LCA 197 Attachment A Page 4 of 6 RE ACTIVITY CONTR,_Q1 SYST[MS
$NUTDOWN ROD INSERTION LIMIT LIMITING CONDITION FOR OPERATION cp /
Allshutdownrodsshallbefullywithdrawn(>2fsteps).
l /2 3.1.3.4 APPL 1CABit1TY: MODES 1* and 2*#
LGTjg:
T With a maximum of one shutdown rod not fully withdrawn, except for surveillance testing pursuant to Specification 4.1.3.1.2, within one hour either:
a.
Fully withdrew the rod, or b.
Declare the rod to be inoperable and apply Specification 3.1.3.1.
SURVEILtANCE RE001 REM [NTS 4.1.3.4 Each shttdown rod shall be deternined to be fully withdrawn:
a.
Within 15 minutes prior to withdrawal of any rods in control banks A B, C or D during an approach to reactor criticality, and b.
At least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> thereaf ter.
e s
'See Special Test Exceptions 3.10.2 and 3.10.4.
- With Keff > 1.0.
TROJAN-UNIT 1 3/4 1-22 Am_endmentNo.J2f TD_""__0.p t
l 9005100N0yj,[h44 PDR ADOCK ppc P
LCA 197 Attachment A l
Page 5 of 6 i
[
3 V
(2 (FgtY WITHDRAWN.:> 21$)A STEPS) l x
l l
i /ta.SS,224) l
/
l
/
too
/
(12.189)
/
/
/
/
/
SANK-C
/i ISO l
t
/
/
I E
/
l
/
I
/
/
e U
I O,118)
/
/
10 0
/ B_ANK-D E
~
/
I b
C
/
i
/
=
1
/
50 I
/
\\
l
/
/
/P o' ?)
l (FULLY 0
0.2 0,4 0.6 0,8 LO INSERTED)
FRACTION OF RATED THERMAL POWER FIGURE 3.1-1 ROD BANK INSERTION LIMITS VERSUS 'TERMAL POWER FOUR LOOP OPER ATION TROJAN-UNIT 1 3/4 1-24 Amendment No. #N, /// dI[
(M~iiik 20~19 a
g y
-.e,.s+-r
,.--.y m,
.---we-%
+
c LCA 197 j
Attachment A j
Page 6 of 6 j
s I
D 1
3
~_,
(FULLY WITHDRAWN,> 22% TEPS) l A Ss
/
22s f
f
/
/
200
/ BANK-C L
/I
/
(
f
/
/
150
/
5
/
e g
f eANx-o
/
a r-w
>=
M 10 0
/
x2 r
4 l
m 7
C g
O
)
E 30 f I
l l
( FULLY, 0
0.2 CA 04 0,8 -
INSERTED)
FRACTION OF R ATED THERMAL PCWER s
FIGURE 3.1-2 ROD BANK INSERTION LIMITS VERSUS THERMAL POWER THREE LOCP OPERATION TROJAN-UNIT 1 3/4 1-25 AmendmentJo.12$
liiarch 20,195D y
m y-.--
-=.-
m s.
-- m
j i
i-UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION in the Matter of
)
)
PORTLAND GENERAL ELECTRIC COMPANY,
)
Docket 50-344 THE CITY OF EUGENE, ORECON, AND
)
Operating License NPF-I PACIFIC POWER & LIGifT COMPANY
)
)
(TROJAN NUCLEAR PLANT)
)
)
i EERTIFICATE OF SERVICE I hereby certify that copies of License Change Application 197, to the j
Operating License for the Trojan Nuclear plant, dated May 7, 1990, have been served on the follewing by hand delivery or by deposit in the United States mail, first class, this 7th day of May 1990:
State of Oregon Department of Energy 625 Marion St NE Salem OR 97310 Mr. Michael J. Sykes Chairman of County Commissioners Columbia County Courthouse St. Helens OR 97051 h.
Scott A. Bauer, Manager Nuclear Regulation Branch Nuc1 car Safety & Regulation l
Subscribed and sworn to before me this 7th day of May 1990.
My Commission Expires:
Nothry Publ%4 V 0regon L
'N I
k L
.