Text
,
.
.
ynnotiq'o
UNITED STATES
~g
8 '^
NUCLEAR REGULATORY COMMISSION
o
$3
E
REGION 11
101 MARIETTA ST., N.W., SulTE 3100
o,
-
%
ATLANTA, GEORGIA 30303
s
4. . e
'
Report No. 50-369/82-04
Licensee:
Duke Power Company
P. O. Box 2178
Charlotte, NC 28242
Facility Name: McGuire Nuclear Station
Docket No. 50-369
License No. NFP-9
Inspection at McG f re si.te,near Corneli
NC
uffg29gg
4?
.7
3
Inspector:_
,,
4. L. Cun in
m'
tate digned
g
Approved by:
d._
_
3 ([_ [1
D. M/Mofit omeFy, Section Chief, IM&EP Section
t6
igned
POS(Division
SUMMARY
Inspection on February 16-19, 1982
Areas Inspected
This routine, unannounced inspection. involved-27 inspector-hours on site in the
area of radiological environmental monitoring including management controls;
implementation of the environmental monitoring program;- review of licensee
interlaboratory comparison program; assessment of licensee's response to NRC
Bulletin 81-03; review of licensee's program for quality control of analytical
measurements.
Results
e
Of the five areas inspected, no violations or deviations were identified.
!
!
8203250471 820304
QDRADOCK 05000369
l
- - - .
_.
.
. . _
.
. ,._
.
_
_
l
.
,
,
o
REPORT DETAILS
1.
Persons Contacted
Licensee Employees
- M. D. McIntosh, Station Manager
- H. B. Tucker, Manager, Nuclear Production Division
- J. W. Foster, Health Physics Coordinator
- D. H. Franks, Quality Assurance Supervisor
- W. M. Sample, Projects and Licensing Engineer
- D. D. Lampke, Licensing Engineer
T. J. Keane, Station Health Physicist
J. Isaacson, Radiochemist
- Attended exit interview
2.
Exit Interview
The inspection scope and findings were summarized on February 19, 1982, with
those persons indicated in paragraph 1 above.
3.
Licensee Action on Previous Inspection Findings
No previous inspecthn findings remained outstanding.
4.
Unresolved Items
Unresolved items were not identified during this inspection.
5.
Management Controls
a.
Management and administrative controls defined in Section 6 of the
Technical Specifications for Unit 1, were reviewed by the inspector
with respect to the following items:
(1) organizational and management
responsibility for implementation of the radiological environmental
monitoring program required by Technical Specification 3/4.12; (2)
periodic audit of the environmental monitoring program; (3) radio-
logical environmental procedures. These items are discussed below,
b.
Technical Specifications 6.1 and 6.2 assign management and organiza-
tional responsibility for implementation of the offsite radiological
monitoring program. The inspector conducted a comprehensive review,
including discussions with cognizant licensee representatives, of
specific management responsibility for assuring implementation of the
-
.
.
,
2
monitoring program.
Management of the offsite radiological environ-
mental monitoring program is the direct responsibility of the Station
>
Health Physicist. Sample collection and environmental surveillance is
implemented by an assistant health physics technician under the
direction of an assigned health physics supervisor.
Management
responsibility for. radiochemical analysis of environmental samples is
an offsite function assigned to the Technical and Environmental Service
Group.
The System Health Physicist is assigned management responsi-
bility for radiochemical analysis of samples listed in Table 3.12-1 of
Technical Specification 3/4.12.1.
Analyses are implemented by the
Environmental Radiological Laboratory staff under the direction of the
Laboratory Services Supervisor.
Inspection disclosed that organiza-
tional responsibility for and management of the radiological environ-
mental monitoring program 'were consistent with requirements of the
above cited specifications.
c.
Technical Specification 6.5.2.9.k requires that a periodic audit of the
environmental monitoring program shall be conducted, at least, once per
12 months.
The inspector reviewed the section of licensee Audit
Report No. SP-81-9(MC) dated September 29, 1981, which addressed the
sampling and surveillance requirements of the radiological environ-
mental monitoring program defined in Table 3.12-1 of Technical
Specifica* ion 3/4.12-1. The audit disclosed no findings regarding the
referenced program. The inspector had no questions.
d.
Technical Specification 6.2.5.9.n requires., at least, once per 12
months, an audit of the performance of ae.ivities required by the
quality assurance program to meet the criteria of Regulatory Guide 4.15
(December 1977).
The inspector reviewed licensee Audit Report No.
SP-81-10(GO) dated November 3,1981.
The audit was conducted during
the period September 21, 1981 through October 7,
1981.
Inspection
included the following:
(1) discussion with _ a cognizant _ licensee
representative of the audit and it's . respective findings and recom-
mendations;. (2) review of licensee or'ganization's re'sponse to _ such -
findings; (3) verification of adequacy of corrective actions imple-
mented. Inspection disclosed that required followup and completion of
corrective actions in response to audit findings were implemented with
the exception of those findings which addressed procedures, viz.: (1)
SP-81-10(GO)9 and SP-81-10(GO)10 regarding approval and review,
respectively,
of environmental
radiological
laboratory control
procedures; (2) SP-81-10(G0)11 addressing failure of referenced
procedures to use the terms "shall", or its equivalent, to indicate
mandatory compliance, where such compliance is required.
Inspection
disclosed that the subject procedures were revised as required and were
submitted for review and approval .
The inspector informed licensee
representatives
that
the
environmental
radiological
laboratory
procedures would be reviewed during a subsequent inspection te verify
that review and approval were implemented as required (Su-369/
82-04-01).
