DEC 7 1931 Docket Hos: 50-369 and 50-370 i
LICENSEE:
DUKE POWER COMPANY j
FACILITY:
McGuire Huclear Station, Units 1 and 2
SUBJECT:
SUMMRY OF HEETING HELD ON NOVEMBER 20, 1981 i
j A meeting was held with the licensee on Noverber 20, 1981, to discuss preheater-
]
type stean generator tube problems in foreign reactors as ralated to the operation of McGuire Unit No.1.
A list of attendees is shown on Enclosure 1.
The major briefing presentation was nade by Westinghouse and included the results to date of testing of the Model D steam generator at two foreign reactors. These steam generators are of sinilar design (Model D) to those in the McGuire Unit 1 pl a nt.
Eddy Current testing has revealed that there are indications in the outer rows of tubes in essentially all steam generators so tested. Westinghouse has l
initiated a program of testing and tube examination along with analytical evalu-ations to determine the initiator of this tube degradation phenomena. Westinghouse believes at this time that tube degradation can be attributed to excitation of the tubes from high fluid velocities and/or non-uniforn velocity distribution.
I The licensee stated that McGuire Unit I was shut &.n on November 16, 1981 and that j
an operating plan for Unit 1 had been developed (see Enclosure 2). Rows 47, 48 and 49 in "A" Steam Generator (S/G) were Eddy Current tested. The results were negative J
with possibly one sif ht indication. The licensee has installed external vibration 9
nonitors (3 transducers per S/G) on each S/G. Upon completion of this inspection effort, the unit will be restarted and a power level of 75% established, approx.
Hovember 23. Upon completion of the traditional 75% plateau power ascension testing
( 2 weeks), the unit will be shutdown and S/G Eddy Current testing repeated on S/G "A".
During unit operation, nonitor instrumentation will be evaluated.
Interim operation on the above basis appears appropriate at this time.
t The licensee indicated that further operation at 90% power is contenplated to con-plete some ascension testing ( 1 week) provided no indications above 20% are dis-4 i
covered in S/G "A".
Following this week of testing, evaluation of the monitoring, and evaluation of 50-90% power data, they wculd decide on escalation to 100% power for one day. Data evaluaticn at this time would determine whether or not the licensee would plan to continue operation at an acceptable power level or shut down at that tine for further EC testing.
l 1
i l
l l
omccp........... 8112300206 811207 suRucus>
PDR ADOCK 05000369.....
................)
P pgg om>................l............;..................
NRC FORM 318 (10-80) NRCM 024o OFFICIAL RECORD COPY usam isu-mem i
. Since the information presented by liestinghouse was proprietary, the licensee agreed to document the information pursuant to 10 CFR 2.790.
4 L
Ralph A. Birkel. Project Manager
~
Licensing Branch Ho. 4 e,
Division of Licensing
Enclosures:
1.
Attendance List 2.
McGuire Nuclear Station.
Unit 1. Operating Plan i
4 I
I" vp>
n 0FFICE)....O L, L 6..M 4......LA:0L;LQ..#4......E ll *
..d 4..
l suauwe >,....Bil.kkst.1/.hac..@.u n c a.n.,,,,,,,
,,,,,,E
,,, g,s am,,
l om>... 12 /.).. / 81.....12/.J./81........... 12 /..M./.81..
i..................
- NRC FORM 318 00-80) NRCM 0240 OFFICIAL RECORD COPY usomen-m so
1 l
,,4 '
McGuire
\\
Mr. William O. Parker. Jr.
Vice President - Steam Production Duke Power Company P.O. Box 2178 l
422 South Church Street l
Charlotte. North Carolina 28242 cc: Mr. W. L. Porter Shelley Blum. Esq.
Mr. A. Carr 1716 Scales Street Duke Power Conpany Raleigh. North Carolina 27608 P.O. Box 2178 422 South Church Street Mr. Paul Bemis Charlotte North Carolina 28242 Resident Inspector c/o U.S. Nuclear Regulatory Commission Mr. R. S. Howard P.O. Box 216 Power Systems Division Cornelius. North Carolina 28013 Westinghouse Electric Corp.
P.O. Box 355 Pittsburgh, Pennsylvania 15230
~
Mr. E. J. Keith EDS Nuclear Incorporated 220 Montgomery Street
. 2--
San Francisco. California 94104 Mr. J. E. Houghtaling NUS Corporation 2536 Countryside Boulevard Clearwater. Florida 33515 Mr. Jesse L. Riley. President The Carolina Environmental Study Group 854 Henley Place Charlotte. North Carolina 28207 J. Michael McGarry. III. Esq.
DeBevoise & Liberman 1200 Seventeenth Street. N.W.
Washington. D. C.
20036 Ms. M. J. Graham Resident Inspector McGuire NPS c/o U.S. Nuclear Regulatory Commission P.O. Box 216 Cornelius. North Carolina 28031 e
e
4 4
i i
I ATTEn0ANCE LIST l
ItcGuire fJuclear Station, Units 1 and 2 hovember 20, 1981 L
DUKE POWER C0ttPANY i
Skip Copp 4
- 11. B. Tucker C. W. llendrix. Jr.
A. L. Suddoth j.
WESTINGHOUSE CORP.
