Application to Amend License NPF-5 to Implement Encl GE Rept Y1003J01/A32, Supplemental Reload Licensing Submittal for Hatch Nuclear Power Station Unit 2 Reload 2
ML20042A873
Person / Time
Site: Hatch 
Issue date: 03/11/1982
From: Beckham J
GEORGIA POWER CO.
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20042A874 List:
References
TAC-48110, NUDOCS 8203240224
Download: ML20042A873 (2)


Text

_ _ _ _

0 n

4

+.-2 Georgia Power N' DN J. t ecc5n m. ar.

r R

Director of Nuclear Reactor Regulation

[

t U. S. Nuclear Regulatory Commission (s

<o#

Washington, D. C.

20555 4

2 pfS 2 31982# ~.

9-

% p a,ruc m,

a r =a u

'f NRC DOCKET 50-366 G

OPERATING LICENSE NPF-5 EDWIN I. HATCH NUCLEAR PLANT UNIT j

RELOAD 2 TECHNICAL SPECIFICATIONS A

g\\

Gentlemen:

In accordance with the provisions of 10 CFR 50.90, as required by 10 CFR 50.59(c)(1), Georgia Power Company (GPC) hereby proposes an amendment to the Unit 2 Technical Specifications (Appendix A to the Operating License).

The proposed anendment would incorporate revised specifications for cycle 3 operation with the Reload 2 fuel inserted.

The enclosed topical report prepared by General Electric Company (GE) for GPC, Y1003J01A32, December v' 1981, " Supplemental Reload Licensing Submittal For Hatch Nuclear Power Station Unit 2 Reload 2," presents the results of plant unique analyses performed for Reload 2.

Also enclosed, as attachment II of this letter, are the proposed changes to the Technical Specifications to implement the v results of the GE analyses.

The proposed changes to the Technical Specifications provide cycle 3 specific Operating Limit APLHGR and MCPR values.

The APLHGR values for the P8DRB283 type fuel are published in the referenced topical report as generated by the standard GE loss-of-coolant accident analysis methodology, and demonstrated conformance with 10 CFR 50 Appendix K.

Non-pressurization transient MCPR values were calculated using the REDY code.

The MCPR values for pressurization events were ' calculated using the ODYN code.

Using NRC approved methodology, the Operating Limit MCPR values were established for both Option A and Option B scram times.

The deteImination of the Operating Limit MCPR for each fuel type was made using standard GE reload methodology.

OI

.e An additional change is proposed in anticipation of a forthcoming 105%

flow analysis for Hatch 2 Cycle 3.

The proposed change limits the trip

/ '/ O setpoint of the rod block monitor to not exceed 107% power.

This change is W d6r)r!

inconsequential for core flow at or below 100% and prevents operation in an[W unanalyzed region for core flow above 100%.

The Plant Review Board and the Safety Review Board have reviewed the proposed changes to the Unit 2 Techi'al Specifications and have concluded that no changes in plant operation d t involved and that operation within the limits as revised by this submM.tal will maintain existing margins to 8203240224 820311 PDR ADOCK 05000366 P

PDR

GeorgiaIbwer A Director of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission March 11,1982 Page Two themal limits.

Thus, the proposed changes to the Technical Specifications do not increase the probability of occurrence or consequences of a previously analyzed accident or malfunction of equipment important to safety, nor has the possibility of a previously unanalyzed accident or malfunction of equipment been created.

Transient and accidert analyses were perfomed using approved codes.

Consequently, margins of safety have not been reduced.

The proposed change to the Technical Specifications are needed to support startup of the unit following the current refueling outage.

These proposed changes to the Unit 2 Technical Specifications are determined to be a Class III amendment.

The determination is attached as.

Consequently, a check for $4,000 is enclosed.

J. T. Beckham, Jr. states that he is Vice President of Georgia Power Company and is authorized to execute this oath on behalf of Georgia Power Company, and that to the best of his knowledge and belief the facts set forth in this letter are true.

GEORGIA POWER C0ffANY By k

g J. T. Beckham, Jf.

Sworn to and subscrib d bef e me this lith day of March, 1982 Dr2

/

[

tisfar$blic Netwy Pubik. Georgie, State et large DLT/mb y, c,,,,,,, ty; u, u, ne 3 Enclosure xc:

M. Manr/