Application for Amend to License NPF-49,revising Tech Spec Table 3.3-9 to Realign Column Headings for Min Channels Operable & Total Number of Channels & 4.3-6 to Make Monthly Channel Check Applicable Only When Below P-6 Setpoint
ML20044B171
Person / Time
Site: Millstone 
Issue date: 07/10/1990
From: Mroczka E
NORTHEAST NUCLEAR ENERGY CO., NORTHEAST UTILITIES
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20044B172 List:
References
B13550, NUDOCS 9007180031
Download: ML20044B171 (4)


Text

.,

[

s I>

EE' Osneral Offkes e Seldon Street, Berlin, Connecticut s;

2 b

fjnTrORD. CONNECTICUT 0614i4270 :

%0'0",T"0%1,

L t

(203) e65-sooo i

' July 10, 1990=

Docket No. 50 423 B13550 I

m Re:

10CFR50.90

U.S. Nuclear Regulatory Commission Attention
Document Control Desk Washington, DC 20555-Gentlemen:

W Millstone Nuclear Power Station, Unit No. 3 1

L Proposed Revision to Technical Specifications J

Remote Shutdown'Monitorina Instrumentation

'I Pursuant to 10CFR50.90,- Northeas.t Nuclear Energy Company (NNECO) hereby

-proposes to amend operating license NPF-49 by incorporating the changes' identified in Attachment-1 into the Technical Specifications of Millstone Unit

-No. 3.

g e

i L

Description of Prooosed Chanaes i

' Thel propossd change to Table 3.3-9 would realign the column headings for o

l

" Total No. of' Channels" and " Minimum Channels Operable."

There are no other~

ll '

, changes to Table 3.3-9.

This proposed change is.necessary to correct an E

administrative oversight that occurred during preparation of the initial 1

Millstone Unit No~. 3 Technical Specifications.

j l~

l The proposed change to Table 4.3-6 will make the monthly channel check for the-source' range nuclear instrument applicable only when below the P-6 interlock

. setpoint,.- The reason for this proposed change is that the source range n

nuclear instrument is not in service with the reactor at power.

During the

I

.i initial process of de No '3, NNEC0 proposedgoping the Technical Specifications for Millstone-Unit -

the addition of a footnote to Table 4.3-6 documenting that the channel check for the source range nuclear instrument is not applicable with power above P-6.

This change was never incorporated into the Mil.lstone Unit No. 3 Technical Specifications.

- The change proposed herein adds a footnote to item 14 of Table 4.3-6, Source Range Count Rate, specifying that the monthly channel check can only be 1

(1)

J. F. Opeka letter to B. J. Youngblood, Millstone Nuclear Power Station, Unit No. 3 Technical Specifications--Proof and Review, dated September 9, 1985.

O b OON $O0bok23

\\

P pdc 0\\

0 OS3422 REV. 4-88

/

i

.s

g-G<

g; C

U.S. Nuclear Regulatory Commission B13550/Page 2 July 10, 1990 1

performed when below the P-6 intermediate range neutron flux interlock setpoint.

The P 6 permissive is generated when either intermediate range i

channel is above 1 x 10 18 amps. This permissive allows the operator to block the. source range high flux reactor trip and deenergize the instrument during a normal reactor startup.

During a shutdown evolution, if both channels go below I x 10'10 amps, the source range detectors will be automatically a

energized.

A' channel check is the qualitative assessment of channel behavior during plant

[

operation by observation.

This determination involves the comparison. of indicated parameter values for each channel of a particular function.

It is l

based on the assumption that the channels indicated in the control room should l

read approximately the same.

If a channel is outside of the match criteria, it may be &n indication that the transmitter or the racks have drifted outside of their limit.

If-the channels are within the match criteria, it is a reasonable assumption that the channels are within specification.

If the channels are normally off-scale during plant operation, then the channel check will only verify that they are off-scale in the same direction.

Since the initial startup of Millstone Unit No. 3, the monthly surveillance (channel check) have been performed to verify that-the channels are off-scale (low) during plant operation.

Sianificant Hazards Consideration

,p NNEC0 has reviewed the proposed changes in accordance with 10CFR50.92 and has l

concluded that the changes do not involve a significant hazards consideration.

l The basis for this conclusion is that the three criteria of 10CFR50.92(c) are not compromised.

The proposed changes do not involve a significant hazards consideration because the changes would not:

1.

Involve a significant increase in the probability or consequences of an accident previously analyzed.

The proposed changes to Table 3.3-9 would correctly realign the column headings to reflect " Total 'No.

of Channels" and " Minimum Channels L.

Operable. " There are no other changes to Table 3.3-9, nor are there any changes in the way the plant is operated.

