4 DISTRIBUTION:
Docket File bcc:
'LB#1 Rdg.
TERA JYoungblood PDR SChesnut LPDR KKioer NSIC JAN 2 21982 MRushbrook TIC DEisenhut ACRS (16)
SHanauer Docket Nos.: STfl 50-454 RMa ttson and STN 50-455 JKramer RVollmer RHartfield, MPA Mr. Louis 0. DelGeorge OELD Director of Nuclear Licensin9 OIE Commonwealth Edison Company Post Office Box 767 Chicago, Illinois 60690
Dear Mr. DelGeorge:
Subject:
Request for Additional Geological Information for Byron As a result of our review of the Byron FSAR, we have identified a need for additional geological information. The request for informatior, is included as Enclosure 1.
Please respond to this report as soon as possible to allow inclusion of the information in the SER. For further information or clarification, contact the Byron Project Manager, Steve Chesnut.
A i ; n,,
f Qg Sincerely,
/k';
i47.0
/
I'j m d 68E'k Oric!.m1 sir.nea by:
7 P. J. Lun21dood
-,wrc'A - r B. J. Youngblood, Chief
' " ~
D QM.,h;m Licensing Branch No.1 2
Division of Licensing N
Enclosure:
il 5 As stated cc w/ encl.: See next page lac ' cp:rting end/or recordkeeping r uirener.ta centained in this letter L.'ce.t ie.ver than ten respondents ;
~
thucroro. 00.3 clearance in not required r.nde r P.L.93-511. "
8202110165 820122 PDR ADOCK 05000454 l
A PDR p
omec > ?L.:.LBd.
,E,;,L,B.
1,,,
,,, D.L,;IfMk,,,
ILK.i.9. rLl.9..
SCh BJY, {ib,],9,0.(t e
suwes >
1/22/82 1
1 82 omy
..g.............
OFF1ClAL RECORD COPY usam mi-33m unc ronu ais no-ao) Nacu oua
Mr. Louis 0. DelGeorge Director of Nuclear Licensing Commonwealth Edison Company Post Office Box 767 Chicago, Illinois 60690 cc: Mr. William Kortier
' Mr. James G. Keppler Atomic Power Distribution U. S. NRC, Region III Westinghouse Electric Corporation 799 Roosevelt Road P. O. Box 355 Glen Ellyn, Illinois 50137 Pittsburgh, Pennsylvania 15230 Paul M. Murphy, Esq.
Isham, Lincoln & Beale One First National Plaza 42nd Floor Chicago, Illinois 60603 Mrs. Phillip B. Johnson 1907 Stratford Lane Rockford, Illinois 61107 Ms. Bridget Little Rorem Appleseed Coordinator 117 North Linden Street Essex, Illinois 60935 Dr. Bruce von Zellen Department of Biological Sciences Northern Illinois University DeKalb, Illinois 61107 Mr. Edward R. Crass Nuclear Safeguards and Licensing Division Sargent & Lundy Engineers 55 East Monroe Street Chicago, Illinois 60603 Myron Cberry, Esq.
Cherry, Flynn and Kanter 1 IBM Plaza, Suite 4501 Chicago, Illinois 60611 Mr. William Fourney U. S. Nuclear Regulatory Comission Byron / Resident Inspectors Office 4448 German Church Road Byron, Illinois 61010 Ms. Diane Chavez 602 Oak Street, Apt. #4 Rockford, Illinois 61108
W Enclosure l' Byron
-360.1: At the meeting on December 22, 1981 on Geotechnical questions, your geologic consultants stated that the glacial till overlying the bedrock at th_e site is now considered to be entirely from the Illinoisan stage of the Pleistocene, and that no Wisconsinan till is present in.the site locality.
Please discuss this determination, providing the bcses',for it, the absolute age with supporting evidencq, and all relevant references.
1
\\
k
~
'a 4
s s
S L
s.
r 9
see e
e k
O p
0 0
e
~