$04) o s~

DEC 161981 General Electric Company

' ATTN: Mr. J. A. Long, General Manager

-Wilmington Manufacturing Department P. O. Box 780 Wilmington, NC 28402-Gentlemen:

Subject:

Report No. 70-1113/81-15 This refers to the routine safety inspection conducted by Mr. L. A. Franklin of this office on November 16, 1981 and November 20, 1981, of activities authorize'd by NRC License No. 1097 for the Wilmington Manufacturing Department facility and to the discussion of our_ findings held with Mr. W. J..Hendry at the conclusion of-the inspection.

I-Areas examined during the' inspection and our. findings are discussed in the enclosed inspection report.

Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector.

Within the scope of this inspection, no violations or deviations were disclosed.

We have examined actions you have taken with regard to previously identified enforcement matters and unresolved items. The status of -these items is discussed in the enclosed report.

In accordance with 10 CFR 2.790(a), a copy 'of this letter and the enclosure will-bc 91 aced in the NRC's Public Document Room unless you notify this office, _by telephone, within ten days of the date of this letter and submit written application to withhold information contained therein within thirty days of the date of this letter. Such application must be consistent with the requirements of 2.790(b)(1).

Should you have any questions concerning this-letter, we will be glad to discuss them with you.

Sincerely, M/

A. F. Gibson, Chief Technical Inspection Branch Engineering and 'echnical Division Enclosure (See Page 2) 9112310257 811221' hDRADOCK 07001113 l

PDR; l

DEC 161881 General Electric Company 2

Enclosure:

Inspection Report No. 70-1113/S1-15 cc w/ encl:

C. M. Vaughan, Manager Licensing and Compliance Audits bcc w/ encl:

Document Management Branch State of North Carolina bcc w/o encl:

License Fee Management Branch RII RII RII RII g

Chose {yl! $,Q ct R Ghth LFran,kl in : e s AGibson 12/gi/81 12/H/81 127F/81 124b /81