The proposed change is being made to correct an administrative oversight that occurred during preparation of the initial Millstone Unit No. 3 Technical Specifications.

The proposed change to Table 4.3-6 will more accurately reflect the surveillance requirements associated with the source range count rate I

instrument.

Since the instrument is only operable below the P-6

(

interlock setpoint, it is inappropriate to perform a surveillance on it during power operation.

These proposed changes will have no negative impact on the probability of occurrence of any design basis accident.

There are no safety systems associated with these proposed changes, nor are any failure modes affected by these changes.

I i

T

}

4[ 9, l*

t

}

i U.S. Nuclear. Regulatory Commission B13550/Page 3 July _10, 1990 2.

' Create the possibility of a new or different kind of accident from any previously analyzed.

The' proposed changes to Tables 3.3-9 and 4.3-6 are considered an improvement to the Millstone Unit No.

3 Technical Specifications.

The changes to Table 3.3-9 will correctly realign the column headings for

" Total No. of Channels" and " Minimum Channels Operable."

There are no other changes being made to this-table, i

The changes to Table 4.3-6 will more accurately reflect the surveillance f

requirements for the source range count rate nuclear instrument.

Since this instrument is only operable when below the P-6 interlock setpoint j_

-(zero power), it is inappropriate to perform a surveillance on it during i

power operation.

-l Since there are no changes in the way the plant is operated, the potential for an unanalyzed accident is - not created.

No new failure I

modes.are introduced, t

i:'

3.

Involve a significant reduction in a margin of safety.

Since the l

l proposed changes to Tables 3.3-9 and 4.3-6 do not affect the consequences l-of any-accident previously analyzed, there is no reduction in the margin l

of safety.

1 1

L In summary, for the reasons identified above, NNECO has concluded that l

- continued operation of the. facility in accordance with the proposed amendment would not involve a significant hazards consideration.

L Moreover; the Commission has provided guidance concerning the application of i

standards in 10CFR50.92 by providing certain examples (March 6,

1986, 51FR7751) of amendments that are considered not likely to involve a 1

significant hazards consideration.

Although the proposed changes are not L

enveloped by a specific example, the proposed changes would not involve a

)

(-

significant increase in the probability or consequences of an ar.cident previously analyzed.

The changes to Table 3.3-9 realign the column Madings l-for " Total No. of Channels" and " Minimum Channels Operable" to correct a typographical error that occurred during the initial preparation of the Millstone Unit No. 3 Technical Specifications.

The changes to Table 4.3-6 will more accurately reflect the surveillance requirements for the source l

1 range count rate nuclear instrument, which are only operable when below the L

P-6 interlock setpoint.

Since these instruments are only operable during zero power operations (below P-6) it is appropriate to perform a surveillance only during this time.

The proposed changes are intended to clarify the Technical p

Specifications and more accurately represent surveillance requirements.

l Based upon the information contained in this submittal and the environmental assessment for Millstone Unit No.

3, there are no radiological or nonradiological impacts associated with the proposed changes and the proposed l

l l

m w

g q,-

i U.S. Nuclear Regulatory Commission B13550/Page 4 y'

' July 10, 1990 license amendment will not have a significant effect on the quality of the human environment.

The Millstone Unit No. 3 Nuclear Review Board has reviewed and approved the.

attached proposed _ revisions and has concurred with the above determinations.

1' In accordance with'10CFR50.91(b), NNECO is_providing the State of Connecticut with a copy of this proposed amendment.

Regarding our proposed schedule for this amendment, we recuest issuance at your earliest convenience with - the amendment effective wit 11n 30 days upon issuance.

t Should you have any questions regarding the attached amendment request, please contact our licensing representative directly.

Very truly yours, NORTHEAST NUCLEAR ENERGY COMPANY l

h &AW E. J. MMigrka

//

Senior Vite President cc: Kevin McCarthy, Director Radiation Control Unit Department of Environmental Protection p

Hartford, CT 06116 T. T. Martin, Region ! Administrator D. H. Jaffe, NRC Project Manager, Millstone Unit No. 3 W. J. Raymond, Senior Resident Inspector, Millstono Unit No. 3 STATE OF CONNECTICUT)

) ss. Berlin COUNTY OF HARTFORD )

Then personally appeared before me, E. J. Mroczka, who being duly sworn, did i

state that he is Senior Vice President of Northeast Nuclear Energy Company, a j

Licensee-herein, that he is authorized to execute and file the foregoing information in the name and on behalf of the Licensee herein, and that the statements contained in said information are true and correct to the best of his knowledge and belief, 4Mbr m sa.

NbtaryPuFJTc My Comm!ssion' Expires March 31,1993

.