H. J. Connors I. C. Ratsep l.,
M. A. Weaver N. P. Mueller B.ft. Bownan Antonio Aldeanueva
- 0. J. Woodruff i
K. L. Ituffman T. F. Timons i
Deryk R. Grain NRC STAFF Ralph A. Birkel Willian V. Johnston Philip itatthews Victor Benaroya Conrad McCracken E. G. Adensam i
K. N. Jabbour C. Y. Cheng W. J. Collins J. Rayan T. J. Kenyon R. L. Tedesco Nick Economos Alan Herdt i
P.h Wichman j
2auts Crutchfield Emett Murphy l
E. Igne i
_0THERS i
Jose I. V111adoniga -
Consejo De Seguridad Nuclear - Spain Julian - Gorosarri -
i Alanaraz Power Plant t
.-,,m
.....E4Tt Eri :,1,1,a,n,9,v,gy,,, :,,C.,,N,.,A1.Ep, rag.
I Proje,c t
- omce, son -
sun
.e >
..........m.m,..m.yg.. sci ence ofrtcu--
- anep
.. ~.. -... -..
- -. - ~ ~... -
...~.-~~~
~~~~ ~~~~.
.~~... ~...~.
]
panc roam 318 00-80) NRCM 0240 OFFICIAL RECORD COPY usam mmm l.
---e
,-~4
--v--.--
w-1-*'r--*e
==v i--~w v=*"**e+mrerdwv
- F""*'"N"-*"
i ItGUIRE f0 CLEAR STATION - UNIT 1 OPERATIf6 PLAN o C0f00CT EC ENilfMTION "A" S/G R0WS49,48,47,I
~
o INSTALL EXTERfML INSTRliMATION "A" S/G o EVAUJATE EC EX#1IfMTION RESULTS IF INDICATIONS <20% CQlTINUE OPERATION IF INDICATI0f6 >20%, INSPECT 4 S/G, EVAUMTE o ESCALATE TO 75% POWER, CUPLETE TESTS, (~2 WEEKS)
- MONITOR INSELIMATION, EVAUMTE o SHUTDOWN - CONDUCT EC EX#11tMTION "A" S/G R0WS49,48,47,5 o EVALlnTE EC EXM11tMTION RESULTS IF INDICATIONS <20% C0flTINUE OPEPATION IF INDICATIONS >20%, IfSPECT 4 S/G, EVAUMTE k
Q,.. <. -
MC GUIRE NUCLEAR STATION - UNIT 1 OPERATING PLAM o ESCALATE TO 90%, CORETE TESTS (lWEB0 o MONITOR INSTRLMWTATION, EVAUJATE o EVAUJATE 2-90% POWER DATA
- IF SATISFACTORY, CONTINUE ORRATION
- IF UNSATISFACTORY, ORRATE AT REDUCED POWER o ESCALATE POWER TO LOO % (mXIM11 DAY) o AT THIS POINT EITHER:
- 1) gE}Tgg]3E POWER LEVEL BASED ON DATA
) k)bdAfN!hRLb WHILESHLflDCWN o
ECT INSRCTION 4 S/G INSTALLINTERNALINSTRUWNTATION2 TUBES,1S/G EVALUATE 50 - 100% POWER OPERATION PLUS OTHER DATA o DETERMINE APPROPRIATE NEAR TERM OPERATING CONDITIONS f
USE OF CT EINED MAIN, AUXILIARY FEED N0ZZLES POWER LEVEL o RETURN To POWER 1
O e
6
MEETING
SUMMARY
DISTRIBUTION Docket File %T 36 9 G. Lear NRC/PDR S. Pawlicki local PDR V. Benaroya TIC /NSIC/ TERA Z. Rosztoczy LB #4 r/f W. Haass H. Denton D. Muller DEC 7 1S81 E. Case R. Ballard D. Eisenhut W. Regan R. Purple R. Mattson B. J. Youngblood P. Check A. Schwencer
- 0. Parr F. Miraglia F. Rosa J. Miller W. Butler G. Lainas W. Kreger R. Yollmer R. Houston J. P. Knight W. Gammill R. Bosnak L. Rubenstein F. Schauer T. Speis
' Til l' n R. E, Jackson W. Johnston Attorney, OELD S. Hanauer 8
[f[ }/'[/,
/
OIE (3)
T. Murley
//
ACRS (16)
F. Schroeder S-OEC 7 g IS R. Tedesco D. Skovholt Z
N. Hughes M. Ernst
. v.,,blUg[;*-[J/-.
K. Kniel NRC
Participants:
G. Knighton A. Thadani G
R. A. Birkel D. Tondi
/ 46','ii W. V. Johnston J. Kramer P. Matthews D. Vassallo V. Benaroya P. Collins C. McCracken D. Ziemann E. G. Adensam F. Congel K. N. Jabbour J. Stolz M. Srinivasan ns R. Baer J. Rayan T. J. Kenyon C. Berlinger E. Adensam R. L. Tedesco N. Economos Project Manager R. A. Birkel A. Herdt Licensing Assistant M. Duncan K. Wichman i
D. Crutchfield E. Murphy E. Igne bcc: Applicant & Service List i
---