00 DEPARTMENT OF PflYSICs Seattle University fd4 SEATTLE, WASillNGTON 98122 TELEPilONE (206) 626-5400

, h,g [h 4,

C'.

A

-rw Docn[7 N

January 22, 1982 4

usq B

FEB j g bO2 >

.RCF'kED Ms. Bernice M. Kosla

' 'i S

~.~-

  • 4 Day Uranium Process Licensing Section FEB 0 3 1982 >

t Uranium Fuel Licensing Branch 7

1 s. nuctDR ucuuttoar -3 47Cg Division of Fuel Cycle and Material

  • T ?os s

Sa fety edfZ U.S. Nuclear Regulatory Commission k

Y g

C Washington, DC 20555 C

Dear Ms. Kosla:

In accordance with your letter of November 9,1981, below is submitted the information requested for processing the renewal of License No. SNM-589.

I. Data concerning Applicant, (70.22(a)(1))

N

a. Name: Seattle University U>

?

,. g c E W 6 0 h

b. Address:

12th Avenue and E Columbia Street a

1 g go@r '_

Seattle, Washington 98122 cq,B se 5

r,.q$* fd

c. Statt of Organization: Washington W.

N

d. Principal Officers:

%n Z(QC

m

~ _./

(1) William J. Sullivan, S.J., President Loyola Hall, Seattle University Campus United States Citizen (2) Gary A. Zinnerman, Ph.D.

Executive Vice President 401 100th Avenue NE Apartment 323 Bellevue, Washington 98004 United States Citizen (3) Marylou Wyse, Ph.D.

Acting Vice President for Academic Affairs 9515 31st Street, NW Seattle, Washington 98117

., hp p r q' U[

United States Citizen

,y v

.r t'

h.,Um k 8N

~

20212 8203090002 820111 PDR ADOCK 07000600 C

PDR

Ms. Barnico M. Kosla-

- January-22, '1982 Page Two-II. Location of-SNM (70.22(a)(2))

(1) When not in use, the four plutonium-beryllium neutron sources, totaling 155 grams of plutonium, are-stored in a white

cylinc
rical tank full of water.. The tank is 4 and 1/2 feet-in diameter and 5 feet :in depth..The sources, when stored, sit on a plastic platform; the platform is midway between the top and bottom of-the tank _; and the sources are nested together on the platform midway from the'outside cylindrical surface.

~

(2) We have on loan from NRC 900 slugs of 0.947% ' enriched uranium, totaling 2188118 grams; 896 of these slugs.are-in the sub-critical assembly and 4 of them are kept in a barred, doubly-locked cabinet. These are on the hall-level floor of Room 105.

~

III. Activities involving the use of SNM The subcritical assembly is used as an instructional tool.

Seattle University gives a course in the basic elements of reactor physics. The course consists of lectures in theory and experiments. The experiments deal with the basic parameters of reactors such as' Fermi Age, Diffusion' Area, 4

Bucklings, Multiplication Constant, and the poison effect as

.the basis of control.

l --

To operate the subcritical assembly, a plutonium-beryllium j

neutron source is'used. Time permitting, experiments with the de Pangher Meter are done (such as measuring neutron energies and doses as functions of distance); this ' requires

[

the use of plutonium-beryllium neutron' sources. The.sub-critical assembly is also used when students work on a special project when needed to meet curriculum requirements;-such as.

flux distributions under;special reactor conditions.

It.is described to visitors, such as visiting. groups of high school students; parents (on parents days),. special visitors, etc.

IV. Existing Licencse Number and Renewal Date (70.22(a)(3))

(1) SNM license expires: 2/28/81 (2) Renewal requested: January 6,1981.

V. Listing of SNM (70.22(a)(4))

(1) 2188118 grams (900 slugs) of.947% enriched uranium, in solid metal form of the following isotopic content:

a) 20722 grams of U-235 b) 2167396 grams.of U-238

. -.. ~

Ms. Barnice Kosla January 22, 1982 Paga Three (2) Plutonium-Beryllium neutron sealed sources; these were manufactured by Monsanto Research Corporation.

