ML20039D130
| ML20039D130 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 11/30/1981 |
| From: | Bellmore C, Hillman R, Maciolekblake Battelle Memorial Institute |
| To: | |
| Shared Package | |
| ML20039D128 | List: |
| References | |
| NUDOCS 8112310348 | |
| Download: ML20039D130 (25) | |
Text
.
4 i
l j
PROGRESS REPORT FOR THE TWEIITY-SIXTH QUARTER 4
Y on i
I 2
l i
i STUDY OF WOODB0RER POPULATIONS IN RELATION T0 i
OYSTER CREEK GEf1ERATING STATION i
to GPU NUCLEAR November 30, 1981 I
i l
by N. ilaciolek-Blake, C.I. Belmore, and R.E. Hillman Report No. 15091 August 22 to November 20, 1981 l
BATTELLE New England itarine Research Laboratory Duxbury, Massachusetts 02332 Battelle is not engaged in research for advertising, cales promotion, or publicity purposes, and this report may not be reproduced in full or in part for auch purpocec.
8112310348 811228 I
PDR ADOCK 05000219 R
PDR.
l 4
ll TABLE OF CONTENTS Page EXECUTIVE
SUMMARY
i INTRODUCTION........................................................
1 i
PROCEDURES AND INTERIM DATA.........................................
1 I
Exposure Panels...........................................
1 Wa t e r Q u a l i ty.............................................
12 i
l Teredinid Gonadal Development Studies.....................
12 LIST OF TABLES Table 1.
Geographical Locations of Exposure Panel Arrays in Barnegat Bay, New Jersey.................................
3 i
Table 2.
Incidence of Teredinidae in Panels Removed September 9-10, 1981...............................................
6 Table 3.
Incidence of Teredinidae in Panels Removed October 6-7, 1981................................................
8 i
Table 4.
Incidence of Teredinidae in Panels Removed November 3-4, 1981................................................
10 Table 5.
Incidence of Limnoria in Panels Removed September, i
October, and November, 1981..............................
11 1
l l Table 6.
Water Quality at Exposure Panel Stations, September 9 - 1 0, 1 9 81...............................................
13 Table 7.
Water Quality at Exposure Panel Stations, October 6-7, 1981................................................
14 Table 8.
Water Quality at Exposure Panel Stations, November 3-4, 1981................................................
15 Table 9.
Condition of Gonads of Teredinid Borers Removed from Exposure Panels in Barnegat Bay from August through October, 1981....................................
16 I
LIST OF FIGURES Figure 1.
Outline of Barnegat Bay Showing Geographical Loca tions o f Exposu re Panel s............................. 2
I EXECUTIVE
SUMMARY
This progress report presents data for field and laboratory work during the period August 22 to November 20, 1981.
During that time, three field trips were made to retrieve and l
replace long-and short-term pancls at each of 20 stations, and to measure temperature, salinity, pH and dissolved oxygen. All work was accomplished, but the entire rack of panels was missing at Station 13 (Rocknak's Yacht Basin, Cedar Creek) in October, and we were requested to remove the rack
{
at Station 16 (Berkeley Yacht Basin, Seaside) in November.
The rack was 1
replaced at Station 13 in November, and we will locate a new site for l
Station 16 in December.
Laboratory analysis of the panels showed Teredo bartschi present l
at Oyster Creek Stations 6 and 7 in September, October and November panels, and a single specimen at Station 10A in November.
T. navalis continues l
to be most corrmon at Station 1, near Barnegat Inlet. Bankia gouldi occur-I red in low numbers at several stations along the western shore of Barnegat Bay Panels from several stations had no shipworms present.
Limnoria spp.
l l
were present at Stations 1, 2, 3, 4, and 4A, where they have been recorded i
for the last several years, and were also seen at Station 15 in September.
Specimens examined for gonad analysis during August and September showed the shipworms to be primarily in the ripe and spawning stages where-as by October most gonads were in the spent condition. Many of the spent gonads were in young males that had probably set during the early-to-mid-summer months and became sexually mature.
I r
Histopathological observations revealed a heavy incidence of Minchinia infections in Teredo bartschi, especially at Station 7.
I I
I I
i I
I 1
I STUDY OF WOODBORER POPULATIONS IN RELATI0ff TO OYSTER CREEK GENERATING STATION by N. Maciolek-Blake, C.I. Belmore, and R.E. Hillman INTRODUCTION Battelle's New England Marine Research Laboratory is conducting I
an investigation to determine whether the generating station is affecting the resident marine borer population in Oyster Creek to the extent that that population is contributing significantly to marine borer-caused damage in Barnegat Bay.
A description of the program and procedures used may be found in the Fifth Annual Report titled Study of Woodborer Populations in Rela-tion to the Oyster Creek Generating Station, Report 15040, dated February 27, 1981.
This report presents data for the twenty-sixth quarterly period from August 22 to November 20, 1981.
