ML20041G236

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept for Jan 1982
ML20041G236
Person / Time
Site: Kewaunee 
Issue date: 02/09/1982
From: Ruiter G
WISCONSIN PUBLIC SERVICE CORP.
To:
Shared Package
ML20041G234 List:
References
NUDOCS 8203190426
Download: ML20041G236 (4)


Text

. _.

.. =.

A Y ER AGE DA I LY UN IT POW ER LEV EL DOCKET NO-50-305 UNIT-KEWAUNEE COMPLETED BY-G.

H.

RUITER TELEPHONE-414-388-2560 X225 REPORT MONTH

.T A NU AR Y, 1982 AVERAGE DAILY DAY POWER LEVEL (MWE-NET) 1 514 2

514 3

517 1

4 513 l

5 513 6

263 7

505 8

513 1

513 10 513 11 514 12 513 13 514 518 14 i

15 514 16 514 17 514 18 518 19 514 20 514 21 514 22 514 23 517 24 500 25 484 26 501 27 505 28 514 29 518 30 514 31 518 l

8203190426 820209 PDR ADOCK 05000305 R

PDR

DOCKET 50-305 KEWAUNEE NUCLEAR POWER PLA NT

SUMMARY

OF OPERATING EXPERIENCE January, 1981 OPERATIONS:

On January 6, unit load was reduced for condenser water box inspections. The unit was returned to full load on January 7.

On Ja nuary 25, unit load was reduced to complete the monthly turbino stop valve test. The unit was returned to full load on the same day.

MAINTENANCE:

Repiaced a

sticking solenoid valve for a

SV exhaust fan danper control.

Pepaired a cracked weld on a charging pump relief r

valve.

overhauled a boric acid concentrates pump.

Repaired a service water leak on a containnent fan coil unit.

Cverhauled a charging pump.

l i

l P

l I

0PER 4T1NG D ATA REPORT EOCKET No-53-305 C05PLETED BT-C.

B. RUITER

(,

OPE R ATIN J

$TATUS TELEPHONE-414-388-2560 1225

(,

1 UNIT NAME KEWAUNEE e

e 2 REPORTING PERIOD JANUARY, 1982

  • NOTES

(,

e 3 LICENSED THEPE AL POW ER (MWT) 1650

  • The unit has been on line continuously
  • for 238 days as of the end of this reporting period.

A, 4 N A5EPLATE P ATING (GROSS MBE) 560 e

5" DESIGN ELECTSICAL BATING (NET MUE) 535

(,

6 MAEIM3M DEFEhDAELE CAPACITY (CROSS MUE) 538

(,

7 MAZIMUM DEPENCABLE CAPACITY (WET qur) 515 8 IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS NUMBER 3 TBSOUGH 7) SINCE L AST REPORT, GIVE RE ASONS

(,

Harimus Dependable Capacity gross and net values are changed based or. results of a capacity test performed January 4, 1982.

L, 9 PCdER LEVEL TO WHICH RESTPICTED, IF ANT (NET MUE) None to REASONS FOR RESTRICTIONS, IF ANY L

THIS 50578 TR-TO-DATE CD5DLATIVE 11 HOURS IN REFORTING PERIOD 744 744 66889 b

12 NU5 DER OF HOURS R EACTOR WAS CRITICAL 744.0 744.0 56745.9

(,

13 BEACTOR RESERVE SHUTD03B HOURS 0.0 0.0 2330.5 14 HOURS GENERATOR ON-LINE 744.0 744.0 55550.8 V

15 UNIT d ESERVE SUTDOWN BOURS L

0.0 0.0 10.0 15 GEOSS THEREAL ENERGY GENERATED (nsH) 7 '1203474 1203474 86010408 17 GROSS ELECTRICAL ENERGY GENER ATED (BW B) 392700 392700 28345100 18 NET ELECTRICAL ENERGY GENERATED (EsH) v;

374918 374918 26975175

'+

' 1 E 100. 0 100.0 83.1

. ' <. -+..

g, 19 UNIT SERVICE FACTOR 20 UNIT AVAILABILITY FACTOR

,'jf.*4 }.100.0 100.0 83.0

-m._ ~ ~Y,[-

.'s f.]

