SAFETY EVALVATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATED TO AMENDPENT NOS.131 AND 106TO l

FACILITY OPERATING LICENSE NOS. DPR-51 AND NPF-6 l

ENTERGY OPERATIONS. INC.

ARKANSAS NUCLEAR ONE. UNIT NOS. 1 AND 2 DOCKET N05. 50-313 AND 50-368

1.0 INTRODUCTION

I l

By letters dated October 30,1987 as supplemented on September 27,1989 for Units 1 and 2 and January 29, 1990 for Unit 1 only. Arkansas Power and l

Light Company (AP&L) requested amendments to the Facility Operating i

License Nos. DPR-51 and NPF-6 for Arkansas Nuclear One, Units 1 and 2 (ANO-182). The proposed amendments would change the expiration dste i

for ANO-1 from December 6, 2008 to May 20, 2014, and for ANO 2 from

)

December 6, 2012 to July 17, 2018.

j 2.0 DISCUSSION Section 103.c of the Atomic Energy Act of 1954 provides that a license is l

to be issued for a specified period not exceeding 40 years. The Code of Federal Regulations in 10 CFR 50.51 specifies that each license will be l

issued for a fixed period of time not to exceed 40 years from date of issuance. Also, 10 CFR 50.56 and 10 CFR 50.57 allow the issuance of an j

operating license pursuant to 10 CFR 50.51 after the construction of the facility has been substantially completed, in conformity with the con-struction permit and when other provisions specified in 10 CFR 50.57 are

[

met. The currently licensed terms for Arkansas Nuclear One, Units 1 and 2

)

are 40 years commencing with the issuance of the construction permits (December 6,1968andDecember6,1972). Accounting for the time that was required for plant construction, this represents an effective operating license term of 346 years for each unit. Consistent with Section 103.c of

' the Atomic Energy Act and Sections 50,51, 50.56 and 50.57 of the Commission's regulations, AP&L, by its application of October 30, 1987, seeks extensions of the operating license terms for ANO-1&2 from the date of operating license issuance.

3.0 EVALVATION AP&L's request for extension v( the operating licenses is based on the fact that a 40-year service life was considered during the design and construction of the plant. Although this does not mean that some components will not wear out during the plant lifetime, design features were incorporated which maximize the inspectability of structures, systems and equipment.

Surveillance and maintenance practices which were implemented in accordance with the ASME code and the facility Technical Specifications provide assurance that any unexpected degradation in plant i

equipment will be identified and corrected.

9007170235 900706 DR ADOCK 0500 3

i [

3.1 Mechanical Equipment The original Safety Analysis Reports for ANO-182 as approved by NRC's Safety 1. valuation Reports, have evaluated the adequacy of safety-related i

mechanical systems, equipment, and components for 40 years of plant operation.

It is clear that the design of the plant considered a 40-year service life. Where a specific design lifetime is specified in the Safety Analysis Report it is at least 40 years (i.e. 32 EFPY at 80f capacity factor). Examplesincludethedescriptionofthereactorpressurevessel, reactor coolant system components, and control element drive mechanisms.

In other cases, performance requirements govern the design and no specific design lifetime is stated.

Although some mechanical equipment and components might wear out or need replacement during the plant operating lifetime, existing surveillance and n.ainttnance programs are sufficient to r,aintain or determine the need for replacement of safety related components.

Periodic inservice inspection and testing requirements have been incorporated into procedures to provide the added assurance that any unanticipated degradation in systems or equipment will be identified and corrected in a timely manner. Therefore, the staff concludes that safety related mechanical systems, equipment, and con.ponents considered will not be impacted by a 40-year operating lifetime, d

l 3.2 Electrical Equipment

)

I The staff has also evaluated the safety implications of extending the l

t l

ANO-1&2 operating license on safety-related electrical systems and equipment. This evaluation considered AP&L's review of extended service i

life irpacts on equipment, integrated dose qualifications and environmental qualifications in response to 10 CFR 50.49.

For safety-related electrical equipment within the scope of 10 CFR 50.49, a g reviews have been conducted by AP&L so as to establish a qualif life for the equipment.

l For this equipment, the staff believes that the licensee has controls in place to ensure that required surveillance and maintenance are performed.

These are described in the Environmental Qualification Program Manual and ANO procedures. The current AP&L Equipment Qualification uEQ)programis in con.pliance with 10 CFR 50.49. There are currently no known open EQ l

l issues which are affected by the extension of the operating license.