PROCEDURES AND INTERIM DATA Exposure Panels The long-term and short-tern exposure panels were retrieved and replaced with new untreated pre-soaked (for two weeks) panels at the 20 I
exposure sites in Barnegat Bay and adjacent waters (Figure 1) during the periods September 9-10, October 6-7, and November 3-4, 1981.
Long-term and short-term panels at all stations werc retrieved and replaced with two exceptions.
At Station 13, the entire rack of panels was missing in Octo-ber,1981, and a new rack was installed the following month on November 3, 1981.
At Station 16, the owner of the Berkely Yacht Basin requested I
that we remove the rack from that location in November,1981. Although we were able to retrieve the November panels, we were not able immediately to locate a new site for the rack.
Table i describes the geographical locations of the exposure sites. The data for the laboratory examination of the panels may be found i
in Tables 2 through 5.
_-_----------d
4 t
ItA!ASQUAN i
l d%3 ngigttr POINT j
INTRACOASTAL s
UATTR1:AY CANAL MANTOL01:ING I
L i
C"'EEE
!I I
t S
N L
o j
l 8
l SEASIDE ATLANTIC M
j g 30 OCE!Ji
}
SLCOP i
CREEK I?0LLY l' ARK k l
l h
9 12 STOUTS CREEK I
SEDOE t; 3 8 ISLs;D (37 i,
f#
o.h V OYSTER b REEK OTSTER CREEK b-h6 BAPl;ECAT I!!LET i
t;UCLU.R GE: EPaTI::C STATION (J
VARETO:..'; V G
CITY BAPJ:ECAT EEACll 3'
I O PANE!, /.RPaY CO:.
I
}h ISLA!!D O
1 2
}!!ILES EA' NEGAT INLET, tiEU JERSEY
[
I Latitule 39* 45.8 I E
Loagitude 74* 06.0 W
[
2h # /
FIGURE 1.
OUTLINE OF BARNEGAT BAY SI:0*. JING CEOGRAPl{ICAL LOCATIONS OF I
EXPOSURE P/J ELS
-,-w w -ps-n n -v.e-~-w w-e,-v-w
--e,--.-
M M
M M
M M
M M
M M
TABLE 1.
GEOGRAPHICAL LOCATIONS OF BATTELLE NEW ENGLAND MARINF. RESEARCll LABORATORY'S EXPOSURE PANEL ARRAYS IN BARNEGAT BAY, NEU JERSEY Structure to be used for Nearest Previous Approximate Latitude Site No.
Site Suspension of Rack Data Stations and Longitude 1.
Barnegat Coast Guard Finger Pier WC 1 Lat. 39 45.8'N Station, Barnegat Inlet WFCL 1948-1967 Long. 74* 06.5'W 2.
Ashton Marina Bulkhead WC 13,14 Lat. 39' 40'N
?450 Bay Ave.
Long. 74* 13'W Manahawkin 3.
Iggie's Marina Bulkhead WC 16,17,18,19 Lat. 39* 45'N Long. 74* 12.5'W East Bay Ave.
Barnegat (Conklin Island) 4.
Liberty Harbor Marina Bulkhead WC 21 Lat. 39' 47'N Washington Ave.
R. Turner Long. 74* 11'W Warctown Rutgers U.
4-A*.
Holiday Harbor Marina Bulkhead WC 21 Lat. 39' 48'N
~
Lighthouse Drive R. Turner Long. 74* ll'N Warctown Rutgers U.
5.
Mouth of Oyster Creek, Dock WC 29,30 Lat. 39* 48.5'N Lot 4, Compass Road Rutgers U.
Long. 74* 10.3'W Offshore End 6.
Oyster Creek #1 Dock Lat. 39* 48.5'N Lagoon, Inshore End Long. 74* 10.35'W 37 Capstan Drive 7.
Private Dock End of Dock WC 27,28 Lat. 39' 48.5'N Dock Ave.
R. Turner Long. 74* 11.l'W Oyster Crcek Rutgers U.
Sands Pt. Harbor Wa*retown
l M
M M
M M
M M
M M
l t
i TABLE 1.
(continued)
Structure to be used for Nearest Previous Approximate Latitude Site No.
Site Stspension of Rack Data Stations and Longitude 8.
Oyster Creek-R.R.
Cross Member UC 26 Lat. 39' 48.7'N Bridge Bridge Rutgers U.
Long. 74* 12'W Discharge Canal 9.
Forked River Cross Nember WC 31 Lat 39* 49.2'N South Branch R.R. Bridge Rutgers U.
Long. 74* 12.2'W Intake Canal 10.
Teds Marina Pier WC 33,34 Lat. 39* 50.l'N Bay Ave.
Long. 74* ll.6'W Forked River
}
10A*.
Private Dock Under Dock Lat. 39* 49'N j
1217 Aquarius Ct.
Long. 74* 10'W j
Forked River A
10B*.
Private Dock Under Dock Lat. 39' 49.4'N 1307 Beach Blvd.
