Monthly Operating Rept for Dec 1981
ML20042B498
Person / Time
Site: Big Rock Point File:Consumers Energy icon.png
Issue date: 01/04/1982
From: Amstutz S
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
Shared Package
ML20042B492 List:
References
NUDOCS 8203250368
Download: ML20042B498 (5)


Text

- - _ _.

~~~

~~~

~

i$

7-e:

)

r;q n-U-

8203259 gDRADDhgOf0ho155 07 PDR GREYD0'OK OPERATING DATA REPORT

.D0CKFT NO._50-155.

D A I E L _.._1 _./

4_L02____

BY:

SUSAN AMSTUTZ PHONE:

616-547-6537, EXT *

,M.RAITNG STATUS stil N AliE :

DIG ROCK POINT NUCLEAR PLANT _.

__NOT m 1An_._

?

EP0ic T ING PERIOD:

12 / 01 il C i'. N E D THERilAL POWER (liuT )

240 ij,,

3 -p nhE" LATE RATIllG (GROSS tiUE).

75

'~

'N E

' fi!.ECTP tCAL RATING (NET tiUE)'

72

' c lij l'EPENDADLE CAPACITY (GROSS MWE) 69.0 m' ' t i4ii DEPENDADLE CAPACITY (NET MWE)

^5 0

F CllANGES DCCUR IN CAPACITY RATINGS (ITEMS;3rTHRU 7) SINCE[,l. ASTyREPORTl[-; GIVE : REASONS :

) idik 3P U N d ',

I

.r l

1)MER LEVEL TO WHICH RESTRICTED,IF ANY.INET fiWE) -

_65.0 d% F ', Q ; # ' <.i f.w?? g-2d 'i'lp&., m#

EASONS FOR RESTRICTIONS, IF ANY:

' g'

~

~-.

Ql]..Q~

g z,w

+

> :, - x I

T H.I.S N 0 tit H YEAR -T0.Df2Tr cutitiL1JX.

.bb?f ; x b18760.0J

.164467.0'

,. t Ai4 3

'q,

a:

OURS IN REPORTING PERIOD d '[

744IO

}

c

'8Q02 i i_15.1.02.5__ d

'e*

_ 7.41 0 W D OliDER OF HOURS REACTOR WAS CRITICAL _.._.

0.0 0.0 0.0 l

EAf' LOR RESERVE SHUTDOWN HOURS OURS GENERATOR ON-LINE 744.0 7940.0 112870.0

...O.0 0.0 0. Q_.)

"1( RESERVE SHUTDOWN.HOUKS ghy4$7',134059.0j ?g y g $.{624704.05

. C,f g*21145905.0 RUSS TilERilAL ENERGY GENERATED (MWH) yb 8Nty W498221!.0',

-6663310.0

  • 'Wx-41798.0-2 It M.___3.9166.9'O +;k ROSS ELECTRICAL ENERGY GEllERATED (MWH) 46195_4 _1___

c.6303.7AA,0__;

ET ELECTRICAL ENERGY GENERATED (MWH)__._

UII.?ERVICE FACTOR 100.0%

90.6%

68.6%'

&lI I AVAILADILITY FACTOR 100.0%

90.6%

68.6%'

Of I T CAPACITY FACTOR (USING liDC NET) 81.0%

82.6%

56.0%'

Di t i CAPACITY FACTOR (USING DER NET) 73.1%

74.5%

53.2%,

all i FORCED OU'IAGE RATE 0.0%

0.7%

19.3%i Ulli tDOHilS SCllEDULED OVER NEXT.6 tiONTHS(TYPE, DATE, & DURATION OF EACH):

A*

, e.

-/ f i

o,.

t

=,

.Tyv; 3.../

.s-3 4

5 e

i Il.

9,

~

a e8

.x 10 II 13 1(

1

.c igj

.n.~.;r-~

.~w.

.~. O __ :L

..s v 13

. a..

t u n.

_,.a c.

l6

.y

..a.

. -f.

._.;_~,_.

.."r..-

f. g..

r m

=e.s.

r.__v. m w w

w _

- b.a &.,.. > ;,

n

, w.

.,; m.

...:. v.

. a. :. m 4 u,c, ;.

2,=. n d' O u,.';. ;,,: '. ;.,* L.a.,;, na.; ;.

,.5&m,,r..+.. e.v m.,

_~r, =. w _;m_.qv...n.u w w.~r.: /u.

.xn,.::..:.

,;.se:...

~-r 2

.~. o:.,, _e, n

te.. _.., -n :.:

. ~.t -.~

c -

~,..a -

_m..

...m._..

m.