Based on this evaluation, the staff concludes that electrical systems design, electrical equipment selection and application, and environmental qualification of electrical equipment either considered the effects of a 40-year operational lifetime or will not be affected by a 40-year operational lifetime.

l

l,

3.3 Retetor Vessel integrity The ANO 1 reactor vessel was designed considering(the effects of 40 years of operation with a plant capacity factor of 80% 32EFPY). The B&W Owners Group (BWOG) Integrated Reactor Yessel Material Surveillance Program and the Cavity Dosimetry Program provide the means to continuously senitor the cumulative effects of neutron exposure on reactor vessel materials through 32 EFPY. The analyses of four ANO-1 plant specific surveillance capsules, which were irradiated at Davis Casse, are documented in the following 1984),andBAW-2075(May1989)).

BAW-1440 (April 1977 ; BAW-1698 (Novenher 1981); BAW-1836 W uly reports:

Specificallyforthemogrecepttest,thecapsulereceivedanaverage fast fluence of 1.46X10 n/cm (E greater than 1.0 MeV).

Based on the calculated fast flux at the reactor vessel wall, an 801 load factor, and the planned fuel management, the projected fast fluence that the ANO-1 reactorvesselinsidygsurfage will receive in 40 calendar years of operation is 9.75X10 n/cm (E greater than 1.0 MeV).

1hese reports conclude that the current analytical techniques used for praticting the change in both the increase in RT @ and the decrease in upper-shelf toughness properties are conservativ In addition, the results indicate that the reactor vessel materials exhibited nomal changes in tensile strength from exposure to neutron fluence. These analyses show that the expected cumulative neutron fluence on the ANO-1 reactor vessel will not be a limiting consideration for 32 EFPY of plant operation.

Completion of the BWOG Integrated Reactor Yessel Material Surveillance Program will ensure compliance with 10 CFR Part 50, Appendices G and H, through 32 EFPY.

The method of Regulatory Guide 1.99, Rev. 2, predicts a decrease in the Charpy upper-shelf energy to below 50 ft-lbs for the controlling weld metal at the vessel inside wall.

However, using surveillance data and the prediction techniques presented in BAW-1803, AP&l. calculated that none of the reactor vessel material (including the most limiting weld metal) upper-shelf energies will decrease to below 50 ft-1bs during the vessel desigre life. The uncertainties of the procedures used to evaluate the materials' upper-shelf energies necessitated that a fracture analysis be performed on the most limiting weld nietal. This low up~ser-shelf elastic-plastic toughness analysis of the controlling weld in tie ANO-1 reactor vessel is provided in Section 9 of BAW-2075. The analysis used the methodology documented in B8W Topical Report BAW-10046A, Rev. 2.

The NRC approved the B&WOG analysis procedures in 1986. The low upper-shelf fracture analysis demonstrated that the most limiting weld metal has adequate irradiated toughness properties to assure safe operation to 32 EFPY.

The results of the tension tests indicated that the materials exhibited normal behavior relative to neutron fluence expo wre. The Charpy impact data results exhibited the characteristic increase in transition temperature and decrease in upper-shelf energy. These results demonstrated that the current techniques used for predicting the change in both RT and NDT

i

, upper-shelf properties due to irradiation are conservative. The B;W recommended operating period was extended to 32 EFPY as a result of the fourth capsule evaluation. These new operating limitations are in accordance with the requirements of Appendix G of 10 CFR Part 50. AP&L plans to submit new pressurization, heatup and cooldown limit curves in 1990 based on the results of the fourth capsule examination.

AP&L also plans to install neutron dosinetry in the ANO-1 cavity in 1990 to meet Appendix H monitoring requirements. This dosinetry will be t

consistent with the B&W Owners Group Dosimetry Program, as described in BAW-1875.

As required by 10 CFR 50.61, AP&L has submitted to the NRC the projected values of RT for ANO-1 reactor vessel materials through the end of the currentliceEl$andthrough32EFPY. This submittal included results derived from the B&W Owners Group Report BAW-1895, " Pressurized Thermal Shock Evaluations in Accordance With 10 CFR 50.61 for BWOG Reactor Pressure vessels," dated January 1986. Table 4-6 of the referenced report shows that the RT for all ANO-1 reactor vessel materials is well within the NRCscreeniEh6 criteria through both the current license term, and 32 EFPY.