Long. 74* 10.1'W Forked River 11.
Forked River Bulkhead WC 35 Lat. 39* 49.7'N l
(near mouth)
Rutgers U.
Long. 74* 10'W il 1413 River View Drive e
i 12.
Stouts Creek Bulkhead WC 38,40,41 Lat 39" 50.5'N i
}
1273 Capstan Drive R. Turner Long. 74* 08.8'W l
Wurtz j
Rutgers U.
l 13.
Rocknak's Yacht Basin End of Pier UC 46 Lat. 39' 52'N
)
Scaview Ave.
Long. 74* 09'W
[
j Lanoka Harbor i
]
Cedar Creek i
i 1
i I
~ - - - - - _. - -.
i M
M M
M M
M M
M M
M M
M M
j:
TABLE 1.
(continued) l Structure to be used for Nearest Previous Approximate Latitude I
i Site No.
Site Suspension of Rack Data Stations and Longitude i
14.
Dicks Landing Pier WC 49 Lat. 39* 54'W l
I Island Drive R. Turner Long. 74* 08.1'W Bayville (Holly Park)
Nelson 1
15.
Winter Yacht Basin Inc.
Pier WC 57 Lat. 40" 02.5'N
{
Rt. 528 Long. 74* 03.5'W j
Mantoloking Bridge j
W. Mantoloking 16.
Berkely Yacht Basin Pier WC 60,61 Lat. 39* 55.9'N i
J. Street Long. 74* 04.9'W l
Seaside I
17.
Island Beach Pier WC 68 Lat. 39*47.l'If l
State Park L ng. 74, 05.9 W i
(Sedge Island) i All exposure panel racks suspended in a minimum water depth at mean low water of at least three feet.
Racks hung j
with nylon line from existing structures so the bottom panels are close to, but not touching the bottom.
Racks at
}
Forked River railroad bridge and Oyster Creek railroad bridge suspended with wire rope.
I WC = Woodward-Clyde UFCL = William F. Clapp Laboratories l
ASite 4-A installed April, 1977 Sites 10 A, 10 B installed April, 1978.
i k
I a
I l
~
M M
M M
M M
M M
M M
TABLE 2.
INCIDENCE OF TEREDINIDAE IN PANELS REMOVED SEPTEf1BER 9-10,1981 i
No. of Percent Size Range i
Site Panel Specimens Filled in mm.
Species Identification Remarks 1
P 800 98 5-35 800 T. navalis Ripe gonads and larvae j
C 1250 75 6-30 1250 T. navalia Ripe gonads and larvae 5
P 0
C 6
<1
<l-11 2 T. bartachi, 1 Toredo spp.,
}
3 Teredinidae*
l 7
P 450 35
<l-45 130 T. bartschi, Ripe gonads and larvae l
320 Teredinidae*
C 212 1
<l-7 2 T. bartschi, 210 Teredinidae*
8 P
1
<1
<1 1 Teredinidae*
C 0
m 9
P 1
<l 2
1 Teredinidae*
C 0
10 P
1
<1 34 1 B.gouldi C
0 10A P
3 7
105-150 3 B.gouldi C
0 l
11 P
11 17 45-135 4 B.gouldi,5 T.navalis, 2 T. navalic, 2 Teredinidae 2 Teredinidae**
dead C
1
<1 1
1 Teredinidae*
13 P
3
/
93-160 3 B.gouldi C
0 i
i l
1.
}
I f
TABLE 2.
(continued) l No. of Percent Size Range
,1 Site Panel Specimens Filled in nm.
Species Identification Remarks 14 P
14 20 1-205 9 B.gouldi,4 T.navalis, 1 Teredinidae*
C 1
<l 1
1 Teredinidae*
15 P
3
<1
<l-12 1 T.navalis, 1 Tercdo spp.
I 1 Teredinidae*
i l
C 0
i 17 P
2
<1
<1 2 Teredinidae*
l C
0 Sites 2-4A, 6, 10B, 12 and 16:
no Teredinidae present y
i P=
Long-term panel, submerged March 9-10, 1981.
C=
Short-term panel, submerged August 4-5, 1981.
- = Too small to speclate.
Damaged or missing pallets.
- =
1 i
l
!, p ' (p !;<
tad!.E 3.
If4CIDEf1CE OF TEREDIflIDAE 111 PAtlELS REM 0'!ED OCTOBER 6-7, 1981'
?
l i
fo'. of Pet cent Size'Ran9e Spe' i.nens F.lled in mm.
