EtNIR0t4 ENTAL EMERGE?CY KIT RADIOLOGICAL EQUIRC!T EPIP 550-2 TABLE OF CONTENTS PAE DATE REVISION SECTION TITLE 1
DEC 15 1981 1
Table of Contents 2
DEC 15 IS81 1
A.
Purpose B.
References C.
Prerequisites D.
Precautions E.
Limitations & Actions 3
DEC15 set 2
i F.
Procedure G.
Checklist H.
Technical Specification / References 4
DEC 15 1c81 2
Attachrr.ent A Attachment B 5
DEC 15 1981 0
6 DEC 15 581 0
7 DEC 15 1981 -
O Attachnent C l
l This precedure contains 7 pages.
)
I 004E 8201220238 820/04 0007A hDRADOCK 05000295 p g /2-/T-il PDR
. ~
EPIP 550-2 Rev. 2 DEC 151981 EtNIRUNENTAL EERGENCY KIT RAOICLOGICAL EQJIPENT A.
RJRPOSE The purpose of this procedure is to outline the equipment to be maintained in the envircrvnental emergency kits and in the Emergency Operations Facility (ECF). The procedure also addresses special tests and surveillance requirements.
8.
REFEREPCES 1.
Generating Station Emergency Plan (GSEP) t EPIP 550-1 "On-Site Non-Radiological Emergency Response Equipment" 2.
3.
EPIP 550-3 " Radiological Supplies for Medical Emergencies" EDIP 550-4 "On-Site Radiological Emergency Response Equipment" 4.
5.
EPIP 550-5 "TSC and OSC Radiological Supplies" C.
PREREQJISITES None D.
PRECAUTIONS None E.
LIMITATIONS & ACTI0tG 1.
There are 2 environmental emergency kits, located in the emergency trailer.
2.
No equipment in the environmental kits nor the EOF should be needed for en-site radiological purposes. Such equipment is referenced in EPIP 550-4 and EPIP 550-5.
The Rad Chem Supervisor or his desiglee will be responsible for 3.
documentation and control of these supplies.
2 C046E CC07A 1
EPIP 550-2
~
~
Rev. 2
~
DEC i5 1961 F.
FROGOURE 1.
Cnce per month, check the oil and gas of the emergency generators (located near the kits in the emergency trailer). Start and run the generators for thirty (30) minutes. Note any abnormalities on Attachment A.
2.
Once per month, perform a battery check of the radiaticn detectors and verify they have been calibrated within the quarter. Inspect the probes for camage. Fill out the appropriate informaticn on Attachment A.
3.
Verify the self reacers have been calibrated per requirements of RP 1250-3. Test the dosimeter charger. Fill out the appropriate information in Attachment A.
Once per quarter, perform an inventory of the supplies is cutlined 4.
in Attachments B and C.
5.
Return appropriate forms to the rad / chem foreman. The rad / chem foreman shall correct any defects indicated in Attachnent A and shall replace any missing items indicated in Attachment B and C as soon as possible.
G.
CHECXLIST Attachment A, " Equipment Tests" Attachtent 8, " Environmental Emergency Kits" Attachment C, "ECF Radiological Suppliesa H.
TECHNICAL SPECIFICATION REFERENCES None 3
004E CC07A
~
N
~
~
EPIP 550-2 Rev. 2 DEC 151981 ATTACl+ENT A EQUIPMENT TESTS Emergency Generators: Monthly Check oil and gas, start and run. Repcrt and note abnormalities below.
