Environ Assessment & Finding of No Significant Impact Re 900108 Application,As Clarified on 900320 & 0420 Concerning Exemption to Grant one-time Relief from Requirements of 10CFR50,App J to Perform Type C Test within 2-yr Interval
ML20043H223
Person / Time
Site: Surry 
Issue date: 06/20/1990
From: Berkow H
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20043H224 List:
References
NUDOCS 9006220262
Download: ML20043H223 (4)


Text

__

f*

7590-01 UNITED STATES NUCLEAR REGULATORY COMMISSION VIRGINIA ELECTRIC AND POWER COMPANY DOCKET N0. 50-280-ENVIRONMENTAL ASSESSMENT AND FINDING 0F NO SIGNIFICANT IMPACT The U. S. Nuclear Regulatory Comission (the Comission) is considering the issuance of an exemption from the requirements of Appendix J to 10 CFR Part S0 to Virginia Electric and Power Company (the licensee) for the Surry Power Station, Unit No.1, located in Surry County, Virginia.

ENVIRONMENTAL ASSESSMENT L

Identification of Proposed Action:

The proposed exemption would grant a one-time relief from the schedular requirements of 10 CFR Part 50, Appendix J, paragraph III.D.3 to perform a Type C test within a 2-year interval.

In addition, related changes to the

. Technical-Specifications would be made. The requested exemption would allow the licensee to defer the Type C testing until the next refueling outage scheduled for early October 1990, but no later than December 31, 1990.

The. licensee's request for exemption and bases therefore are contained in a letter dated January 8,1990, as clarified on March 20 and April 20, 1990.

t E

The Need for the Proposed Action:

The proposed exemption would allow a one-time relief from performing a

. Type C test currently required to be performed no later than June 23, 1990, and enable Surry Unit 1 to continue normal plant operation and therefore

. prevent the premature shutdown of the Surry Power Station, Unit 1.

t 4

9006220262 900620 PDR ADOCK 0500 0

P i

m.

c.

.l

'l

+s

. \\

The purpose of the Type C testing is to measure and ensure that the l

leakage through the primary reactor containment does not exceed the maximum-i allowable leakage rate.

It also provides assurance that periodic surveillance, maintenance and repairs are made to systems or components penetrating the containment. During the last two Type C tests, the licensee took corrective actions for valve repair and valve replacement to reduce valve leakage.

In i

addition, the licensee has provided projected valve leakage estimates which the NRC has reviewed. The staff finds that the methodology used for estimating the leakage for the extended period is acceptable.

Environmental Impacts of the Proposed Action:

The proposed exemption would allow a one-time relief from the schedular L

requirements to perform a Type C test within a 2-year period. The licensee has taken corrective action to repair valves and replaced certain valves i

during the.last two Type C tests to minimize valve leakage. The proposed exemption will not negatively impact containment integrity and will not i

significantly change the risk from facility accidents. Therefore.

l-post-accident radiological releases will not be significantly greater than i

previously determined.nor does the proposed exemption otherwise affect l

radiological plant effluents, or result in any significant occupational exposure. Likewise, the proposed exemption would not affect nonradiological i

plant effluents and would have no other environmental impacts. Therefore, the l

staff concludes that there are no significant radiological or nonradiological u

l_

environmental impacts associated with the proposed exemption.

l l

1 i

r w,

.1 Alternatives to the Proposed Action:

Because it has been concluded that there are no measurable impacts associated with the proposed exemption, any alternative to the exemption will have either no environmental impacts or greater environmental impacts.

The principal alternative would be to deny the requested exemption.

Such action would not reduce environmental impacts of the Surry Unit 1 operations i

and would result in reduced operational flexibility.

Alternative Use of Resources:

q This action does not involve the use of resources not previously considered in the Final Environmental Statement for the Surry Power Station, Unit 1.

Agencies and Persons Consulted:

The NRC staff has reviewed the licensee's request and did not consult other agencies or persons.

FINDING OF NO SIGNIFICANT IMPACT The staff has determined not to prepare an environmental impact statement for the proposed exemption.

Based upon the foregoing environmental assessment, we conclude that the proposed action will not have a significant effect on the quality of the human environment.

For further details with respect to this action, see the application for exemption from 10 CFR Part 50, Appendix J, dated January 8,1990, as clarified on March 20 and April 20, 1990, which are available for public inspection at the Comission's Public Document Room, 2120 L Street, N.W.,

1

I\\.s-s

. c. :. r,

,s

.4

., Washington, D.C., and at the Swem Library, College of William and Mary, i

Williamsburg, Virginia.23185.

Dated at Rockville, Maryland, this 20th day of June 1990.

FOR THE NUCLEAR REGULATORY COMMISSION'

  • fbs,(

v.Ct -

( erbert N. Berkow, Director Project Directorate 11-2 Division of Reactor Projects-I/II Office of Nuclear Reactor Regulation i

1, 5' '

l

'\\

y.

(1;'

"