Species I.dentification Remarks Site Panel c
i 100 '.' nr>alis,
/1 P ~
800 99
<l-4b 700 Teredinidae*
<1% were alive j
/
f C
27 '
d
' ' < l-2 27 Teredinidae*
5 P
145 15
<l-295 1 B.gouldi, 9 T. b'artschi 5 T.'bartschi with 135 Teredinidae*
larvae
((/
/
'C 3'
<1 3 ieredi:adae*
6 P
1
<1
<1 1 Teredinidae*
C 0
7 P
1150 80
<l-150 2 B.gouldi, 130 T. bartschi, fiany T. bartschi ce 1028 Teredinidae*
with larvae C
48
<1
<1 48 Teredinidae*
8 P
1 2
140 1 T. navalis C
0 9
P 1
<1 54 1 T. navalis Dead C
0 10A P
1 4
220 1 B. gouZdi C
0 l
10B P
1
<l
<l 1 Teredinidae*
C 0
M M
M M
M TABLE 3.
(continued)
Ho. of Percent Size Range Site Panel Specimens Filled i n nm.
Species Identification Remarks 11 P
9 20 80-260 4 B.gouldi,5 T. navalis 3 T. nx alis dead C
0 12 P
2 5
105-144 2 B. gouldt C
0 l
14 P
12 35 38-260 8 B. gou7di, 3 T. navalis 1 Tamla s pp.
- C 0
15 P
1 2
100 1 B. goulds C
0 17 P
4
<1
<l-18 3 T. navalis,1 Teredinidae*
C 0
l l
Sites 2-4A, 10 and 16: no Teredinidae present.
Site 13, no panel recovered.
P = Long-term, submerged April 6-7, 1981.
C "- Short-term panel, submerged September 9-10, 1981.
- = Not speciated due to size or condition of pallets.
Ni
l M
M M
i TABLE 4.
INCIDENCE OF TEREDINIDAE IN PANELS REl10VED NOVEMBER 3-4, 1981 4
1
}
i i
Size Range i
Site Panel Specimens Filled in mm.
Species Identification
- Remark, 1
P 490 99 2-70 190 T. navalia, Only 14 live 300 Teredinidae*
l C
0 l
5 P
440 40
<l-80 90 T. bartachi, 350 Teredinidae*
l C
0 7
P 550 50
<l-45 250 T. bartschi, Umbonate larvae 300 Teredinidae*
present C
0 i
1 8
P 3
1
<l-52 2 T. navalis, 1 dead i
1 Teredinidae*
1 C
0 l
10A P
2 1
2-50 1 T. bartschi, 1 Teredo spp.*
c l
C 0
11 P
3 5
70-150 1 B. gouldi, 2 T. navalis C
0 12 P
2 6
92-183 2 B. gouldi C
0 l
14 P
6 3
<l-153 1 B. gouldi, 5 Teredinidae*
f C
0 15 P
1
<l 4
1 T. navalis 1 dead I
C 0
Sites 2-4A, 6, 9-10, 10B, 16 and 17:
no Teredinidae present.
New rack installed at Station 13 - no panels examined.
P = Long-term panel, submerged May 4-5, 1981.
C = Short-term panel, submerged October 6-7, 1981.
- = Not speciated due to size or condition of pallets.
R
TABLE 5.
INCIDENCE OF LINNORIA IN PANELS REMOVED SEPTEMBER, OCTOBER AND NOVEMBER, 1981 September October flovember No. of No. of No. of No. of No. of flo. of Site Panel Tunnels Specin: ens Tunnels Specimens Tunnels Specimens 1
1 P
220 170*
130 45*
32 3
C 13 5
7 4
0 l
2 P
380 340**
350 100*
178 63*
C 3
2 0
0 j
3 P
260 200**
200 200 0
l l
C 0
1 1
0 4
P 550 500**
720 720**
220 200**
3 C
2 2
0 0
4A P
6300 5800 6500 4500 7000 5000 C
320 200*
48 40 3
3 15 P
46 16 0
0 C
0 0
0 Sites 5-14, 16 and 17:
no Lim:oria present.
P = Long-term panel, submerged 6 months.
C = Short-term panel, submerged 1 month.
- = Juveniles present.
- = Gravid females and juveniles present.
12 Water Quality Salinity, water temperature, dissolved oxygen, and pH were determined with a Hydrolab (flodel II B), calibrated prior to each day's use.
The results for September, October and riovember,1981 may be found in Tables 6 through 8.
, l 1
Teredinid Gonadal Development Studies Table 9 shows the gonad condition of the teredinid borers col-lected in August, September and October, 1981.
Included are results from panels exposed for periods rangir.g from 6 to 12 months.