U" Serial No.

Plutonium Content Size (0.DxL, inches) 6 1088 5.20 x 10 45.27 grams 1.02 x 2.91 6

1089 1.76 x 10 15.24 1.02 x 1.45 6

1090 1.72 x 10 15.08 1.02 x 1.45 6

519 9.1 x 10 79.74 1.30 x 2.70 Total 155.33 The sourceg are alloys of PuBe2 3; they have a melting point of about 1750 C.

The amount of the above SNM has remained constant since acquired.

It has not been used in any way that required.its actual consumption, or transformation into any other form.

VI. Items under (70.22(a)(6)) are not applicable because of the nature of usage made of the SNM on loan to Seattle University.

VII. Items under (70.22(a)(8)) are not applicable since no SNM is consumed in its mode of application.

VIII. Audits and Inspections (70.55)

The following audits are made semi-annually:

a) inventory of the 900 slugs of uranium b) Seattle University has less than 350 grams of Plutonium in the four plutonium-beryllium neutron sources; an inventory report on this SNM is no langer required.

The inventory report on the SNM of enriched uranium is filed with the following organization :

a) Union Carbide Corporation-Nuclear Division b) CSD/DRGDP Site c) Nuclear Material Control-Mail Stop 19 Oakridge, Tennessee 37830

Ms. Bernice Kosla January 22, 1982 Page Four IX. Radiation Safety (10 CFR 20)

A. The Nuclear Subcritical Assembly laboratory houses:

1. The 900 slugs of enriched uranium slugs
2. -The four-plutonium beryllium neutron sources
  • 3. The gamma cell (Co-60), and
  • These are under state license.
1. The users of the laboratory are required to wear badges which are sensitive to gamma rays, x-rays, beta rays, and neutrons.
2. The badges are processed by Radiation Detection Company of Sunnyvale, California. Radiation Detection Company submits reports on the exposure received by the person using the badge.
3. Personnel monitoring reports are filed annually (10 CFR 20.202(a))

with:

Director of Management and Program Analysis U.S. Nuclear Regulatory Commission Washington, DC 20555.

4. Semi-annual radiation-level surveys are made of this ;aboratory, personal surveys are not applicable because of the nature of useage made of SNM.
5. Semi-annual wipe tests are made on the plutonium-beryllium neutron sources, Sr-90, gamma cells and the two, Ni-63 sources (the latter sources are housed in a gas chromatagraph machine in Room 601 of the Bannan Building).
6. The criterion limit in all wipe or swipe tests for contamination is 0.005 microcuries.
7. A state inspector, at intervals of two years, examines the reports on surveys, the badge reports, wipe and swipe tests results, license status.
8. Since the subcritical assembly is an instruction tool only, and is not a generator of power, no fuel is consumed, no waste is created in any of the three physical forms.

~

Ms. Bernice Kosla January 22. 1982 l

l Page Five X. Se w ity a) Entrance to the laboratory is through the hall-level door.

These doors are triply locked. Two locks are mechanical; the third lock is to an electric a 4 arm system which activates a loud bell and is also telephonically connected to the guard house (the guatd house is manned 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> a day). An unauthorized entrance by force activates the telephonic alarm to the guard house in addition to sounding a bell throughout the building.

The plant security officer is there upon notified immediately.

b) There are three (3) keys:

i. One turning the alarm off and on
11. Two different keys to the two mechanical locks c) The possessors of these are:
1. One set to the Director of the Nuclear Facility
11. One set to the Chairman of the Physics Department; and iii. One set to the Dean of Engineering and Science.

I apologize for the delay in getting this report to you and if'any further information is required, please let me know.

Sii.cerely,

- AQuk k.YOhU Frank A. Valente, Ph.D.

Professor Emeritus ZSC