Notice of Violation from Insp on 801006-810114
ML20039E333
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 12/23/1981
From: Robert Carlson
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20039E323 List:
References
50-213-81-20, NUDOCS 8201070164
Download: ML20039E333 (1)


Text

m APPENDIX A NOTICE OF VIOLATION Connecticut Yankee Atomic Power Company License No. DPR-61 Hartford, Connecticut As a result of an investigation conducted from October 6, 1980 to January 14, 1981 of the circumstances surrounding the transportation and use of the Model No. NFS-4, Serial No. NAC-lE cask shipped from your facility in Haddam, Connecticut on May 1, 1980, and in accordance with the " Criteria for Enforce-ment Action For Failure to Comply with 10 CFR 71" we sent to you on December 3, 1979, the following item of noncompliance was identified:

10 CFR 71.12(b)(1)(ii) states, in part, that a general license is hereby issued to persons holding a general or specific license pursuant to this chapter, to deliver licensed material to a carrier for transport in a package for which a certificate of compliance has been issued by the Commission's Director of Nuclear Material Safety and Safeguards, provided that the person using the package complies with the terms and conditions of the certificate.

Certificate of Compliance No. 6698, Revision 9, dated December 12, 1979, which is applicable to the Model No. NFS-4, Serial No. NAC-lE cask, states in Condition 5(b)(2) that the maximum quantity of material per package will not exceed a decay heat generation of 2.5 Kw.

Contrary to the above, on May 1,1980, the Model No. NFS-4, Serial No. NAC-lE cask, loaded with failed fuel bundle H07, wss delivered to a carrier for transport with a decay heat generation in cxcess of 2.5 Rw (2.97 to 3.51).

This is a Severity Level III item of noncompliance.

Dated nF0 231981 h

Robert T. Carlson, Director Enforcement anJ I!vestigation Staff 0FFICIAL RECORD COPY 8201070164 811223 DR ADOCK 05000213 PDR I