ML20043A577

From kanterella
Jump to navigation Jump to search
Advises That 900208 Rev 26 to Radiation Emergency Plan Meets Planning Stds of 10CFR50.47(b) & Requirements of App E to 10CFR50,except for Comparison of Duties of Shift Technical Advisor & Core/Technical Support Person
ML20043A577
Person / Time
Site: Summer 
Issue date: 05/16/1990
From: Dan Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Bradham O
SOUTH CAROLINA ELECTRIC & GAS CO.
References
NUDOCS 9005220268
Download: ML20043A577 (5)


Text

%

m-y

+. k.ac.N 3+;

- 1%Y 161990 p

s Docket No. 50-395 JLicense No. NPF-12 iSouth Carolina Electric & Gas Company ATTN: ' Mr. O. S. Bradham

.. Vice President, Nuclear Operations

-Virgil C. Summer Nuclear Station P. O. Box 88

.Jenkinsville, SC '29065 Gentlemen:

SUBJECT:

VIRGIL C. SUMMER RADIATION EMERGENCY. PLAN, REVISION 26:

We have1 completed our review of Revision 26 to your. Virgil C. Summer Radiation 1

.EmergencyL Plan dated February 8,1990.

Based on our review, we have concluded that,. except for the items identified in Enclosure 1, the changes meet the

planning standards of 10 CFR 50.47(b) and the requirements of Appendix E _to-10 CFR-50.-

J q

We understand _that during a _ telephone conversation between Mr. Glen Salyers_of-

'the NRC and Mr. ' Mark: Counts of South Carolina Electric & Gas Company, your

-staff = agreed to incorporate. promptly. the items identified in the Enclosure -

--into the V. C. ' Summer Emergency' Plan. :If your understanding of' this.co'mmitment 1

differs from that outlined in the Enclosure, please contact-our office.

-In addition, Revision-26 also changed the augmentation requirement for Core Technical Suppor.t position.

The augmentation. time for this position is now 1** _in.30 minutes, where 1** indicates that the position may be provided by shift -personnel assigned other functions,.rather than the previous 1 in

'30. minutes.

In order to ' fully evaluate the. adequacy of. this change the

'following information should be provided to this office promptly:

l 1.

A comparison of the _ duties and responsibilities of the Shift Technical Adviser and-the Core, Technical Support person..

_j 2.

A comparison of the specific training and educational requirements of

<the Shift Technical idviser and the Core, Technical Support person.

3.

Additional trainins if any, that will be provided the Shift Technical Adviser enabling him to qualify as 'a Core, Technical Support person.

4.-

Demonstrate that any responsibilities that can not be performed or.

may be hindered in the performance of, while acting as Core, Technical Support person, can be performed by someone else on shift.

The need for this information was discussed with Mr. Mark Counts of your staff on May 7, 1990..

9005220268 900516 DR ADOCK 05000395 "Oj

y [n

.; +--

u South Carolina Electric & Gas Company 2

Should1 you have any questions regarding this letter, 'please contact Mr. William H. Rankin of our staff at 404-331-5618.

Sincerely.

OWGINALSIGNED BY WM !!AM H. RANK!N Douglas M. Collins, Chief Emergency Preparedness and Radiological Protection Branch Division of Radiation Safety and Safeguards

Enclosure:

. Tables 4-1 and 5-1 cc w/ enc 1:

-J.- L. Skolds, General Manager Nuclear Plant Operations Summer Nuclear Station-P. O. Box 88 (Mail Code 300)

Jenkinsville, SC 29065 A.: R. Koon, Jr., Manager Nuclear Licensing Summer. Nuclear Station-

'P. O. Box 88 (Mail Code 612)

Jenkinsville, SC 29065 J. B. Knotts, Jr.

Bishop, Cook, Purcell & Reynolds 1400 L Street NW Washington, D.

C..

20005-3502 1

R. "V. - Tanner Executive-Vice President South Carolina Public Service Authority 4

P. O. Box 398 Moncks Corner, SC 29461-0398 i

Chairman, Fairfield County Council P. O. Box 293 i

EWinnsboro, SC 29180 i

Attorney General Box 11549 Columbia, SC 29211-(cc w/ enc 1: Cont'd on page 3)

y y-m n.

'I [l4

.' 4 4l t

V L

I;b LSouth Carolina Electric & Gas Company.

'3 I<

p

('cc w/ encl;. cont'd)-

Heyward G. Shealy, Chief-r..

Bureau of Radiological Health B

1 South Carolina Department of Health

.and Environmental: Control 2600 Bull Street 9

Columbia,-SC-' 29201 L bcc w/ enc 1:?/.~J. Hayes,NRRl..

P c.

[y '.