.
.
.
3
e.
Technical Specification 6.8.1.1 requires that written procedures which
address the quality assurance program for effluent and environmental
monitoring using guidance in Regulatory Guide 4.15 (December 1977)
shall be established, implemented and maintained.
Inspection
included a detailed review of radiological environmental sampling and
surveillance procedures complied under Procedure PT/0/B/4600/26 (Rev.
O, 9/22/80) which addresses all sampling and surveillance requirements
listed in Table 3.12-1 of Technical Specification 3/4.12.1. Inspection
disclosed that the procedures were reviewed and approved as required.
Inspection also disclosed, however, that the subject procedure required
the following changes:
(1) update to reference Technical Specification
3/4.12 and applicable tables therein; (2) required submission of
environmental samples to environmental radiological laboratory for
radiochemical analysis following scheduled sample collection. The
above procedures will be reviewed during a subsequent inspection
(50-369/82-04-02).
f.
Inspection also included a detailed review of the environmental
radiological laboratory control procedures. These procedures and the
findings related thereto are discussed ;n paragraph 5d, above. The
scope and contents of monitoring and laboratory control procedures were
consistent with guidance regarding operating procedures and quality
catrol defined in Sections C.3 (0perating Procedure and Instructions),
C.S (Ouality Control in Sanpling (Including Packaging, Shipping, and
Storage of Samples), and C.6 (Quality Control in the Radioanalytical
Laboratory (including calibration reference standards, performance
checks of radiation measurement systems, analysis of QC samples,
inter-and-intralaboratory analyses, computational checks, review and
analysis of data)) of Regulatory Guide 4.15 (December,1977). The
series of environmental radiological laboratory procedures reviewed are
listed below.
(1)
1000 Series - General Administrative Procedures
(2) 2000 Series --Environmental Radiological Laboratory Procedures
(3)
3000 Series - Ouality Control Procedures
(4)
4000 Series - Radiological Instrumentation Procedures
(5) 5000 Series - Non-Radiological Instrumentation
(6) 6000 Series - Radioactive fiaterial Control Procedures
(7)
7000 Series - flaintenance Procedures
.
b
.
.
.
4
6.
Analytical Quality Control *
Inspection included a detailed review of the licensee's quality control
procedures, related administrative procedures, and analytical quality
control program data compiled during the period January 1 - December 31,
1981. The procedures reviewed included Procedure Nos. 3000/01(Daily
Instrument Linearity, Source and Background Check), 3000/02 (Radioactive
Standard Preparation), 3000/03 (Analysis of EPA Cross-Check Samples),
1000/04 (Administration ,of Interstation Cross-Check Program). The 2000 and
and 4000 Series Procedures, listed in the preceeding paragraph, were also
reviewed. Available EPA Cross-Check Program data, compiled during calendar
year 1981 was reviewed and discussed with a cognizant licensee representa-
tive.
Inspection disclosed that the analytical quality control program was
~
consistent with the guidance defined in Section C.6 of Regulatory Guide 4.15
(December 1977).
Inspection further disclosed close and consistent
agreement of licensee cross-check analytical results with those of EPA in
the assigned cross-check program. The inspector had no questions regarding
this item,
7.
Status Review of Radiological Environmental Monitoring Program
a.
Technical Specification 3/4.12 defines all requirements for the
radiological environmental monitoring program which includes the
following:
(1) specific sampling / analytical 1 parameters and. schedule _s; _
(2) reporting levels for specific radionuclide concentrations in the
environment associated with plant operation; (3) maximum values of
lower limits of detection (LLD's) for required . analytical parameters;-
(4) land use census; (5) interlaboratory comparison program discussed
in paragraph 6, above.
b.
Inspection included a review of program organization and management
control to assure that all program requirements were implemented as
required by the technical specifications.
Inspection also included the
following:
(1) a review of sampling records and data compiled during
the 1981 calendar year; (2) inspection of all air particulate
monitoring stations and verification of required quarterly calibration
of the nonitors inspected; (3) inspection of all surface and service
water monitoring stations; (4) inspection of ten randomly selected TLD
stations (excluding those TLD's located at air particulate /radiofodine
monitoring stations); (5) review of land census data for calendar year
1981, (6) inspection of milk sampling stations.
c.
Inspection disclosed that the radiological environmental monitoring
program was adequately managed to assure implementation of the
technical specification requirements.
Inspection further disclosed
'
that environmental sanpling and radiochemical analysis of samples
collected were consistent with all requirements defined in Section
3/4.12 of the Technical Specifications. There were no questions
regarding this item,
www
r
--
s-
4m.
'
.
..
.
5
8.
The inspector reviewed the licensee's response to IE Bulletin 81-03 (Flow
Blockage of Cooling Water to Safety System Components by Corbicula Sp.
(Asiatic Clam) and Mytilus Sp. (Mussel)). Although no fouling has occurred
as a consequence of clam infestation, the licensee discovered Corbicula Sp.
(Clams) during preoperational testing of the Fire Protection Sy sten' in
August of 1978.
The licensee has implemented periodic monitoring of the
Nuclear Service Water System and performance tests are conducted monthly to
insure adequate flow to the Nuclear Service Water Pumps.
In view of the
absence of clans in the subiect system, no control measures have been
implemented to date. In the case of the Fire Protection System, chlorine is
periodically added to the system to maintain a chlorine residual lethal to
young (non shelled) clams. There were no questions regarding this item.