- I I
l f
l l
- - - ~ - -
M M
M M
M M
M M
M TABLE 6 WATER QUALITY AT EXPOSURE PANEL STATIONS SEPTEMBER 9-10, 1981 i
Depth in 02 Station Date Time Feet Salinity (o/qq)
Temp ( C)
( mg/l) pH 1
9/9/81 la50 3.0 32.3 22.8 7.1 7.9 2
9/9/81 1520 2.5 32.9 23.3 6.5 7.5 3
9/9/81 1550 2.5 30.7 23.6 7.1 7.5 I
4 9/9/81 1615 3.0 30.0 23.4 6.4 7.6 4A 9/9/81 1630 3.0 30.4 23.9 6.1 7.8 5
9/10/81 1030 2.5 28.9 22.3 6.6 7.7 l
6 9/10/81 1005 2.5 29.0 21.8 6.8 7.7 l
7 9/10/80 0950 3.0 29.5 21.3 6.4 7.7 l
8 9/9/81 1645 3.0 28.9 22.9 6.9 7.9 C
9 9/9/81 1700 3.0 29.6 23.2 6.9 7.9 10 9/9/81 1805 3.0 26.0 23.9 7.7 8.1 10A 9/9/81 1715 3.0 29.7 23.6 7.5 8.0 108 9/9/81 1740 3.0 29.7 23.5 7.6 8.1 11 9/9/81 1745 2.5 30.7 22.9 7.1 8.0 4
12 9/10/81 0930 3.0 28.1 21.3 5.5 7.3 13 9/9/81 1825 3.0 23.4 23.2 7.7 7.1 14 9/9/81 1900 3.0 28.3 22.3 6.6 7.8 l
15 9/10/81 1150 3.0 25.3 21.9 6.5 7.6 l
16 9/10/81 1215 3.0 23.5 21.9 7.0 7.7 17 9/10/81 1330 3.0 32.7 21.4 6.4 7.8 L
i l
M M
M M
M M
M M
M TABLE 7.
WATER QUALITY AT EXPOSURE PANEL STATI0f4S OCTOBER 6-7, 1981 i
=-
Depth in 02 Station Date Time Feet Salinity (g/co)
Temp ( C)
(mg/l)
PH 1
10/6/81 1900 3.5 34.2 17.3 7.1 7.7 2
10/6/81 1920 3.0 33.1 16.4 7.8 7.9 3
10/6/81 1810 3.0 31.5 17.4 7.9 7.8 4
10/6/81 1750 3.0 30.7 17.2 7.7 7.7 l
4A 10/6/81 1730 2.5 31.0 17.2 8.2 7.8 i
5 10/7/81 1100 3.0 29.3 15.2 7.6 7.7 6
10/7/81 1045 2.5 29.3 15.4 7.4 7.7 l
7 10/7/81 1030 2.5 29.2 14.7 7.2 7.7 l
8 10/6/81 1720 3.0 28.7 16.2 8.1 7.7 j
9 10/7/81 1120 2.0 30.1 14.7 7.7 7.9 l
10 10/7/81 0915 3.0
- 27. 2 15.2 7.0 7.7 10A 10/7/81 0930 2.5 30.1 15.1 7.1 7.5 i
l 10B 10/7/81 0940 3.0 30.3 15.1 7.3 7.7 11 10/7/81 0945 2.5 30.3 14.3 7.1 7.8 l
12 10/7/81 0905 3.0 28.8 15.1 7.7 7.7 l
13 10/7/81 0850 3.0 23.1 14.5 7.1 7.7 j
14 10/7/81 0840 2.5 27.3 14.4 7.6 7.6 15 10/7/81 1230 3.0 26.9 15.4 7.4 7.3 3
16 10/7/81 1245 3.0 23.1 1F 1 8.0 7.8
]
17 10/7/81 1310 2.0 33.3 19.3 7.7 7.7 l
I
M M
M M
M M
M M
M l
l l
TABLE 8.
WATER QUALITY AT EXPOSURE PANEL STATIONS NOVEMBER 3-4, 1981 Depth in 02 Station Date Time Feet Salinity (o/co)
Temp ( C)
(mg/1) pH 1
11/3/81 1710 3.0 31.5 12.8 8.9 7.5 2
11/3/81 1630 2.0 30.0 12.7 9.3 7.6 3
11/3/81 1615 2.0 31.0 13.1 9.3 7.4 4
11/3/81 1550 2.0 29.8 13.5 9.0 7.5 4A 11/3/81 1540 2.0 29.7 13.7 9.7 7.6 5
11/4/81 1040 2.0 25.1 16.0 8.1 7.4 6
11/4/81 1025 1.0 25.2 16.0 8.0 7.5 7
11/4/81 1010 1.0 24.7 16.5 7.9 7.3 8
11/3/81 1520 1.0 27.3 16.9 9.4 7.5 5
[
9 11/3/81 1450 2.0 28.3 13.0 9.2 7.6 l
l 10 11/3/81 1340 3.0 22.7 14.2 8.5 7.3 10A 11/3/81 1400 2.0 28.3 15.6 9.0 7.4 10B 11/3/81 1415 2.0 28.5 13.7 9.3 7.4 i
11 11/3/81 1425 2.0 28.6 13.8 10.0 7.5 I
12 11/3/81 1310 2.0 24.5 13.1 9.7 7.5 13 11/3/81 1255 3.0 26.0 13.5 S.8 7.4 14 11/3/81 1220 2.0 23.1 13.1 8.9 7.5 15 11/3/81 1140 2.0 24.2 12.9 9.5 7.5 16 11/4/81 1150 2.0 16.9 12.5 8.4 7.4 l
17 11/4/81 1250 1.0 27.7 15.5 8.8 7.6 1
i n
4
I 16 l
!ACLE 3.