97.8 97.8 77.1 i

21 UNIT CAPACITY FACTOR (USING HDC NET) hh )-( 94.2 94.2 75.4 22 UNIT CAPACITY FACTOR (USING DER NET) '

7 s,

j

.% k#5 G.

'4 0.0 0.0 49 23 UNIT FOPCED OUTAGE RATE

.f.?f,{;

t g

24 SHUTDOWNS SCHEDULED OVER NEET 6 50NTRS (TYPE, DATE, AND DUR ATION OF EACH)

A refueling shutdown of 6-week doration is schedoled to start April 11, 1982.

j

'W.

l g,

25 IF SHUT 00vN AT END OF REPORT PLRIOD, ESTIMATED DATE OF START N

h 4 % ' % f Q %.J W y :+.UP - N/A Wn

=. ; '*-Ni:WW

' ~ T ' W.'

=.

9 L

UN IT S H U T;D 0 V W S A5 D PO If EB BEDUCTIO5 S G

a DCCKET No: 50-3C5 UNIT MARE: Kevaunee DATE: February 1,

1982

(

COMPLETED BY: G.

B. Ruiter TELEP50NE: 414-388-2560 m225 L

4 L

REPORT MONT8 - JANUARY, 1982 L

I NO. I D&TE ITTPE IDUR ATIONI RE ASON15ETHODI LER 53R8EB lSTS I CORPOW ENT l C09 MEETS I

l l

l l

L i

i i

i I

i I

I I

I I

I 1 1 1/ 6/828 F l O.0 1

8' I 5

-l N/A

.I HF 1 HTEICH I

1. A load reduction to 42% power was required to l I

I l

l l

1 1

I j

i pe rmit inspection of the Main Condenser I I

I I

I I

I I

I I

I waterboxes and the plugging of one condenser i l

i I

tube due to circulating water leakage into the i I

I I

I I

I

'I I

I I

condenser.

I I

I I

I I

I I

L i

I I

I I

I I

1 1

I I

=

i I

I

  • I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

L I

I I

I I

I I

I i

1 1

1 I

I I

I I

el I

i 1

I I

i 1

I I

I I

I I

I I

L i

I I

I I

I

'l I

I I

i I

i i

i I

I 1

1 I

I I

I I

I I

I I

.I i

1 1

I L

i i

i I

i 1

l I

I I

I I

I I

I I

I I ~_

I I

I I

I I

I I

I I

I I

I I

I L

I I

I I

I I

.I I

I I

i 1

1 1

1 1

1 1

I I

I I

I I

I I

I I

I i

i I

I I

b-1 I

I I

I I

ci i

i i

i i

l l

I I

I

-1 I

I I

I I

I I

I I

.I X*I. '. -

1 I

I I

L I

I I

I 1

i NI

-W.

I I

I I

I i

1 1

I I

dl...;

I I

I I

- Li t. 7/,. '

s I.. pr' I

I i

1 I

I I

I I

I I

I I

I L,

i I

I I

I I

1 I

I I

I I " ~Q ' l 4;%

I I

I I

I I

I I

I I

-4.1

'.,Y v

r..

I I

I I

  1. t

I I

I I

L i

I I.

I.

I I

i l a

a a

j

~

L TYPE EEASON

.4 BETHCD SYSTE5 & COMPosituT CODES

' h.b;:; C F: Forced A-Equipment Failure (Explain) f4.', _ _

1-Manual Fros 33 BEG-0161

,'Td pdel--

L S: Scheduled E-saintenasce or Test 2-sanual Scrat.

C-Refeling

?43 3-Automatic Scras D-Begtlatory Restriction Q }g/1 -

4 4-Continuations v

E-operator Training & Liceame' Esamination 5-Load sedoctions

%W %D 9-Cther F-Ad slaistrative (Explaia} %.c --

C-Cpera tional Error

(,

B-Cthet (Explain) e v.:;. jpw

_y g.pg. w.m- =.

.. y, w - y m.-

r.y y.

.