ML20044H187

From kanterella
Jump to navigation Jump to search
Forwards GP-R-643-93-008, Limerick Generating Station Unit 2 Primary Reactor Containment Integrated Leakage Rate Test, Final Rept.Test Performed,As Scheduled in Mar 1993 During Second Refueling Outage
ML20044H187
Person / Time
Site: Limerick Constellation icon.png
Issue date: 05/27/1993
From: Helwig D
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20044H188 List:
References
NUDOCS 9306080040
Download: ML20044H187 (1)


Text

7 i

10CFR50, Appendix J PHILADELPHIA ELECTRIC COMPANY LIMERICK GENERATING STATION P. O. BOX 2300 SANATOGA, PA 19464-2300 (215) 327-1200, EXT. 3000 DAVID R. HELWIG VICE PRESIDENT Myy 2], }993 LIMERICK GENERATING STATION Docket No. 50-353 License No..NPF-85 U.S. Nuclear Regulatory Commission Attn: Document Control Desk

^

Washington, DC 20555

SUBJECT:

Limerick Generating Station, Unit 2 Reactor Containment Building Integrated Leak Rate Test Report Gentlemen:

Attached is the Limerick Generating Station, Unit 2 Reactor Containment Building Integrated Leak Rate Test (ILRT) Report for the ILRT performed as scheduled in March, 1993, during the Unit 2 second refueling outage.

This report is being submitted in accordance with the requirements of 10CFR50, Appendix J, Section V, Paragraph B.

If you have any questions or require additional information, please do not hesitate to contact us.

Very truly yours, t

/

DMS/cah Attachment cc:

T. T. Martin, Administrator, Region I, USNRC A

N. S. Perry, USNRC Senior Resident Inspector, LGS g

01 I g6dsookf^930527 p

ADOCK 05000053 PDR