CO?.JITIO!4 0F GONADS OF TEREDINID ECRERS RE"C'!ED FRO *i I
EXPOS'JRE PA?oELS IN CARNEGAT BAY FR0f t AUGUST THr0 UGH l
OCT0;ER. 1931 EA = Early active; LA = Late active; R = Ripe; PS = Partially spa'.med; 5 = Spent; If = Male; I
F = female; H = Hermaphrodite S pc ci:ren Month
?io. ilos.
Gonad
?:o.
St1ti?n 7e oved Exposed Species Se<
Ccnditien Coments 932 15 Aug 31 6
52si<2 jaO.
M R
Cyst in gill 933 13 Aug 31 1
52di
-1 No discernable gonad; I
very young 934 10A Aug 31 1
?rsia J aWi fio discernable gonad; very young I
935a 11 Aug 81 1
5:di: Jra R.
t.o discernable gonad; very young b
..:d i: ; a2 No discernable gonad; very young 936a 11 Aug 81 6
Ten nmha M S
- in,ici-b Tcrei; n :::i
- 1 5
'inni:::
c Tsrci; n;p:.
F PS ni:in;, unidentifie:
mass containing baso-philic gran;les be-I neath epitheliun d
Teni: eava..,
11 S
!in' s i:
e Te re '- a::::i M
S
'in: ini:
9372 12 Aug 81 6
F:dh ;aMi No discernable gonad b
had #c ;. 2 :
M EA c
5:n
_2 JaL:
il LA 933a 14 Aug 81 5 m.: ;ra;.is No discernabla gonad; very young b
5:d _ paMi No discernable gonad; very young c
8 v:kia ;; L No discernable gonad; very young I
983a 14 Aug 81 6
Tcrei,c:enis :t PS b
Tercia nava:is M LA Gill lamellar hyper-plasia C
Tercio nar2;ia M LA Some leukocytosis under rr.antle epithelium 930a 7
Aug 81 er.:13 l wis A s No discernable gonad; developing 1;rvae in broo" puuch; 'ie:S:{.-
b Tercia Lw!a:
No discernible gondd; deselooing larvae in arood pouch; spectren necrotic; roribund
'.> ~ inia i
c Terc= t w::,
H S
'in. int, 931 12 Aug 31 1
zud:2 ;ca Mi M
EA 992a 7
Aug C1 12 Wr-la b misi:i H S
Special panel; larvae in brood poJch; necro-tic,probably dead.her fixed b
Terci; i wN 'u 40 discernable gonad; larvae in trood pouch; I
necrotic; probably dead wnen fixed C
Tercia L w :n t H S
Larvae in brood poucn; necrotic; probably dead when fixed 993 103 Aug 31 6
nidi 2 : Ja Wi M
l TABLE 9.
(continued) n.
Spectren ibntn fio. !'o s.
Gonad No.
Statien P rove _4 Eyesed Species Sex condition Covents 9Na 1
Aug S1 6
Terch na 2?is H
EA b
"cr.1 ?> na : :
M EA c
Terch n29;?ia in she.?rnable 50nad d
Tarcia naa :ia tio itn o nable ganad; necrocic e
Tarela rav:tia M
EA f
Tercia nas:.is M
!.ecrotic digestive tubules 9
Terch nara!ia fo discernable gonad h
Terch n::ali3 F
EA i
Tercio r.a n :fa M
EA J
Terch v.avalia H
EA I
k Terch r.an.ta H
EA 1
Tcreh r u zlia M
.m
'erma na n lia f0 discerm ble gonad n
Tcccaa n::2:is M
EA 935 11 Aug 01 12 3r via ; a;a:.
M R
Special panel 976a 1
Aug 31 1
Terc h n s;:ia M
EA b
Tereia n:J:u 11 S
c Terch nanlis F
EA I
d Tereda r valia F
EA e
Terch r.::alla M
LA f
Tercia nan.is F
CA g
Terch r.:v:lia F
EA I
h Tercia r.ava.is F
EA i
Terch r.:nlia M
EA fiecrotic lesions in digestive gland j
Teret n:ca!ia EA Gills necrotic; some hypertrephy of addJctor muscle 937a 103 Sept 81 6
B:n;ia walli fio discernable gonad b
Bar.kia jou:aa M
S c
2:nkia pull:
M S
9334 13 Sept al 6
3:nkia p a?if M
S b
Bar.kia pauli:.
ti PS Cyst in mantle from relatively large metazoan c
Eankia paldi M
PS 933a S
Sept 81 6
Tereh bar:achi H
PS b
Terch bartachi H
PS I
1000 15 Sept 81 6
Terch nau Zis M
S 1001a 11 Sept 81 6
Bankia gealii M
S b
Banki: gou'.li M
S C
B&ia pui.i M
S I
d Szukia jca!Ji M
PS 1002a 1
Sept 81 Tereb nasalia l
R b
Terch navalia F
R Early larvae in brood pouch c
Terch n:Jalia M
PS d
Tccedo n:nfi fio discernable gonad; early larvac in brood pouch e
Tcre is n:Ja L L t1 S
I f
TereJa n20i:ia F
R g
Teredo n az;ta F
PS h
Terc > n.ca1:ta F
PS i
Tere.!a c:nlia F
PS Early larvae in brood I
pouch j
Tcre!a r.a alia F
PS Early Idryae in brood J
pouch k
Tcrad> n,:ntia H
PS
I 18 TfdLE 9.
