Summary of Committee for Review of Generic Requirements 811203 Third Meeting Re Facilities,Equipment & Procedures to Cope W/Emergencies in Nuclear Power Plants,Per Reg Guides 1.97 & 1.23.Attendance List Encl
ML20040G176
Person / Time
Issue date: 12/07/1981
From: Stello V
NRC OFFICE OF THE EXECUTIVE DIRECTOR FOR OPERATIONS (EDO)
To: Eisenhutd G, Jordan E, Mausshardt D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE), NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS), Office of Nuclear Reactor Regulation
References
RTR-REGGD-01.023, RTR-REGGD-01.097, RTR-REGGD-1.023, RTR-REGGD-1.097 NUDOCS 8202110391
Download: ML20040G176 (3)


Text

-.

[durug V

UNITED STATES N

NUCLEAR REGULATORY COMMISSION

~

h WASHINGTON, D. C. 20555 k.....,/

DEC _ 71981 P

.i1 F

~"'

4' MEMORANDUM FOR:- Darrell G. Eisenhut, NRR Edward L. Jordan, IE 4

Donald B. Mausshardt, HMSS M.

Robert M. Bernero, RES N7O s

C1emens J. Heltemes, Jr., AE0D

,7 9

U 1

Joseph Scinto ELD 9

'D FROM:

Victor Stello, Jr., Chairman G

Committee to Review Generic Requirements

,i

SUBJECT:

MINUTES OF CRGR MEETING NUMBER 3

' The Committee to Review Generic Requirements met on Thursday, December 3, 1981.

All CRGR members were present, and several staff members attended the first part of the meeting (Enclosure 1).

1 The entire meeting was devoted to the topic of " Facilities, Equipment and Procedures to Cope with Emergencies in Nuclear Power Plants." The Committee found that there was no consensus among the principal staff.

t concerning the precise requirements for the Safety Parameter Di, splay System (SPDS), the Technical Support Center (TSC) and the Emergency Operations Facility (E0F). There was evidence that the existing NUREG documents purporting to represent requirements for the facilities had not been carefully coordinated, and there was evidence that the proposed SPDS in' tallation schedules had not been integrated Ith the Control s

Room Design Reviews on a schedule that is realistically achievable at operating plants. Correspondence and discussions with industry repre-sentatives prior to the meeting revealed that, in the face of this i

confused picture in NRC, wo'rk in many of these areas has virtually stopped at some plants awaiting clearer NRC guidance on.the precise requirements.

't The Committee decided that immediate action is needed to clarify the requirements and ensure coordination among the various activities. The DEDR0GR staff has been tasked to take the lead, working with NRR, IE and RES representatives, to identify and integrate the basic requirements 6 I for the SPDS,.TSC, E0F, and the related requirements for the Control g5 /

1 Room reviews, revisions to the Emergency Operating Procedures and re-a quirements from Reg. Guides 1.97 and 1.23, and to report these basic f

requirements to the CRGR at its next meeting on December 10, 1981. The Committee intends-to review the requirements and develop recommendations om ~7 eld, for further EDO action.

8202110391 820207

'PDR REVOP NROCROR PDR

.~.

.r C

u-*

I.*

rf DEC 7 1981 2-CROR Members i

e The EDO was informe'd.of the Comittee's actions (Enclosure 2).

l uriguai Signed by V, Stello y '

Victor Stello," Jr., Chairman Comittee to Review Generic Requirements

Enclosures:

1.

List of Attendees 2.

Memo Stello to Dircks, Emergency Response Facilities cc: Office Directors Regional Ad?.ini.strators Distribution:

VStello TEMurley DEDR0GR cf Central File

'1j PDR [WM

/

i i

nlC - OC[

j omett.DdRbbS/S/D.

.DEDR0SR........

suanue >.a.Or.1ey.:b.g.

..VS.t.e.l.l.o.......

ouc 3..12/.4/B.1........12/..../B.l.......

,a l

I n'

4 LIST'0F ATTENDEES - CRGR MEETING tlUMBER 3 Don Mausshardt, CRGR Bob Bernero, CRGR Ed Jordan, CRGR Vic Stello, CRGR Joe Scinto, CRGR Jack Heltemes, CRGR-Darrell Eisenhut, CRGR Tom Murley, DEDR0GR Staff Walt Schwink, DEDROGR Staff Steven L. Ramos, EPDP-IE Edward William, EPDB-IE Joel Kramer, NRR Frank Lomax, IE Tom Cox,DEDR0GR Staff Ken Perkins, ED0 Liz Quinn, DEDR0GR Staff Shelly Schwartz, IE Ed Blackwood, DEDR0GR Staff Mat Taylor, DEDR0GR Staff Beth Hayden DEDROGR Staff Al Hintze, RES M. Williams, NRR Warren Minners, NRR L. Brown, RES Leon Beratan, RES John Olshinski, Region II Karl Goller, RES Roger Mattson, NRR Steve Hanauer, NRR Dan Garner, NRR Jim Sniezek, IE 6

e

~

v p.

DEC 7 1531 MEMORANDUM FOR: William). Dircks Executive Director for Operations FROM: ' -

Victor Stello, Jr., Chaiman Comittee to Review Generic Requirements

SUBJECT:

EMERGENCY RESPONSE FACILITIE5 c

On December 3,1981, the CRGR met to review ilRC's activities in the broad area of Emergency Response Facilities, Equipment and Control Room Design Review. The Comittee found that there was no consensus among the principal staff concerning the precise requirements for the Safety Parameter Display System (SPDS), the Technical Support Center (TSC) and i

~.

the Emergency Operations Facility (EOF). There was evidence that the existing NUREG documents purporting to represent requirements for the facilities had not been carefully coordinated, and there was evidence that the proposed SPDS installation schedules had not been integrated with the Control Room Design Reviews on a schedule that is realistically achie'vable at operating plants. Correspondence and discussions with industry representatives prior to the meeting revealed that, in the face

'of this confused picture in HRC, work in many of these areas has virtually stopped at some plants awaiting clearer NRC guidance on the' precise requirements.

The Co:miittee decided that imediate action is needed to clarify the requirements and ensure coordination among the various activities.

The DEDROGR staff has been tasked to take the lead, working with NRR, IE and RES representativest to identify and integrate the basic requirements for the SPDS, TSC, EOF, and the related requirements for the Control t

Room reviews, revisions to the Emergency Operating Procedures and requirements from Reg. Guides 1.97 and 1.23, and to report these basic requirements to the CRGR at its next meeting on December 10, 1981. The Comittee intends,to review the requirements and develop recomendations for further EDO action. In the meantime, the.Comittee recommends that you advise the Director of RES to withdraw tiie proposed change to 10 CFR 50 Appendix E.Section IV.E., which is currently circulating in concurrence.

and. that you advise the Director of NRR to exercise caution in issuing staff evaluations or conclusions for operating reactors and ongoing case-work reviews until these requirements are clarified.

Origi=al signedy Yicter Stell.o.y Victor Stello, Jr., Chairman Comit' tee to Review Generic cc:. CRGR Members Am 61 dm

_a "Of-t' Q' J '

- J. @

l

-