PROPOSED TECFNICAL SPECIFICATION REFUELING OPERATIONS 3/4.9.7 CRANE TRAVEi.-SPENT FUEL AND UPPER CONTAINMENT FUEL STORAGE POOLS LIMITING CONDITION FOR OPERATION 3.9.7 Loads in excess of 1,140 pounds shall be prohibited from travel over irradicted fuel ossemblies in the spent fuel or upper containment fuei storage pool rocks.
APPLICABILITY: With irrodioted fuel ossemblies in the spent fuel or upper containment fuel storoge pool rocks.
ACTION:
With the requirements of the above specification not satisfied, place the crone load in a safe cor.dition. The provisions of Specification 3.0.3 ore not opplicable.
SURVEILLANCE REQUIREMENTS 4.9,7 Loads, other than fuel assemblies or control rods, shall be verified to weigh less than or equal to 1,140 pounds before travel over fuel assemblies in the spent fuel and upper containment fuel storage pools rocks.