(continued)
Speci en
- lanth Na. Mos.
Gonad No.
Station Rem ed E qosed Species Sex Conditien Covents I
1C03 10 Sept 81 6
Jadia;caldi M PS 10013 11 Sept 31 6
Tere,6 3ax u M S
b
- erch, v::lJ ;1 5
'in e h
c Tcrah ravilia M S
- !in -...
1005a 1
Sept 31 6
r.ral, nr ia F PS b
Terch ru utis F PS Early.'irJ>;
Ma plasmodia c
Tercle rava:u F FS Early..>.:
plasnodia d
Terci) 'uV:lir F S
' inn i5.- plas'odia e
rece b nau::Is M PS
. i plas adia I
f Tcych c;:!ia F PS Early
'>3*-
plasradia g
F PS 10:6a 12 Sept 31 12 JunL 2 ;2.
Special canel; no dis-cernacle g:nad; ne,o-cytic infill:ratic, into several tissues b
5:di:, c. :
!;o discccc.aole gonad 1007a 14 Seat 81 6
Tce:A,ue :
F S
I b
Tere:J rav=:ia M S
c Terel: n ::wia M S
d Tercio n=. 'a F
S IC00a 7
Sept 81 Tereb bar:s:.H S
Early.
-a b
Tereir :rea.
No discernacle gonad; sfi,: -
c Tercia ::r o:M H S
"b::. ia d
- sr.:b t w:s3.F PS Early. in:
I e
- crei, L ar:::hi H S
f Ter,:h ! w:::hi H S
's s i> :
9 Tarab b:rtaa :. H S
Hus.
h Tcr.-E b.;r t.'an No discerna::le gonad; larvae in br:cd panel
!!in ='n::
1 Terc'
'~r's hi H S
itiny ? :
j Terela br:schi No discerr.able gonad; s 'in:.> ::
I k
crch bartashi H S
Tarch b:rta:.
?:inrhini:
1 Tereb Hr
,hi H S
!!ir. :. inia m
Terei> bartes i H PS Occasional
'ir ed n i.
plasnodia; cardiac in-flamation n
Terch bartsni H PS Minchi,::
1009a 7
Sept al 12 Tercia :mw:c.hi !!
PS Npr-tal panal; early plasmodia I
b Tcreb ! ; 'c *.
No discerr. M e ganad; larvae in brocd pauch c
Tera b b :r ca,.
No discernable gonad; l?rvae in tre;d pcucn
'i n-in:1 d
Ter.:.io c :r t. se H S
'inAini ~
e Ter:h h ir:n H
S
!!!r.Ai, a f
Terch i.ar :hi H S
isin.
!i a
I g
Tcech. :renhi H S
Larvae in brood pouch;
- t;,
h Tcec h !ze: :h' No discern 1ble g0nad; larvae in brood pouch.
"in h i> -
i Teredo :.arta:hi H S
" s.. > :,. 2 j
Tereda Lar cac No discernable gonad;
,"ina b.i:
?
}
I 19 TACLE 9.
(continued)
Speci en Month No. Ikas.
G nad
- 0.
Station Pemoved ES ased 5;ecies Sex Ccnditica Ce ments 10223 1
cc t 31 6
lm : > :ra.
M S
b Tcw ~ c::
M PS c
o ral; *. is No discern 3ble gonM; I
" r.:hin i ;
I d
".ral; > c:a ia F
S r
e
- ,: n :2.is M
S
- !i < Dn :
f
- cec L~ vra.
M S
Necrotic;
~ ini:
I r2 ifs tio discern 5ble gonad; g
- crca:
necrotic; ':t 6.i.:
1023a 7
Oct 81 6
% b barte: -
H PS
?in '.fi:?
b Teree. eu No discernacle gonad; "i r. : ini:
C
- e r:.12 I r*
H
!b: n.
52 F
5
- f r :
d c
-,2
~.
e Terc cric.hi f.o discern 3ble ganad; o.a f
- er-L ::2. ~.
H g
-c
^22 No discernable gona1; larvae in br: d p:u:*
h Tered; c2rt.-
No discernable gonsc;
. :. n e. >..
i Tcre b : r s fio discernable gon3d;
'in. :
~
j
'creb b:rt.,
No discernable gon31;
!inrhini:
k
- cre : : :r t.