The most limiting material is the middle circumferential weld WF-112, which will have an RT of 251*F upon expiration of the current i

of264*FIktheendof32EFPY. These values are p

license and an RT below the 10 CFR E 61 screening criteria of 300'F for circumferential welds. As required by the NRC Safety Evaluation for the ANO-1 PTS evalua-4 tion AP&L is required to submit a revaluation of RT and comparison i

withthepredictedvaluewithfuturepressure-temperElbresubmittalsas

+

per 10 CFR Part 50, Appendix G.

The ANO-2 reactor vessel was also designed considering the effects of 40 years of operation at a plant capacity factor of 80% (32 EFPY). The reactor Yessel Material Surveillance Program for ANO-2 contains six in-reactor surveillance capsules that are used to monitor cumulative i

effects of power operation on reactor vessel materials. This program ensures that the ANO-2 reactor vessel will meet the requirements of 10 CFR Part 50, Appendices G and H through 32 EFPY.

-All the reactor vessel materials are predicted to have a 1cw susceptibility r

to neutron radiation damage because of their high unirradiated charpy V-notch urper shelf energy, and their low copper, phos)horous and nickel content. The results of the first capsule analysis, W11ch were documented in a Battelle Columbus Laboratory Report dated May 1,1984 supported the-predictionthatcumulativeneutronfluencewillnotbeaIlmitingconsideration forreactorvesseloperationthroughfulldesignliffg Thegeresults indicated that at a fast neutron fluence of 3.5 X 10 n/cm, base metal longitudinal specimens had the largest reduction in upper shelf energy.

This reduction was from 155 ft-lb to 142 ft-lb, which is still substantially higher than the 50 ft-lb criteria of 10 CFR Part 50, Appendix G.

Additional surveillance capsules are scheduled to be removed and analyzed to further characterize irradiation-induced property changes for the ANO-2 reactor vessel over the 32 EFPY.

i

.. As required by 10 CFR 50.61, AP&L has determined projected values of RT' for the ANO-2 reactor vessel materials. The results of this analysis s'Etted to the NRC on January 22,1986, showed that the RT for each materialintheANO-2reactorvesselwasbelowtheNRCscreebbgcriteria i

through the current 1! cense and through 32 EFPY. The most limiting-i material was intermediate shell plate, heat number C8161-3, which will 1

have an RT of 173' upon expiration of the current license and a RT of 179.6'F N the end of 32 EFPY. These values are well witnin the 103FR P

50.61 screening criteria of 270'F for plate materials. The NRC review of 1

the AP&L 10 CFR 50.61 submittal found the material properties of reactor J

vessel beltline materials, the projected fluence at the inner surface of the reactor vessel for the end of life of the plant and the calculated RT for the end of life of the plant to be accestable. The NRC Safety EvU6ationdatedJuly 20, 1987, value of 179.6*F alsofoundthattieRT{$1chisbeyondthe P

for the limiting plate material at the end of 32 EFPY currentexpirationdateofthelicensetobeacceptable. As required by the NRC Safety Evaluation for the ANO-2 PTS evaluation, AP&L will submit a reevaluation of RT and comparison with the predicted value with future pressure-temperatuNSsubmittals as per 10 CFR Part 50, Appendix G.

We conclude that there are no special considerations to indicate reactor vessel degradation for Arkansas Nuclear One, Units 1 and 2 due to the proposed operating lifetime extensions. The structural integrity of the reactor vessels is' assured because each vessel was originally designed for 32 EFPY usage (40 years at 80% plant capacity); each is monitored, inspected, and tested to detect degradation processes at an early stage of development; and each unit is operated with procedures to assure that design conditions are not exceeded.

3.4 Structures for ANO-1 and ANO-2, the auxiliary and turbine buildings and intake 1

structures are constructed of reinforced concrete and structural steel.

The reactor building (ANO-1) is a steel-lined, post-tensioned and reinforced concrete structure. Thecontainment(ANO-2)isalsoasteel-lined, post-tensioned and reinforced concrete structure.

Industrial experience with such materials establishes that a service life well in excess of forty (40) years can be anticipated.

Surveillance, inspection, building / containment structures so that anyand testing condition of the reactor degradation can be identified and corrected.

In particular the ANO-1 reactor building and the ANO-2 containment integrated leak rate test (ILRT) performed at least three times every 10 years, verifies the leak tightness of these structures throughout their service life.

Surveillances of the post-tensioning system are also provided which further verify reactor building / containment integrity.

