i APPENDIX A NOTICE OF VIOLATION l

Nebraska Public Power District Docket: 50-298 Cooper Nuclear Station Operating License: DPR-46 During an NRC inspection conducted on March 26-30, 1990, a violation of NRC requirements was identified. The violation involved the failure of the inservice inspection (ISI) program to include Class 3 nonintegral component supports for examination for both the first and second 10-year !$1 intervals.

In accordance with the " General Statement of Policy and Procedure for NRC Enforcement Actions," 10 CFR Part 2, Appendix C (1989) (Enforcement Policy),

i the violation is listed below:

Failure to include ASME Class 3 Nonintegral Components Supports in the 151 Program Technical Specification 4.6.G for Cooper Nuclear Station states, in part, that inservice inspection of ASME Code Class 1, 2, and 3 components shall be performed in accordance with Section XI of the ASME Boiler and Pressure Vessel Code and applicable Addenda.

Paragraph IWD-2620, " Visual Examination VT-3" of Section XI of the ASME code states, in part, that the component supports and restraints within the boundary of each system specified in the examination categories of Table IWD-2500-1 shall be subject to the visual examination of VT-3 and shall be performed at the frequency specified in Table IWD-2500-1 (which is each inspection interval).

Contrary to the above, Class 3 nonintegral component supports from within the boundary of each system specified in Table IWD-2500-1, were not included in the first and second 10-year ISI program for VT-3 visual examinations.

This is a Severity Level IV violation.

(SupplementI)(298/9015-02)

Pursuant to the provisions of 10 CFR 2.201, Nebraska Public Power District is hereby required to submit to this office, within 30 days of the date of the letter transmitting this Notice, a written statement or explanation in reply, including for each violation:

(1) the reason for the violation if admitted, the corrective steps which have been taken and the results achieved, the corrective steps which will be taken to avoid further violations, and the date when full compliance will be achieved. Where good cause is shown, consideration will be given to extending the response time.

Dated at Arlington, Texas, this GML day of 1990 l