w June 15 1990 bocket No. 50-382 Mr. Ross P. Barkhurst Vice President-Nuclear Entergy Operations, Inc.
Post Office Box B Killona, Louisiana 70066 1
Dear Mr. Barkhurst:
1
SUBJECT:
-SHUTDOWN COOLING LEVEL INDICATION SYSTEM TAPS (TAC NO. 69791) i i
By letter dated May 21,199'), Louisiana Power and Light Company requested approval'for a common tap iocation for the Reactor Coolant Shutdown Level Measurement System (RCSLMS) and the Refueling Water Level Indication System (RWLIS).. The existing kWLIS uses a two-inch pipe from the Hot Leg 1.
It is proposed that the RCSLMS use this same two-inch pipe as a common header (or j
tap) for the RCSLMS.
i We have reviewed your request and the means by which Waterford 3 will ensure l
no blockage of the two-inch header. These involve pre-operational testing i
each time the systems are brought into service, additional testing during any extended operation at constant reduced inventory level, and a dedicated reactor operator on station to continuously monitor RCS level and temperature.
We agree that these measures should provide the assurance needed to monitor the RCS conditions and ensure against any effects of blockage in the common I
header. Therefore, the use of the existing two. inch line currently providing RWLIS_ indication is acceptable as a common header or tap for the two systems.
i Sincerely, IN David L. Wigginton, Acting Director Project Directorate IV-1 g
Division of Reactor Projects. III, IV, V and Special Projects Office of Nuclear Reactor Regulation cc: See next page l
DISTRIBUTION 1
Docket File NRC &-Local PDRs PD4 1 r/f D. Crutchfield G. Holahan P. Noonan D. Wigginton OGC E. Jordan RSB ACRS (10)
.PD4-1 Plant File y
0FC :PD4-1/l g PD4-
- RSE-D4-1/D(A)
..............J.I(::
HAME :PNoonan
- DWi on DATE:06/Q90
- 06//d/90
- 06//
90
- 6/ /90 OFFICIAL RECORD COPY Document Name: WATERFORD TAC 69791
[
0 9006210346 900615 PDR ADOCK 05000382 p
PDC h
. /puog 'o,,.
UNITED STATES f
3 g
NUCLEAR REGULATORY COMMISSION j
7.
...E WASHING TON, D. C. 20555 o,
June 15,1990
,,,g Docke'; he. 50-382 F.r. Ross P. Barkhurst Vice President-Nuclear Entergy Operations, Inc.
Port Office Box B Killona, Louisienn 70066
Dear Mr. Barkhurst:
SUBJECT:
SHUTDOWNCOOLINGLEVELINDICATIONSYSTEMTAPS(TACNO.69791)
Dy. letter dated May 21, 1990, Louisiana Power and Light Company requested approval for a common tap location for the Reactor Coolant Shutdown Level Meesurement System (RCSLMS) and the Ref ueling Water Level Indication System (RWLIS). The existing RWLIS uses a two-inch pipe from the Hot Leg 1.
It is proposed that the RCSLMS use this same two-inch pipe as a common header (or =
tap) for the RCSLMS.
We have reviewed your iequest and the means by which Waterford 3 will ensure no blockace of the two-inch header.
These involve pre-operational testing each time the systems are brought into service, additional testing during any extended operation at constant reduced inventory level, and a dedicated' reactor operator on station to continuously monitor RCS level and temperature.
We agree that these measures should provide the assurance needed:to monitor the RCS conditions'and ensure against any effects of blockage in the common header.
Therefore, the use of the existing two-inch line currently providing RWLIS indication is acceptable as a common header or-tap for the two systens.
Sincerely,
.1 m David L. Wiggi ton, Acting Director Project Directorate IV-1 Division of Reactor Projects.- Ill, IV, V and Special Projects Office of Nuclear Reactor Regulation cc: See next page l
l l-
)
1 i:
l
c Nr. hoss P. Barkhurst Waterford 3
- Entergy Operations, Inc, cc:
W. Malcolm Stevenson, Esq.
Regional Administrator, Region IV Itonroe & Leman U.S. Nuclear Regulatory Commission 201 St. Charles Avenue, Suite 3300 Office of Executive Director for New Orleans, Louisiano 70170-3300 Operations 611 Ryan Plaza Drive, Suite 1000 Mr. E. Blake
-Arlington, Texas 76011-Shaw, Pittman, Potts & Trowbridge 2300 N Street, NW Mr. William H. Spell', Administrator Washington, D.C.
20037 Nuclear Energy Division Department of Environmental Quality Resident inspector /Waterford NPS Post Office Box 14690 Post Office Box 822 Baton Rouge, Louisiana 70898 K111ona, Louisiana 70066 President,. Parish Council-Mr. Gerald W. Muench St. Charles Parish Vice-President, Operations Hahnville, Louisiana 70057 Support Entergy Operations, Inc.
Mr. Donald C.;Hintz P. O. Box 31995 Executive Vice President and Jackson, Mississippi 39286 Chief Operating.0fficer Entergy Operations, Inc.
William A. Cross P. 0. Box 31995 Bethesda Licensing Office Jackson, Mississippi 39286 3 Metro Center Suite 610 Chairman-Bethesda, Maryland 20814 Louisiana Public Service Commission
=0ne American Place, Suite 1630 Mr. Robert B. McGehee Baton Rouge, Louisiana '70825-1697 Wise, Barter, Child & Caraway P. O. Box 651 Mr..R. F. Burski Jackson, Mississippi 39205 Nuclear Safety & Regulatory Affairs l
Entergy Operations, Inc.
Mr..'J. R. McGaha, Jr.
317 Baronne Street Plant Manager
.New Orleans, Louisiana 70112 Entergy Operations, Inc.
P. O. Box B Mr. L. W. Laughlin, Site Licensing K111ona, Louisiana 70066 I
Support Supervisor _
I.
Entergy Operations, Inc.
P. O. Box B Killona,-Louisiana 70066 l
l 1
-