Department of Environmental

Control

ATTN: Randolph Wood, Director

P.O. Box 98922

Lincoln, Nebraska 68509-8922

,

Nemaha County Board of Commissioners

,

ATTN: Richard Moody, Chairman

Nemaha County Courthouse

1824 N Street

Auburn, Nebraska 68305

.

Nebraska Department of Health

ATTN:

Harold Borchert, Director

Division of Radiological Health

301 Centennial Mali, South

P.O. Box 95007

Lincoln, Nebraska 68509-5007

Kansas Radiation Control Program Director

.

k

.

.

_

.

.

N

e

,,

Nebraska Public Power District

-4-

,

bcc distrib. by RIV:

J. L. Milhoan

Resident Inspector

DRP

Section Chief (DRP/C)

i

Lisa Shea, RM/ALF, MS: MNBB 4503

MIS System

DRSS-FIPS

Section Chief (DRP/TSS)

'

Project Engineer (DRP/C)

RIV File

Senior Resident Inspector - River Bend

Senior Resident Inspector - Fort Calhoun

D. Powers

C. Johnson

G. Sanborn

J. Pulsipher, NRR, SPLB

,

n

-

MSh

j[

D[k'pRh /

E([ /k

DrdP

'

D:DRS 9d

RIV:RI:

C:MS

p'

-

/4THo;vwel) ,

CSanborn

ABBeach

SJCollins

/

v;a

g

yn

CJohnson /l ty

DAPowers

f

If /24/93

.f/35/93

h/h93

(. //f /93

'/I'/93

/ / 7 /93

_-

.

.

.-

Nebraska Public Power District

-4-

bec distrib. by RIV:

J. L. Milhoan

Resident Inspector

DRP

Section Chief (DRP/C)

Lisa Shea, RM/ALF, MS: MNBB 4503

MIS System

DRSS-FIPS

Section Chief (DRP/TSS)

Project Engineer (DRP/C)

RIV File

Senior Resident Inspector - River Bend

Senior Resident Inspector - Fort Calhoun

D. Powers

C. Johnson

G. Sanborn

J. Pulsipher, NRR, SPLB

,

I

L

m

-

_

..

RIV:RI:MSk(

g[

DE)hRd / Ehd

DkRf

D:DRS 7d

C:MS

CJohnson/lk

DAPowers

[THbel[

GSNo'rn MkBeach

SJColl ds'

f /24/93

f/26/93

h/k93

(o/h/93

M f/93

/ ///93

/

4

!