May 17, 1990 Docket No. 50-395 j
Mr. O. S. Bradham Vice President, Nuclear Operations South Carolina Electric & Gas Company Virgil C. Summer Nuclear Station P. O. Box 88 Jenkinsville, South Carolina 29065
Dear Mr. Bradham:
SUBJECT:
APPLICATION TO INCINERATE CONTAMINATED OIL AT THE V. C. SUMMER NUCLEAR STATION, UNIT NO. 1 (TAC NO. 75877) i In your January 4, 1990 letter, you requested approval, in accordance with 10 CFR 20.302(a) and 10 CFR 20.305, to incinerate contaminated oil at the V, C.
Summer Nuclear Station, Unit No. 1.
We have reviewed your submittal and find that it is inconsistent with r,imilar submittals made for other plants.
In addition, discussions with your staff concerning your application revealed that your incineration plans are conceptual, rather than fixed. Therefore, because of these inconsistencies and because your plans appear too_ conceptual to support a review at this time, we are rejecting your application.
If you wish to pursue this application, then an amendment to your license is required.
Technical Specification (TS) changes are required.
They would typically include:
1.
A change to Table 4.11-2 to include radiation sampling and analysis of oil, e. g., each batch of oil to be incinerated would require a grab sample and analysis for principal gamma,9mitters with a lower limit of detection (LLD) of 5 X 10 microcuries per millimeter; 2.
Limitation on the dose rate to members of the public in TS 3.11.2.3 to 0.1 percent of the 10 CFR Part 50, Appendix I i
values; 3.
Change to Administrative Section 6.9.1.8 to include i
the radioactivity released as a result of incineration and the dry activated waste shipped as a solid radwaste in the Semiannual Radioactive Effluent Release Report; and 4.
Changes to the appropriate Bases of the TS.
In addition, your staff should review Regulatory Guide 1.143, " Design Guidance for Radioactive Waste Management Systems, Structures, and Components in
~ Light-Water-Cooled Nuclear Reactor Power Plants," to see if it is applicable.
It should be noted that the proposed acceptable dose level for your incineration e.ctivities is a f actor of 10 higher than that approved for other facilities.
S) 9005220157 900517 I
h PDR ADOCK 0500G395 V
P PDC
p.
e e
a c.
Mr. O. S. Bradham May 17, 1990 The above deficiencies and others associated with your submittal were discussed with your staff on April 19, 1990.
Sincerely, Original Signed By:
John J. Hayes, Jr., Project Manager Project Directorate 11 1 Division of Reactor Projects Office of Nuclear Reactor Regulation ec: See next page DISTRIBUTION See attached page i
.s n
- LA:1 Ibill
- PM' DII.1
- D:P I-l 1
..-.L......:..hy.
- EA e sam NAME : PAS h 7s
- JH
......:(................:.k//90
.......:7.---........:..............:..............:-----........
DATE : //6/90
. :/
94,'7,/90 OFFICIAL RECORD COPY Document Name: LTR BRADHAM 75877 i
l l
o 9
Mr. O. S. Bra dham I
South Carolina Electric & Gas Company Virgil C. Surrer Nuclear Station t
i cc:
Mr. R. V. Tanner i
Executive Vice President S.C. Public Service Authority P. O. Box 398)
Moncks Co rner, Sou th Ca ro lina 29461-0398 J. B. Knotts, Jr., Esq.
Bishop, Cook, Purcell and Reynolds 1400 L Street, N.W.
Washington, D. C.
20005-3502 Resident Inspector / Summer NPS c/o U.S. Nuclear Regulatory Commission Route 1, Box 64 Jenkinsv111e, South Ca rolina 29065 f
Regional Administrator, Region II U.S. Nucleer. Regulatory Commission, 101 Marietta_ Street, N.W., Suite 2900 l
. Atlanta, Georgia 30323 Chairran, Fairfield County Council P. O. Box 293 Winnsboro, South Carolina 29180 l
Mr. Heyward G. Shealy, Chief Bureau of Radiological Health South Carolina Department of Health and Environmental Control 2600 Bull Street Colunbia,. South Carolina 29201 South Carolira Electric & Gas Company Mr. A. R. Koon, Jr., Manager Nuclear Licensing Virgil C. Summer Nuclear Station P. O. Box 88 Jenkinsville, South Carolina 29065 b
t h
m DISTRIBUTION Dechet6FUe' 2 0 PDR Local PDR S. Yarga 14-E-4 G. Lainas 14-H-3 E. Adensam 14-B-20 P. Anderson 14-B-20 J. Ha 14-B-20 OGC(yesFor inform. On V)15-B-18 E. Jordan MNBB-3302 ACRS (10)
P-315 Sunsner File y
E i
1 l
P w