H S
'i>::h i>:i:
1
%u : : r:a:.
H S
r.
n Tere > :;;r:c t
F S
n revi> L=r:::n.
H PS o
Teu :. c :r t.
h i H
S Larvae in broad p wcn; ti.:
102 4 7
Oct 81 6
Fan:: 2 y:4..
No discernacle gonad b
3:nk:.: ;:ula:
M S
1025a 7
Oct 81 12 Terc h ;r:ss:.
H S
Special parel; b
lcr ia :rt.
H S
lEn:hini:
C Tcrai cir:::hi H
S l!ir:hirla d
Tereb b r: rhi H
S "b:s:ini:
e creia cr:: hi H
S "s::.;ini 2 plas~odia f
Tere 3 bar:w H
S 9
- era b b:r:: n H
S
- !!n: ini: plasrodia n
Terci: b2rta:hi H
S
. Vin ~ b:i 2 i
Terc<!a c:r:ss.
No discernable gor.ad;
- >s. inia j
Terci> i r:Jm No discernable 90 rad; larvae in trood m uch
!!in ? - ia k
"ecch wic.rhi H
PS
'in D:ia I
1 Terc.,
- hi H
S
>.> ia m
Tar, !;
- w.
H u fini; n
Ter:!= ' :r::: 1.
H S
... b. :. ;
o 7,:rc.u zein.
H PS
!b..hb:ia 1026 11 Oct 81 12 SvG
.o J 3 Special panel; no dis-cernable ';on3d; cyst in rantle 1027 17 Oct 81 12 l cec h n n :La Special panel; no dis-I cernable gonad 1023a 17 0'.t 01 6
- cre !a n o d.
No discernable gcnad; noribund., shi..
plasmcdia I
b Ter.,,:..:'la No discernable gonad c
- ce.- D n n:. ia No discernable gonid I
I l
l TASLE 9.
(continued)
Specimen Manth No. Mas.
Gonad I
No.
Station 2e mved Exposed Species Sex Candition Cetrets 1010a 14 Sept 31 6
fud : valds No discernable gor.ad b
Ba di1 p 1:li M
S l
c B:di2 a:uh M
S d
Pr:kia par:
M S
e aadia y ah No discernable gccad f
Pedia p.J.:.
M EA Cysts g
32ki-z. aldi M
EA l
h 3:dia 3:u'di M
S i
Badia g:sh:.
M S
1011 10A Oct 31 6
3:nkia p idi M
EA 1012 15 Oct 31 6
52v:ia cra:di No discernable gcr.ad; I
focal herocytosis; gra'1ulocytc s 1013a 12 Oct 31 6
Fad u Trardf M
S b
5:df2 pa:A M
S l
(
10143 14 Cct 81 6
am?:a jeu 2:.
M S
Necrotic b
Badia, c.di; M
S hecretic c
Exk. pal.
M S
Necro tic d
32C ia ;:u:di No discernnble gcnad; necrotic l
e
??kia pud:.
M S
i f
Sankia p a'!?
M S
Cyst; necrotic diges.
tive tubules g
Bad u p uidi M
S Necrotic h
S:-kia pa b r.
No discerr3ble gcnad; necrotic 1015a S
Oct 81 6
Tcre..> b2r:aan.
H S
' > - inu b
Tercia b 2r::_>hi H
S
,.r.. tinia c
Ter?h bar:a:h:.
H S
Early 'in :. i:
i plasmedia
\\
d Terch cart.ran.
F S
ni v :nia e
Tercia b:rtachi H
S A few early. 'ichind; plasmodia f
Tercia b rtachi H
S Early.'in:hinia l
plasrodia g
Terr-13 barta3hi No discernable gonad; larvae in brood poact r
l
. !!>uhi>. t.:
h Tercdo b rta32; H
S Early. 'id: inia plasmaata 1016 S
Oct al 6
Sadia puIds No discernable gona.1; i
cysts; hemocytosis 1017a 14 Oct 81 6
Terch nr2?is F
S i
o Terch navalia F
S l
c Tercia c:v2tfJ F
Focal henocytosis I
1013 14 Oct 31 6
Terab mua!_ '
M S
101h 11 Oct 81 6
5:dia :a?d h
S Pemocytosis b
fadia ; calli M
S Hecccytosis; granulo-cytoma l
C Eadia pulil M
S d
Sr.
pali?
H S
Cysts; focal hemo-i cytosis 1020a 11 Oct 31 6
'"ccc h >uralia M
S
'whi, c : plasmodia I
b
-c r. -.?a,.. :,.
F S
>>7 1021 8
Oct 81 6
Tereb na>a Ua M
S "f e,
> Ca
I l
I
(
a i
ne l
Battelle l
New England i
Marine Research Laboratory 397 Washington Street Duxbury, Massac husetts 02332 I
Telephone (617) 934-5682 I
I I
l I
1 I
. ~
-