VDocument Control Desk

.NRC Resident Inspector U.S.. Nuclear ~ Regulatory Commission-Route 1, Box 64 Jenkinsville, SC. 29065

}

4

. i i

.E% 2 4

t I

1 RII:D RII:DRSS RII:')RP

=+

r.

G5 yers R

.NCNtrell 5/$'90 5ff/90' 5/3/90

/

P I_4 m

g o

jM.'

c,x o

i 1

ENCLOSURE t

TABLE 4-1 EMERGENCY ACTION LEVELS p

1..

Page 31, Initiating Condition (IC) - Abnormal Reactor Coolant Temperature and/or Pressure or Abnormal Fuel Temperature That Would Indicate a loss of Subcooling Margin or Overpressurization, NOUE, Detection Method.

l The RCS pressure was changed from 2310 to 2735 psig based on NUREG-0654, Appendix 1, NOVE, Item 4, which addresses pressure / temperature condition -

outside of T. S. limits.

The 2735 psig value (Safety Limit) is not i

acceptable.

The licensee committed to change the value to equal the primary safety setpoint plus the high allowable tolerance which would -

equal approximately 2510 psig.

2.

Page 35,. IC - Failure of Offsite and Onsite Power Along With Total-Loss of Emergency Feedwater Makeup Capability, General Emergency, Initiating Condition The initiating condition reads for "several hours." The licensee views the phrase "several hours" as non-descriptive and committed to remove it from the initiating condition.

3.

Page 35, IC - Failure of Offsite and Onsite Power Along With Total Loss of Emergency Feedwater Makeup Capability, General Emergency, Detection Method For detection method 3, the licensee committed to remove the statement "for several hours" and replace it with "for greater than one hour."

The conditional "and" statement at the end of the sentence will be replaced with an "or" statement addressing detection method 4.

-4.

Page 35, IC.- Failure of Offsite and Onsite Power Along With Total Loss of Emergency Feedwater Makeup Capability, General Emergency, Detection Method A new detection method " Item 5. Containment pressure greater than 30 psig for at least 2 minutes" was added. Given the EAL conditions, waiting for the containment pressure to increase to 30 psig before declaring a General Emergency does not meet the anticipatory intent of NUREG-0654.

The-licensee committed to delete detection method 5.

5.

Page 40, IC - Security Threat Involving Imminent Loss of Physical Control of The Plant, Site Area Emergency, Detection Method The detection method as written requires imminent loss of the control room "and" auxiliary shutdown panels.

The sentence should read control room "and/or" auxiliary shut down panels.

The licensee has committed 4

d

l'l'

.,.s l

L f

to change the detection method to read "and/or".

6.

Page 40, IC - Security Threat Resulting in loss of Physical Control of The Plant, General Emergency, Detection Method The detection method as written requires loss of physical control of the L

control room "and" auxiliary shut down panels.

The sentence should read control room "and/or" auxiliary shut down panels.

The licensee has r

committed to change the detection method to read "and/or."

7.

Page 41 IC - Severe Natural Event Near Site, Item c. Sustained Hurricane Winds Greater Than 75 MPH, Alert, Detection Method The detection method was changed from " Meteorological monitoring system data or Weather Bureau re aort" to " Observation of the event."

The licensee connitted to rewr' te the detection method to read as written in the previous revision " Meteorological monitoring system dsta or Weather Bureau report."

8.

Page 41, IC - Severe Natural Phenomenon Being Experienced or Projected With Plant Not in Cold Shutdown, Item b. Sustained winds in excess of 100 MPH on site Site Area, Detection Method The detection method was changed from " Meteorological nionitoring system data or Weather Bureau report" to " Observation of the event". The change decreases the effectiveness of the Plan by deleting the specific indicators for this 10. The licensee committed to rewrite the detection method to read as written in the previous revision " Meteorological monitoring system data or Weather Bureau report".

9.

Page 45. IC - Loss of RHR Flow For More Than 20 Minutes during Half-Pipe Operation With Vessel Head Installed, NOVE, Initiating Condition The initiating condition meets the requirement for an Alert rather than a NOVE.

The initiating condition was not changed in the revision but, the initiating condition meets the requirement of NUREG-0654, Appendix 1, item 10 - for an Alert.

The EAL was written in response to Generic Letter 88-17 which discusses mid-loop operation.

The licensee has connitted to change the initiating condition from an NOVE to an Alert.

TABLE 5-1 STAFFING REQUIREMENTS FOR EMERGENCY CONDITIONS 1.

.The Electrical Maintenance requirement of 1 in 30 minutes and 1 in 60 minutes was changed to ? in 60 minutes. This change is not in agreement with NUREG-0654. The licensee committed to change the Electrical Maintenance augmentation requirements to comply with NUREG-0654.

2.

The augmentation requirement for 1 I&C Technician in 60 minutes was deleted. The licensee stated the change was a typo and would be corrected to comply with NUREG-0654.