ML20041B610

From kanterella
Jump to navigation Jump to search

Notification of 820216 Meeting W/Util in Bethesda,Md to Discuss Encl Meeting Agenda Re Steam Generator Review
ML20041B610
Person / Time
Site: Millstone 
Issue date: 02/10/1982
From: Conner E
Office of Nuclear Reactor Regulation
To: Clark R
Office of Nuclear Reactor Regulation
References
TAC-47577, NUDOCS 8202240351
Download: ML20041B610 (4)


Text

f) (,.'3 /1]S-C]fo

+

FEB 1 0 1982 to ro

_f

~~%

a (DocketNo.50-336) g/

3

'1 yy. l. S Y.

nl

i e,.

O I

~ e\\; C/?][/99 MEMORANDUtt FOR: Robert A. Clark, Chief-(O Operating Reactors Branch #3

~

'"We k s Division of Licensing

\\~ f khDN 4

.. s N

Na FROM:

E. L. " Monte" Conner, Project Manager g'ry.

,f^)

Operating Reactors Branch #3

<61 p'

Division of Licensing

SUBJECT:

FORTHCOMING MEETING WITH NORTHEAST NUCLEAR ENERGY C0!iPANY ON MILLSTONE,. UNIT NO. 2 STEAM GENERATOR REVIEW Time & Date:

9:00 AM, Tuesday February 16, 1982 Location:

P-422 Phillips Building Bethesda, Maryland

Purpose:

To discuss the enclosed meeting agenda in regards to steam generator review with flortheast Nuclear Energy Company.

Participants:

NRC NNECO Emett Murphy Fred Sears Conrad McCracken Leo Nadeau Vince Leung Joe Fackelmann Ted Shediosky Jim Kelly Monte Conner-Mike Cass Q4naldgrW b's E. L. " Monte" Conner, Project Manager Operating Reactors Branch #3 Division of Licensing Attachront:

As stated cc: See next page ome,p OR,B Q,: g,,,,,,,,

sun-e > E,C,gn,p,,e,r,fp,n,,,,

"r. 2/ /82

~~""

e2o224o351 saoato

$DRADOCK05000$

CIAL RECORD COPY usogonen-m.co unc ronu

SW4 9

8

'%' i UNITED STATES NUCLEAR REGULATORY COMMISSION

{

WASHINGTON, D. C. 20555 FEB 101982 Docket No. 50-336 MEMORANDUM FOR: Robert A. Clark, Chief Operating Reactors, Branch #3 Division of Licensing FROM:

E. L. " Monte" Conner, Project Manager Operating Reactors Branch #3 Division of Licensing

SUBJECT:

FORTHCOMING MEETING WITH NORTHEAST NUCLEAR ENERGY COMPANY ON MILLSTONE, UNIT NO. 2 STEAM GENERATOR REVIEW Time & Date:

9:00 AM, Tuesday February 16, 1982 Location:

P-422 Phillips Building Bethesda, Maryland

Purpose:

To discuss the enclosed meeting agenda in regards to steam generator review with Northeast Nuclear Energy Company.

Participants:

NRC NNECO Emmett Murphy Fred Sears Conrad McCracken Leo Nadeau Vince Leung Joe Fackelmann Ted Shedlosky Jim Kelly Monte Conner Mike Cass Nv

  • E. L. " Monte" Conner, Project Manager Operating Reactors Branch #3 Division of Licensing

Attachment:

As stated cc:

See next page e

p'.

cc: Docket File NRC PDR L PDR NSIC ORB #3 Rdg H'.'DEnton B. Grimes l

l Project Manager PMKreutze'r R. A. Clark OELD I&E Receptionist ACRS-10 NRC Participants

w y,

MEETING AGENDA STEAM GENERATOR REVIEW MILLSTONE UNIT N0. 2 FEBRUARY 16, 1982 1.

Introduction f

2.

Steam Generator Overview 3.

ECT Techniques 4.

Cycle 5 Inspection Results 5.

Analytical / Test'ing Ef fort 6.

Corrective Actions (Mechanical Plugs) 7.

Safety Analysis 8.

Operational Considerations 9.

Special Programs

10. Summary O

G e

-. -.. _ -.. _ - - -