Advises That 900130 Request for Relief from ASME Boiler & Pressure Code Section XI Re Procuring Matls Denied.Submittal Fails to Demonstrate That Proposed Alternatives Would Provide Acceptable Level of Quality & Safety
ML20042E986
Person / Time
Site: Grand Gulf 
Issue date: 04/24/1990
From: Adensam E
Office of Nuclear Reactor Regulation
To: Cottle W
SYSTEM ENERGY RESOURCES, INC.
References
TAC-71945, NUDOCS 9005070065
Download: ML20042E986 (3)


Text

=.

t April 24, 1990

..Dockel. No.

50-416 Mr. W. T. Cottle Vice President, Nuclear Operatior*,

System Energy Resnurces, Inc.

P.O.. Box 756 Port Gibson, Mississippi 39150

Dear Mr. Cottle:

SUBJECT:

REQUEST FOR RELIEF FROM AMERICAN SOCIETY OF MECHANICAL ENGINEERS CODE REQUIREMENTS FOR PROCURING MATERIALS - GRAND GULF NUCLEAR STATION, UNIT 1 (TAC NO.

71945)

By !etter dated January 30, 1989, System Energy Resources Inc., (the licensee) requested relief from certain requirements in the American Society of r

Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (Code),Section XI, concerning the procurement of materials for use in repairing or replacing ASME,Section III, components or parts.

The Code requires that material manufacturers and suppliers either hold a Quality System Certificate (QSC) issued by the ASME or have their quality system programs surveyed and qualified by an N-type certificate holder.

Your letter requested relief from this requirement without specifying particular components for which the relief is presently needed.

The ASME is considering modification of the Code in this area.

The NRC staff has completed its review of your relief request (No. RR-00001).

The staff recognizes that there may be a need for relief in procuring materials for specific components; however, your request is for relief on all components covered by the Code.

Your submittal fails to demonstrate that for all components, compliance with the Code requirements would result in hardship or unusual difficulties, or that the proposed alternatives would provide an acceptable level of quality and safety.

These standards are required to be met by 10 CFR 50.55a(a)(3) for any proposed alternatives.

Accordingly, your relief request is denied, You are encouraged to explore other means of procurement allowed b/ the Code, such as obtaining an N-type certificate, t

Sincerely, Original Signed By:

Elinor G. Adensam, Director Project Directorate II-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation cc:

See next page

  • SEE PREVIOUS CONCURRENCES OFC :PD
P021 NPR
  • EMCB
  • RVIB
PD DRPR 7L....:............................................................

NAME :PA LKi tner:dt CCheng WBrach

RBachmann
EAd sam DATE :4/ g /90 4/f)/90
4/2/90
3/30/90
4/4/90
4/g /90 OFFICIAL RECORD COPY Document Nan,e:

LTR W.T. COTTLE o005070065 900424 h h i

V'@

.t PDR ADOCK 05000416 I

p PDC

a i

Mr'. W. T. Cottle System Energy Resources, Inc.

Grand Gulf Nuclear Station (GGNS)

CC; Mr. T. H. Cloninger Mr. C. R. Hutchinson Vice President, Nuclear Engineering GGNS General Manager

& Support System Energy Resources, Inc.

System Energy Resources, Inc.

P. O. Box 756 P. O. Box 31995 Port Gibson, Mississippi 39150-Jackson, Mississippi 39286-1995 Robert B. McGehen, Esquire The Honorable William J. Guste, Jr.

Wise, Carter, Child, and Attorney General Caraway Department of Justice P. O. Box 651 State of Louisiana Jackson, Mississippi 39205 P. O. Box 94005 Baton Rouge, LA 70804-9005 Nicholas S. Reynolds Esquire Bishop. Cook, Purcell Alton B. Cobb, M.D.

and Reynolds State Health Officer 1400 L Street, N.W. - 12th Floor State Board of Health Washington, D.C.

20005-3502 P. O. Box 1700 Jackson, Mississippi 39205 Mr. Jim T. LeGros Manager of Quality Assurance Entergy Services, Inc.

Office of the Governor P. O. Box 31995 State of Mississippi Jackson, Mississippi 39286-1995 Jackson, Mississippi 39201 Mr. Jack McMillan, Director President.

Division of Solid Waste Management Claiborne County Board of Supervisors Missitsippi Department of Natural Port Gibson, Mississippi 39150 Resources P. O. Box 10385 Jackson, Mississippi 39209 Regional Administrator, Region II U.S. Nuclear Reculatory Commission Mr. John G. Cesare 101 Marietta St., Suite 2900 Director, Nuclear Licensing Atlanta, Georgia 30323 System Energy Resources, Inc.

I P. O. Box 756 Port Gibson, Mississippi 39150 Mike Moore, Attorney General Frank Spencer, Asst. Attorney General Mr. C. B. Hogg, Project Manager State of Mississippi Bechtel Power Corporation Post Office Box 22947 P. O. Box 2166 Jackson, Mississippi 39225

. Houston, Texas 77252-2166 Mr. H. O. Christensen Senior Resident Inspector U.S. Nuclear Regulatory Commission Route 2, Box 399 Port Gibson, Mississippi 39150

77 If o..

[:.:

l

Subject:

Request for Relief - Grand Gulf Nuclear Station Unit 1 (Tac 71945).

L Doetteii(4Ga NRC PDR Local PDR S. Varga 14-E-4 G. Lainas 14-H-3 E. Adensam 14-B-20 P. Anderson 14-B-20 L. Kintner 14-B-20 D. Pickett 13-D-18 W. Brach R1

-R. Hermann 9-H-15 OGC(forinform.Only) 15-B-18 E. Jordan MNBB-3302 ACRS(10)

P-315 Grand Gulf Plant File e

5 P

h 5

i s

L'..