ML20040F566

From kanterella
Jump to navigation Jump to search
IE Safeguards Insp Rept 70-1257/82-01 on 820118-20.No Noncompliance Noted.Major Areas Inspected:Records & Repts,U Hexafluoride Cylinder Weighing Sys & Sampling of SNM at Various Process Stages.Details Withheld (Ref 10CFR2.790)
ML20040F566
Person / Time
Site: Framatome ANP Richland
Issue date: 02/01/1982
From: Brock B, Norderhaug L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
Shared Package
ML20040F560 List:
References
70-1257-82-01, 70-1257-82-1, NUDOCS 8202090350
Download: ML20040F566 (1)


Text

.

1 The information on this page is considered to.be appropriate i

for public disclosure pursuant to 10 CFR 2.790.

U. S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT Region V Report No. 70-1257/82-01 (E-V-477)

Dock'et No. 70-1257 License No. SNM-1227 Safeguards Group 1

Licensee:

Exxon Nuclear Company 2101 Horn Rapids Road Richland, Washington v

Facility Name:

Inspection at:

Richland, Washington Inspection Conducted:

January 18-20, 1982 Date of Last Material Control and Accounting Inspection:

~

~

Type of Inspection: Announced Special Safeguards' A

In'spectors:

B. L. Bro k, Chemist Date Signed

$[/[%

Approved by:

1. R. hor'derfiaug, Dief, SafttftraR anch Date Signed Inspection Sumary:

Areas Inspected: Observation of IAEA ad hoc inspection of the licensee's records and reports the licensees UF cylinder weighing system and sampling of SNM _at 6

various process stages.

The inspection involved 22 inspector-hours onsite by one inspector.

No items of noncompliance were identified.

8202090350 920202 PDR ADOCK 07001257 C

PDR