Responds to 811229 & 820212 Requests for Info Re TMI Action Plan Items II.F.1.1,II.F.1.2 & II.F.1.3.New High Range Noble Gas Effluent Monitors Installed for Stack,Turbine Bldg Vent & Radwaste Bldg Vent
ML20042B467
Person / Time
Site: FitzPatrick 
Issue date: 03/19/1982
From: Bayne J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: Vassallo D
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.F.1, TASK-TM JPN-82-30, NUDOCS 8203250341
Download: ML20042B467 (2)


Text

_______ ___ _

=

a POWER AUTHORITY OF THE STATE OF NEW YORK 10 COLUMBUS CIRCLE NEW YORK, N. Y.10019 q2121 397 6200 G 8 0 ",G E,T,gs t,n n ycwsr rausfras JOHN BOSTON JOwn s ovsON C De al A M A N peg gspg NT--f ROC E DURE.

cronor c.iuontos JOSEPH sC IEDER vice cnateman

'"'a*/,a" *"'"

.ics.no a rtvus g

ROBE RT i. MILLONIl LEROY W. stNCLAin March 19, 1982

~ica vic e anie=

JPN-82-30 o r r"El=""

ranosaica n. cuanz Director of Nuclear Reactor Regulation Twouas R FREY U. S. Nuclear Regulatory Commission

!".",' *,".',',"c l"/,* 1' "'

Washington, D. C.

20055 Attention:

Mr. Domenic B. Vassallo Operating Reactors Branch No. 2 to Division of Licensing M

f

Subject:

James A. FitzPatrick Nuclear Power Plant E

pg. g ; y Docket No. 50-333 u.,b]e Gas Effluent Monitors 5

MAR 2 51982* [e PostacC lent Effluent Sampling for Iodine Nprm N and Particulates fE3Di sauDEN il p

Containment High-range Radiation Monitors N

M NUREG-0737 Items II.F.1.1.,

II.F.1.2 and II.F.1.3

References:

1.

NRC letter, T. A. Ippolito to G. T. Berry, dated December 29, 1981 2.

NRC letter, D. B. Vassallo to G. T. Berry, dated February 12, 1982 3.

PASNY letter, J. P. Iiayne to T. A. Ippolito, Dated July 7,1981 (JPN-81-49)

Dear Sire References 1 and 2 requested that the Power Authority identify any technical exceptions being taken to the requirements of the subject NUREG-0737 items. These letters also requested that the NRC staff be promptly notified of any difficulties encountered in meeting the implementation dates.

si response to Item II.F.1.1, the Power Authority installed new high range noble gas effluent monitors for the stack, turbine building vent and radwaste building vent. When complete, these modifications will meet all of the NUREG acceptence criteria, including the requirement for an unspecified amount of range overlap between the new and existing monitors.

Completion of these modifications was scheduled for the Reload 4/ Cycle 5 refueling outage which is now over. Two new high range stack monitors were installed and one is operational. The new high range monitors for the turbine and radwaste building vents are installed and operable, but do not have the expected low range sensitivity. Therefore, the new and existing monitors do not overlap. The new monitors are being modified to overlap the existing units. The Power Authority will notify the NRC when this work is complete and the new monitors are in service.

8203250341 820319 i

PDR ADOCK 050u3333 e

P PDR 71 h

i

e

  • During a recent exit interview with the Region I staff at the FitzPatrick plant, the Power Authority committed to meet the acceptance criteria for Postaccident Accident Effluent Sampling for Iodine and Particulates, NUREG-0737 Item II.F.1.2.

However, due to the technical complexity of the equipment required to meet the criteria and the magnitude of the modification, the Power Authority will not have this modification completed until the 1984 Reload 6/ Cycle 7 refueling outage. The Power Authority considers the existing sampling capability, which complies with NUREG-0578, to be adequate until the new system is operational.

NUREG-0737 Item II.F.1.3 requires containment high range radiation monitors.

Item II.E.4.2. (7) requires closure of the containment vent and purge isolation valves on high radiation in containment. The Power Authority elected to satisfy both of these NUREG-0737 items with a single modification as described in Reference 3.

Two new monitors, which are now fully installed, meet the acceptance criteria of both of the NUREG items. One of the two monitors is fully operational and will isolate the vent and purge lines on high radiation in containment. Therefore, Item II.F.4.2.(7) is fully implemented. The second installed monitor, however, is generating spurious containment isolation signals and has been removed from service. The NRC will be notified when this monitor is put back into operation and Item II.F.1.3 is fully implemented.

If you have any further questions, please do not hesitate to contact us.

Very truly yours, P.

Bayne 7

Se

.r Vice President Nuclear Generation cc: