Notice of Violation from Insp on 900220-0402.Violation Noted:Two Maint Workers Made Two Entries Into Unit 2 Torus Room W/O Complying W/Special Instruction 5 of Radiation Work Permit
ML20043A753
Person / Time
Site: Peach Bottom Constellation icon.png
Issue date: 05/15/1990
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20043A751 List:
References
50-277-90-06, 50-277-90-6, NUDOCS 9005230080
Download: ML20043A753 (2)


Text

J y1 2. -,,_j D

APPENDIX A NOTICE OF VIOLATION Philadelphia Electric Company Docket No.

50-277 Peach Bottom Atomic Power Station License No. DRP-44 Unit No. 2 The inspection conducted on February 20 through April 2, 1990, identified the following violations, characterized according to the " General Statement of Policy and Procedure for NRC Enforcement Actions," 10 CFR Part 2, Appendix C (Enforcement Policy):

A.

Technical Specification 6.8.1 requires that written procedures shall be established, implemented, and maintained that meet the requirements of Appendix Alof Regulatory Guide 1.33 (November 1972). Regulatory Guide 1.33, Appendix A, requires implementation of radiation work permit (RWP) procedures.

Administrative procedure A-107, " Radiation Work Permit Program," estab-lishes the RWP program, and Step 5.5 requires that individuals comply with the provisions of the RWP.

A.1 Radiation work permit 2-90-054200 required in special instruction 5 that individuals making entry-to the Unit 2 torus room shall wear an alarming dosimeter and have positive health physics coverage.

Contrary to the above, on March 27, 1990, two maintenance workers-made two entries into the Unit 2 torus room, a posted high radiation area, without complying with special instruction 5 of the Radiation Work Permit.

A.2 Radiation Work Permit 2-90-5491 required in the special instructions that individuals breaching or clearing sample lines to the waste surge tanks wear a filter respirator, a surgeon's cap, top zipper and hood openings, and inform the controlling health physics technician of the breach so that he could be present.

Contrary to the above, on March 28, 1990, four workers breached the sample line to the waste surge tank and cleared the line with nitro-gen gas without complying with the special instructions on the Radi-ation Work Permit in that they did not inform health physics prior to breaching the system, and did not comply with the dress requirements.

This is a Severity Level IV Violation (Supplement IV).

OFFICIAL RECORD COPY IR PB 9006 - 0004.0.0 05/08/90 9005230080 900515 PDR ADOCK 0500027'7 O

PDC

[

Q,'.i. f ' '

sg

{

Appendix A-2 B.

Technical Specification 6.8.1 requires that written procedures and admini-strative. policies shall be established, implemented, and maintained that meet the requirements of Sections 5.1 and 5.3 of ANSI N18.7-1972 and Appendix A of Regulatory Guide 1.33 (November 1972).

Section 5.1.5 of

' ANSI N18.7-1972 requires procedures for control measures such as locking to secure and identify equipment in a controlled status. Appendix A of Regulatory Guide 1.33, Section A.3, also requires equipment control ad-ministrative procedures (e.g., locking).

Administrative procedure A-8, " Control of Locked Valves," Revision 6, Section 7.1.3 requires the requestor to complete a locked valve request, receive shift management approval for each-locked valve to be manipulated, inform the control room operator of the planned manipulation and to obtain the applicable locked valve' key from the control room key cabinet.

1 B.1 '. Contrary to.the above, on February 15, 1990, while performing ST 6.16, " Motor Driven Fire Pump Operability Test," Revision 12, a non-licensed operator manipulated three locked manual valves (HV-0-37C-12443, 12444, and 12345) without obtaining locked valve requests, shift management approval, and a locked valve key in accordance with procedure A-8.

As a result the locking device for HV-0-370-12444 was not re-applied following the test.

B.2 Contrary to the above, on March 19, 1990, while conducting work under 4

maintenance request form 9001918, a test engineer unlocked and

{

manipulated locked' manual valves HV-2-33-21078A and 21078B (reactor i

core isolation cooling system "A" and "B" room cooler inlet block valves) without obtaining locked valve requests and shtft management approval as required by procedure A-8.

This is a Severity Level IV Violation (Supplement I).

Pursuant to the provisions of 10 CFR 2.201, Philadelphia Electric Company is hereby required to submit to this office within thirty days of the date of the letter which transmitted this Notice, a written statement'or explanation in reply, including: (1) the corrective steps which have ben taken and the results achieved; (2) corrective steps which will be taken to avoid further violations-and.(3) the date when full compliance will be achieved. Where good cause is j

shown, consideration will be given to extending this response time.