Submits Addl Info Re Containment Isolation Valve Operations During 1 Yr for Reasons Other than Testing.Number of Operations Represent Best Estimates Only
ML20042C052
Person / Time
Site: Big Rock Point File:Consumers Energy icon.png
Issue date: 03/26/1982
From: Vandewalle D
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Crutchfield D
Office of Nuclear Reactor Regulation
References
NUDOCS 8203300114
Download: ML20042C052 (3)


Text

,

CORSumBIS Power on.., v.

.n.

Nuclear Licenssng Administrator General offices: 1945 West Pamell Road, Jackson, MI 49201 + (517) 788-1636 March 26, 1982 N

/

p

'f[,,.y, v.

z\\

J Dennis M Crutchfield, Chief Q

fh Operating Reactors Branch No 5 q

(.

Nuclear Reactor Regulation a

V US Nuclear Regulatory Commission fk O Washington, DC 20555

'ru /7 l. - L',

I I t \\ ;

DOCKET 50-155 - LICENSE DPR BIG ROCK POINT PLANT - CONTAINMENT ISOLATION VALVE

SUMMARY

RESPONSE

Consumers Power Company was requested on March 23, 1982 to provide additional information supplementing our rebruary 12, 1982 letter on the operation and testing of containment isolation valves at the Big Rock Point Plant.

Specifi-cally, additional information was requested on the number of operations during a year for reasons other than testing. Estimates of the expected number of such operations for each containment isolation valve are provided in the attachment.

It must be emphasized that the numbers shown under the column labeled " Estimate of Operations Other Than Testing," are only our best estimate of the number of operations. Substantiation of these numbers would require a thorough and time consuming search of plant records, and might not even be possible.

In addition, for those penetrations in which a check valves serves as the isolation valve (and also for the valves associated with the locks) it is very difficult to estimate the number of challenges per year, and thus for those valves the asterisk (*) indicates that the number of operations is unknown.

T

?

I lDavidJ'VandeWalle ll[L J

tL l

POD Nuclear Licensing Administrator J

CC Administrator, Region III, USNRC

//

NRC Resident Inspector-Big Rock Point pages oc0382-0036a142 8203300114 820326 PDR ADOCK 05000155 P

PDR

,/

Big Rock Point 1

Containment Isolation Valve Summary Response TABLE I CONTAINMENT ISOT.ATION VALVES, PENETRATIONS AND LOCKS Tests Leak tstimate of Stroke Rate operations Item Number Item Description Tests Tests Failure other Than Testing CV 4094 Ventilation Exhaust Valve 20 2

1 __

120 CV 4095 Ventilation Exhaust Valve 20 2

1 __

120 CV 4096 Ventilation Supply Valve 20 2

120

~

CV-4097 Ventilation Supply Valve 20 2

120 SV-9155 Ventilation Probe 8

0 132 SV-9156 Ventilation Probe _

8 0

132 Personnel Lock 2

90,000 Personnel Lock Powell Check Valve 2

Personnel Lock Jenkins Valve 0

Equipment Lock 2

75 Equipment Lock Powell Check Valve 2

Equipment Lock Jenkins Valve 0

2' Escape Lock 400 Nordstrom Equalizing Valve 0

H-40 Conax Penetration 2

H-65 Conax Penetration 2

H-81 Conax Penetration 2

H-83 Conax Penetration 2

,CV-4025 Dirty Sump Pump Discharge 8

0 2

CV-4103 Dirty Sump Pump Discharge 8

0 2

VEC-301 Emergency Condenser Drain Check 0

0

  • Not applicable nu0282-0012c142

Big R5ck Paint 2

Containment Isolation Valve Summary Response Tests Leak Estimate of Stroke Rate Operations Item Number Item Description Tests Tests Failures Other Than Testing CV-4031 Clean Sump Pump Jischarge 8

0 2

CV-4107 Clean Sump Pump Discharge 8

0 2

Emergency Condenser Shell Side Sample Point Check Valve 1

VEC-107 EC Sight Glass Vent Valve 1

CV-4049 Treated Waste Return

~

0 0

24 VRW-313 Treated Waste Return Check Valve O

24 CV-4105 Demin Water Isolation Valve 7

0 0

Check Valve Demin Water Isolation Check Valve O

O CV-4091 Resin Sluice Valve 1

0 2

CV-4092 Resin Sluice Valve 1

0 2

CV-4093 Resin Sluice Valve 1

0 2

CV-4027 Reactor and Fuel Pit Drain 1

2 2_

10 CV-4117 Reactor and Fuel Pit Drain 1

1 1 __

10 VRD-310 CRD Supply Check Valve 1

o VRD-311 CRD Supply Check Valve 1

0 HO-7050 Main Steam Isolation Valve 0

1 2

MO-7065 Main Steam Drain Valve 0

1 0

VW-304 Feedwater Check Valve 1

H-80 Penetration 0

H-88 Penetration 0

H-91 Penetration 0

l i

)

  • Not applicable nu0282-0012c142