Text
f
~o e
.?
~
Q C-d67
~
gkggg January 5,1982 o*ro
.Q 13:82:5 m acav anca vo Los Alamos NationalLaboratory u = ston: 576 (505) 667-5150 Lcs Alamos,New Mexico 87545 1ste, oue.
Energy Division e
A fiECUiVED Mr. Robert Clark, Chief r
Operating Reactors Branch 3 2
. gN, ;
Division of Licensing Office of Nuclear Reactor Regulation N gammer Nuclear Regulatory Commission m
Washington, D.C.
20553 9,
/j
Dear Mr. Clark:
Enclosed are two copies of the report concerning our review of the Public Service Company of Colorado proposed Inservice Inspection (ISI) program for the Fort St. Vrain High-Temperature Gas-Cooled Reactor. The work embodied in the report was carried out by Advanced Science and Technology Associates (ASTA) under subcontract tc the Los Alamos National Laboratory.
We have reviewed this report and concur.with the findings and recommen-dations specified by ASTA. You may wish to direct your attention initially to-the Executive Summary that gives recommendations concerning the Public Service Company of Colorado (PSCo) Inservice Inspection program submittals for the five safety areas that were reviewed.
We are also forwarding the report to PSco for their comments.
Except for minor clarification that you or PSCo may wish to have included in the final report, we consider the milestone on the ISI task to be met.
If you have any questions, please call me at FTS-843-5150.
Sincerely yours, Charles A. An on, Group Leader Advanced En ineering Technology
Enclosure:
a/s J. Jackson /M. Stevenson, Q-DO, M.S. 561, w/o encl.
R. Haarman, EP/NP, M.S. 671, w/o encl.
G. Kuzmycz, NRC, (1)
L. Brey/M. Holmes, PSCo, (3) 0 I
k30206:8201OS" 1
h DOcw 05000g6 i
G An Equal Opportunity Employer /Operatad by University of Canfornia
~
.