.-.m

..m c

  • A,.[.,3tM M"&

. );22 ;l _ "*'

c.,,._

'n.;., h -

.T

^

n 23 n

. a "l

DAY AVERAGE DAILY POWER (MWT)

(MWEN)

(12/81)

O i_

_192 A2 sA.29 8'

2 193.29 56.27 3

189.83 55.80 88 4

190.04 59 AO U

4.5,.

189.46 a

55'.44 h.

- ;.. fr.w.

-..05.'4.'.G. ~. _. <

S_ E.. '

' C_... ~' E. M......J_

55.08

3rl

d.. ;6Y.. -

188.21

. ga ; 7mw

_ e:.u:: b.;re:..

n

. _. 7.:.

$p7.,o 8

187.04 54.46 9

186.75 54.20 10 i B_4. 75_

___.5L ? A R

11 183.92 53.72 F

12 183.29 53.49 l

1 3...

_ i83.2.9_

_ _.53.3.0 14 182.17 53.00 15 181.00 52.70

.1 o..

1 sq 0..s O. __...__._.5,.So___...__..._..

17 179.46 52.24 18 178.50 52.11 19.

i78.08._

_ _ _.. _.__.51.82 20 176.96 51.67 l'

21 176.50 51.35 l"_

2 2..___ _ _.. _.. _

17.5. 0 4.._

_.51.20 23 174.12 50.95 ns

< -( n. =a u ce.U, n

JU l

u m

'e

-.a 1'.o.91 50.66.._.___

l 26 171.79 50.38 27 170.67 50.15

~

28

.._._.__170.33.

49.83___..

27 169.17 49.63 l

20 168.54 49.37 31 168.12 49.14_

UNIT SIIUTDOWNS AND POWER REDUCTIONj DOCKET NO. 50-155 i*

l UNIT NAME Bie Rock Point DATE 01-07-N December, 1981 COMPT.ETED BY SRAmstutz REPORT MONTil

. TELEPilONE 616-547-6537 ext 180 e.

.! ?

)

.Y Licensee Ee, vl, Cause & CorrectIvc o"

Action tu No.

Date g

gg g

jg5 Event

,g?

j3 H

$E jdig Repori

  • m0 Prevent Recurrence b

(

None

)

l l

\\

l I

2 3

4 F: Forced Reason:

Method:

Exhibit G. instructions S: Scheduled A. Equipment Failure (Explain) 1 Manual for Preparation of Data I,l X Maintenance of Test 2-Manual Scram.

Entry Sheets for Licensee C Refueling J Automatic Scram.

Event ReporI (1.ER) File (NUREG.

I D Regulatory Restriction 4-Other (Explain) 0161)

,l E-Operator Training & Ucense Examination F-Administrative 5

G-Operational Error (Explain)

Exhibit I.Same Sourec (9/77)

Il Other (Explain)

,l

, 7.. ; _.

,s UNIT SHUTDOWNS AND POWER REDUCTIONS clNSTRUCTIONS This report should describe all plant shutdowns during the in accordance with the table appearing on the report form report period. In addition,it should be the source of explan.

If category 4 must be used, supply brief comments.

^

ation of significant dips in average power levels. Each signi-LICENSEE EVENT REPORT #.

Reference the applicable ficant reduction in power level (greater than 20% reduction in average daily power = level for the preceding 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />) reportable occurrence pertaining to the outage or power should be noted, even though the unit may not have been reduction. Enter the first four parts (event year, seauential shut down completely. For such reductions in power level, report number, occurrence code and report type) of the five l

the duration should be listed as zero, the method of reduction Part designation as described in Item 17 of Instructions for should be listed as 4 (Other), and the Cause and Corrective Preparation of Data Entry Sheets for Licensee Event Report Action to Prevent Recurrence column should explain. The (LER) File (NUREG-0161). This information may not be Cause and Corrective Action to Prevent Recurrence column immediately evident for all such shutdowns,of course,since should be used to provide any needed explanation to fully further investigation may be required to ascertain whether or describe the circumstances of the outage or power reduction.

not a reportable occurrence was involved.) If the outage or power reduction will not result in a reportable occurrence.

NUMBER. This column should indicate the sequential num-the positive Indication of this lack of correlation should be bet assigned to each shutdown or significant reduction in power noted as not applicable (N/A).

for that calendar year. When a shutdown or significant power SYSTEM CODE The system in which the outage,or power reduction begins in one report period and ends in another, reduction originated should be noted by the two digit code of an entry should be made for both report periods to be sure Exhibit G - Instructions for Preparation of Data Entry Sheets all shutdowns or significant power reductions are reported.

for Licensee Event Report RER) File (NUREG.0161).

