Amends 36 & 16 to Licenses NPF-04 & NPF-07,respectively, Revising Tech Specs to Allow Increase in Enrichment of New & Spent Fuel to 4.1% U-235
ML20040F965
Person / Time
Site: North Anna  
(NPF-04-A-036, NPF-07-A-016, NPF-4-A-36, NPF-7-A-16)
Issue date: 01/19/1982
From: Clark R
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20040F966 List:
References
NUDOCS 8202110005
Download: ML20040F965 (10)


Text

.

gge agCg f

o, UNITED STATES f

NUCLEAR REGULATORY COMMISSION

{ y.g,v(/g i WASHINGTON, D. C. 20555

.p,-

/;- l

%l y,<

VIRGINIA ELECTRIC AND POWER COMPANY DOCKET NO. 50-338 NORTH ANNA POWER STATION, UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 36 License No. NPF-4 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by. Virginia Electric and Power Company (the licensee) dated March 6, 1981, as supplemented March 26, 1981, and Auaust 15, 1981 complies with the standards and reauirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the' health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

0202110005 820119 PDR ADOCK 05000339 P

PDR

t.

2.

Accordingly, the license is r.1 ended by changes to the. Technical Specifications as indicated in the attachment to this license amendment and paragraph 2.D.(2) of Facility Operating License No. NPF-4 is hereby amended to read as follows:

t (2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.36, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

2 3.

This license amendment is effective as of the date of its issuance.

i FOR THE NUCLEAR REGULATORY COMMISSION c-g.

R ert A. Clark, Chief Operating Reactors Branch #3 Division of Licensing 1

Attachment:

Changes to the Technical Specifications i

Date of Issuance: January 19, 1982 I

4 L

f l

4

ATTACHMENT TO LICENSE AMENDMENT AMENDMENT NO. 36 TO FACILITY OPERATING LICENSE NO. NPF-4 DOCKET NO. 50-338 Replace the following page of the Appendix "A" Technical Specifications with the enclosed page as indicated. The revised page is identified by Amendment number and contains /ertical lines indicating the area of change.

The corresponding overleaf page is also provided to maintain document completeness.

Pages 5-4 e

s e

c

9 8

I 5

i

~

g j

E B

j b

Ell

(

/

n g1, k

  • l I00 2

2

~

E q

i Mstes I

+

J

'g gp r--

'S

' s.

Nu

$ h([f, A

~

7 xzy a

~

fo v

=

E 5;

~

{

/

l

- - ~.

NORTH ANNA ~ UNIT 1 5-3

DESIGN FEATURES DESIGN PRESSURE AND TEMPERATURE 5.2.2 The reactor containment building is designed and shall be maintained for a maximum internal pressure of 45 psig and a temperature of 280 F.

5.3 REACTOR CORE FUEL ASSEMBLIES 5.3.1. Tha reactor core shall contain 157 fuel assemblies with each fuel assembly containing 264 fuel rods clad with Zircaloy-4.

Each fuel rod shall have a nominal active fuel length of 144 inches and contain a maximum total weight of 1780 grams uranium. The initial core loading shall have a maximum enrichment of 3.2 weight percent U-235.

Reload fuel shall be similar in physical design to the initial core loading and shall have a maximum enrich-ment of 4.1 weight percent U-235.

l CONTROL R0D ASSEMBLIES 5.3.2 The reactor core shall contain 48 full length control rod assemblies.

The full length control rod assemblies shall contain a nominal 142 inches of absorber material. The nominal values of absorber material shall be i

~

80 percent silver,15 percent indium and 5 percent cadmium. A1.1 co'ntrol~ rods shall be clad with stainless steel tubing.

5.4 REACTOR COOLANT SYSTEM DESIGN PRESSURE AND TEf1PERATURE 5.4.1 The reactor coolant system is designed and shall be maintained:

NORTH ANNA - UNIT 1 5-4 Amendment No. 76, 27,36

[

UNITED STATES e '.e t I

'o NUCLEAR REGULATORY COMMISSION y g:t's *i o VV ASHINGTON, D. C. 20555

,. j

'%? f?

eo a

/

o VIRGINIA ELECTRIC AND POWER COMPANY DOCKET NO. 50-339 NORTH ANNA POWER STATION, UNIT NO. 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.16 License No. NPF-7 l.

The Nuclear Regulatory Commission (the Commission) has found that:

A'.

The application for amendment by Virginia Electric and Pc.cr Ccmpany (the licensee) dated March 6, 19R1, as supplemented March 26, 1981, 1981 complies with the standards and. requiraments and August 15, Energy Act of 1954, as amended (the Act) of the Atomic an'd the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in confonnity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this anendment can lie conducted without endangering the health and safety.of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

4

. 1 2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the sttachment to this license amendment and paragraph 2.C.(2) of Facility Operating License I

No. NPF-7 is hereby amended to read as follows:

(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.16, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION M

'c u.

Robert A. Clark, Chief Operating Reactors Branch #3 Division of Licensing

Attachment:

Changes tto the Technical Specifications Date of Issuance: January 19, 1982

ATTACHMENT TO LICENSE AMENDMENT AMENDMENT NO. 16 TO FACILITY OPERATING LICENSE NO. NPF-7 DOCKET NO. 50-339 Replace the following page of the Appendix "A" Technical Specific'ations with the enclosed page as indicated.

The revised page is identified by Amendment number and containsvertical lines indicating the area of change. The corresponding overleaf page is also provided to maintain document completeness.

Pages 5-4 I

s e

i g

4 e

i I

t f

t l

I w

==.

R

}5 s

~,

{

5

?

r

)

=

t y}

"l!f 1 y e

a saa R

a f

g, u

s a.,

P 3

s l

=

's~ i sg..

s~

'N

+

. i:..

+

V l

'f

s

- f la n

i 4

I~

k;%

{

~

}

[]11 I

/

n 4

np;l g-i D

J:

l N.,

5 f

i 1

/

\\

(

b h

g

~x~,

C v

=

l l ~-

o

/

~

NORTH ANNA - UNIT 2 5-3

DESIGN FEATURES 5.3 REACTOR CORE-FUEL ASSEMBLIES 5.3.1 The reactor core shall contain 157 fuel assemblies with each fuel assembly containing 264 fuel rods cicd with Zircaloy-4.

Each fuel rod shall have a nominal active fuel length of 144 inches and contain a maximum total weight of 1780 grams uranium. The initial core loading shall have a maximum enrichment of 3.2 weight percent U-235. Reload fuel shall be similar in physical design to the initial core loading and shall have a maximum enrich-ment of 4.1 weight percent U-235.

l CONTROL ROD ASSEMBLIES 5.3.2 The reactor core shall contain 48 full length control rod assemblies.

The full length control rod assemblies shall contain a nominal 142 inches of absorber material. The nominal values of absorber material shall be 80 percent silver,15 percent indium and 5 percent cadmium.

All control rods shall be clad with stainless steel tubing.

5.4 REACTOR COOLANT SYSTEM DESIGN PP.:SSURE AND TEMPERATURE 5.4.1 The reactor coolant system is designed and shall be maintained:

d.

In aCCordance with the code requirements specified in Section 5.2 of the FSAR, with allowance for normal degradation pursuant to the applicable Surveillance Requirements, b.

For a pressure of 2485 psig, and c.

For a temperature of 650 F, except for the pressurizer which is 680 F.

VOLUME 5.4.2 The total water and steam volume of the reactor coolant system is 9957 + 10 cubic feet at a nominal T,yg of 525 F.

NORTH ANNA - UNIT 2 5-4 Amendment No. 8,16 J