2KW Generator:
Coments:
Environmental Kit Eculoment: Quarterly Calibration Type Serial Number Batt Check Date Ionization Chambers G4 Pulse Ratemeter Self Readers Dosimeter Charger Physical Check of Probes Undamaged Replaced Date Initials i
4 004E OC07A
O sE*
EPIP 550-2 Rev. O DEC 15 1981 ATTACHIENT 8
/
ENVIR0teENTAL ElERGENCY KIT EQUIP!ENT DESCRIPTION Quantity Quantity (D4ENTS Required Present Ion Chamber (range to 50 R/h) 1 1
Count Rate Meter 1
G-M Probe 1
Alpha Probe Self Reading Dosimeter (200M) 3 Self Reading Dosimeter (IR) 10 Self Readina Dosimeter (ICR) 4 Dosimeter Charger w/ batteries 1
1 Stoo Watch 1
I Comaass 1
Pocket Knife Check Source (Cs-137, 8 UC1) 1 Film Badges (Beta, Gamma. X Ray) 12
~
1 Environs Station Key Fuses for Air Samo (61/4 & 15 Amo) 5 ea 3
Flashlights w/ batteries Masking Taoe (2" roll) 1 Orange Fluorescent Paint Scray Cans 2
SH-4 Samole Holder for HP-210 Probe 1
1 Scissors 1
Duct Tace (Roll) 1 Smears (Box)
Silver Zaolite Air Samole Cartridges 20 Particulate filters (47mm) 50 Rad Barrier Ribbon (50 yd Roll) 1 Plastic Surgeon's Gloves (pair) 15
++
Radiation Sicns Terri Towels (75/cak) 2 1
Liter of Detergent Filter Medium Holders (clastic) 25 100 Samole Labels
++ - Various 5
0@E' 0007A
EPIP 550-2 Rev. O DEC H M ATTACFtENT B (Continued)
ENVIR0teENTAL EMERCEtCY KIT EQUIPENT DESGtIPTION Quantity Quantity COMPENTS Recuired Present 2
Tweezers Plastic Bags (Medium Size) f Soil, Vegetation & Water Sample Kit 10 (3 Bottle Set for Collecting Samo) 1 Shovel 9 Volt Batteries (Scare) 5 j
"D" Size Batteries (Scare) 12 "AA" Size Batteries 2
3 Full Face Mask Charcoal / Particulate Filters 6
1 Soiral Note Book Pens (Black, Felt Tio) 2 Permanent Marker (Black) 2 1
EG Procedures 1
EPIP's Radeco Air Sama w/47mm cart / cart head 2
First Aid Kit 1
12 Highway Flares Tool Kit (Pry Bar, Screw Drivers, 1
Large Hammers, Pliers)
Mac (M Prints) 2 Mac (State Drawino) 1 1
Radio Belt r
Stake (4') For Supporting Air Sampler 1
Off The Ground (near kit)
Anti C Clothing Set (Coveralls, Hood 3
Rubbers, Scoties, Gloves & Liners)
Rain Suit (Yellow Plastic) 3 6' Ladcer (located near kit) 1 Gas Generator (located near kit) 2 l
Potassium Iodide Tablets 10 l
- + - Various i
RCT Initials Date 6
004E 0007A
EPIP 590-2
~
Rev. 0 DEC15 561 ATTACtNENT C EMERGENCY CPERATICNS FACILITY, RADIOLOGICAL SUPPLIES DESCRIPTION Quantity Quantity '
COMMENTS Reouired Present Anti C Clothino Set, various sizes
- 30 30 Surceans' Caos Cotton Glove Liners (Scares) 15 or Rubber Gloves (Scares) 15 c 30 or Surcean's Gloves 15 Half Masks Full Masks
'15 Particulate / Charcoal Filters 60 Potassium Iodide Tablets 250 Film Badoes (< 4 me. old) w/ holders 30 0-500 mR self readers 15 0-1000 mR self readers 15-Dosimeter Charger 1
Eberline RM-16 1
HP 210 or 260 Probe w/ samole holder 1
l Dose Rate Instrument 1
PING Air Samoler w/ sucolies 1
1 00CM Environmental EPIP's 1
Timekeecino Sheets 5
Survey Sheets I
10 Anti-C Clothing Sets Include: Coveralls
+
Booties Ruobers Glove Liners Rubber Gloves Initials Date FINAL CC46E 7