From the results of tendon surveillances so far performed for the reactor building / containment, there is the possibility that some of the tendon forces may go below the minimum required values if the operating license terms are extended from the date of l

operating license issuance. This condition is to be identified and l

rectified as required by the facility technical specification on tendon surveillance.

j i

~

3.5 Elevated Peactor Building Temperatures (ANO-1?,

The reactor building air temperature nas been higher than expected throughout the operating history of ANO-1. Since 1974, this has been, and continues to be, the subject of investigative and corrective actions. The Justification for Continued Operation (JCO), submitted to the NRC on August 27, 1987 described the results of a comprehensive evaluation of safety implications of the elevated reactor building temperature. The evaluation included a detailed review of the plant's design basis, accident analysis, structural performance, system and equipment performance, and equiment qualification.

The JC0 concluded that operation with elevated reactor auilding temperatures has no significant adverse effects on plant components, systems, and structures, nor on overall safety or the plant's response to postulated accidents and transients.

Furthermore, AP&L has committed to develop a long term action plan. Actions will be oriented toward two areas: further evaluation of elevated tempera-ture effects; and reduction of reactor building bulk average temperature.

Long term inspections, preventative maintenance, and replacement intervals for structures and systems adversely affected by past and future reactor building temperatures will be modified as necessary to provide assurance that their performance during normal and transient conditions is as required to ensure safe operation of ANO-1.

During 16te 1988, AP&L informed the NRC of a self-imposed operating limitation upon ANO-1, based on AP&L's discovery of reduced service water flow, and otier discrepancies which could have reduced the post LOCA long-term containment cooldown and therefore call into question the qualification of safety-related equipment located in the containment.

These deficiencies were identified during the ANO-1 eighth refueling outage (IR8) and reported per 10 CFR 50.73 on March 30 1989. Analysis wasperformedduringtheIR8outagewhichsupportedfullpoweroperation for Lake Dardanell temperatures up to 70*F. Operation of ANO-1 with lake temperature in excess of 70'F was precluded at that time pending further evaluation of the discrepancies.

AP&L's analysis of the effects of the reduced service water flow and the other identified discrepancies was completed in early April 1989. AP&L evaluated the effects of the identified deficiencies with respect to the post LOCA containment temperature response and had determined that the lant could be operated at full power with lake temperature u;: to 95'F p(maximumanticipatedlaketemperature)withoutinvalidatingtheenvironmental qualification of the equipment contained in the Reactor Building.

The staff has had followup discussions with AP&L concerning the analysis and AP&L provided an additional submittal dated July 19, 1989. The staff has completed its review of AP&L's analysis and justification for full power operation with lake water temperatures up to 95'F and has found them to be acceptable. A safety evaluation is being prepared for issuance to reflect this.

-7 l

The staff believes that the extension of the operating license does not affect the results of the JC0 evaluations.

Plant operation is based on an ongoing process of monitoring, inspection, evaluations, and maintenance to assure acceptable operability, and safety. Programs such as Technical Specification surveillance, inservice inspection, and equipment qualification provide this assurance regardless of the duration of the operating license.

3.6 Sumar.y of Findings i

The NRC staff concluded in the Environmental Assessment that the annual radiological effects during the additional years of operation that would l

be authorized by the proposed license amendments are not more than were previously estimated in the Final Environmental Statements, and are acceptable.

The staff concludes from its considerations of the design, operation, i

testing and monitoring of the mechanical equipment, structures, and the reactor vessels that an extension of the operating licenses for Arkansas Nuclear One, Units 1 and 2 to a 40-year service life is consistent with the FSARs, SERs, and submittals made by the AP&L, and that there is reasonable assurance that the units will be able to continue to operate safely for the additional periods authorized by the amendments. The plants are operated in compliance with the Comission's regulations, and issues associated with plant degradation have been adequately addressed.

J In sumary, we find that extension of the operating licenses for ANO-142 to allow 40-year service lives is consistent with the Final Environmental Statements and Safety Evaluation Reports for the units and that the Comission's previous findings are not changed.

4.0 Environmental Consideration A Notice of Issuance of Environmental Assessment and Finding of No i

Significant Impact relating to the proposed extension of the Facility

.0perating License termination dates for Arkansas Nuclear One was published in the Federal Register on 5.0. Conclusion b

The staff has concluded, based on considerations discussed above, that:

(1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner and (2)suchactivitieswillbeconductedincompliancewiththeCommIssion's regulations, and the issuance of the amendments will not be inimical to the common defense and security or to the health and safety of the public.

Date: July 6, 1990 Principal Contributors: Chester Poslusny, PDIV-1 Tom Alexion, PDIV-1 4

-