Until a unit has achieved its first power generation, no num-ber should be assigned to each entry.

Systems that do not fit any existing code should be designa.

ted XX. The code ZZ should be' used for those events where DATE. This column should indicate the date of the start a system is,not applicable.

of each shutdown or s! nificant power reduction. Report E

as year, month, and day. August 14,1977 would be reported COMPONENT CODE. Select the most appropriate component as 770814. When a shutdown or sigrdficant power reduction from Exhibit I Instructions for Preparatiorrof Data Entry beginsin one report period.ind ends in another, an entry should Sheets for Licensee Event Report (LER) File (NUREG.0161) -

be made for both repo:t periot!s to be sure all shutdowns using the following critieria:

or significant power reductions are reported.

TYPE. Use "F" or "S" to indicate either " Forced" or " Sche-duled." respectively, for each shutdown or significant power B.

If not a component failure, use the related component:

fI orced shutdowns include those required,to be e.g., wrong valve operated through error, list valve as reduction.

initiated by no later th n the weekend fo!!owing discovery component.

of an off-normal condition. It is recognized that some judg-i ment is required in categorizing shutdowns in this way. In C.

If a chain of failures occurs, the first component to mal-general, a forced shutdown is one that would not have been function should be listed. The sequence of events,includ.

completed in the absence of the condition for which corrective ing the other components which fail, should be described action was taken.

under the Cause and Corrective Action to Prevent Recur.

l rence column.

DURATION. Self. explanatory. When a shutdown extends Components that do not fit any existing code should be de.

beyond the end of a report period, count only the time to the signated XXXXXX. The code ZZZZZZ should be used for end of the report period and pick up the ensuing down time events where a component designation is not applicable.

in the following report penods. Report duration of outages rounded to the nearest tenth of an hour to facilitate summation.

CAUSE & CORRECTIVE ACTION TO PREVENT RECUR.

The sum of the total outage hours plus the hours the genera-RENCE.' Use the column in a narrative fashion to amplifyor tot was on line should equal the gross hours m the reporting.

explain the circumstances of the shutdown or power reduction.

Period.

The column should include the specific cause for each shut.

down or significant power reduction and the immediate and REASON. CateForize by letter designatmn in accordance contemplated long term correctise action taken, if appropri-with the table appearing on the report form. If category H ste. This column should also be used for a description of the must be used. supply brief comments.

- major safety.related corrective maintenance performed during the outage or power reduction including an identification of METl!OD OF SHUTTING DOWN THE REACTOR OR the eritical path actidty and a report of any single release or REDUCING POWER.

Catesorize by number designation radioactivity or sm;!e radiation exposure speettieally associ.

/

INote that this differs from the Edison Electrie Institute sted with the outage which accounts for more than 10 pereen.

(EEI) definitions of " Forced Partial Ont. ice" and " Sche, oi the allowable annual values.

\\

duled P;ntial Outag." For these term >. LI.1 uses.i change of For long textual reports continue narrative on separate paper 30 MW as ti e bre.ii pomt Foi larges powei re.tetors.30 MW and reference the shutdown or power reduetun for thr>

1

\\

o sw Refueling Information Recuest 1.

Facility name:

Big Rock Point Plant 2.

Scheduled date for next refueling shutdown:

February, 1982 3

Scheduled date'for restart following shutdown:

April, 1982 4.

Will refueling or resumption of operation thereafter require a technical specification change or other license amendment?

yes If yes, explain.

The two Technical Specification changes:

(1) Nuclear Steam Supply System - Heatup, Cooldown, Hydrotest and Criticality Curves (2) Reload H MAPLHGR limits change 2

If no, has the reload fuel design and core configuration been reviewed by Plant Safety Review Committee to determine whether any unreviewed safety questions are associated with the core reload (Ref.10CFR,Sec.50 59)?

No - the final physics package vill not be.

If no review has taken place, when is it schIeduled?

1 take place during the outage once the final physics Thereviewvi}6mittedtothePlant.

package is su' 5

Scheduled date(s) for submittal of proposed licensing action and supporting information:

None 6.

Important licensing censiderations associated with refueling, e.g., new or different fuel design or supplier, unreviewed design or performance ana-lysis methods, sigaificant changes in fuel design, new operating procedures:

Yes - revision of only MAPLHGR limits fcr reload H

  • 2 l

7 Nudber of fuel assedblies in: core 8h

spent fuel storage pool 108 8.

Present licensed spent fuel storage capacity:

193 l

Size of any increase in licensed storage capacity that has been requested or is planned (in nudber of fuel assemblies):

2h8 9

Projected due date of the last refueling that can be discharged to spent fuel l

pool assuning the present licensed capacity:

l 1983

.