APPENDIX A NAMC0 Controls Division Acme-Cleveland Corp.
Docket No. 99900378/81-01 NOTICE OF VIOLATION As a result of the inspection conducted on October 12-16, 1981, and in accordance with the Interim Enforcement Policy, 45 FR 66754 (October 7,1980),
the following violations were identified:
A.
Paragraph 21.6 of 10 CFR Part 21, states in part, "Each individual part-nership, corporation or other entity subject to the regulations in this part, shall post current copies of the following documents in a conspic-uous position on any premises, within the United States where the activities subject to this part are conducted: (1) the regulations in this part; (2) Section 206 of the Energy Reorganizaticn Act of 1974; and (3) procedurts adopted pursuant to the regulations in this part."
Contrary to the above, current copies of.10 CFR Part 21 had not been-posted. The posted copies were identified as: Federal Register, Volume 42, No.108, dated June 6,1977.
This is a Severity Level VI violation (Supplement II).
B.
Paragraph 21.21(a) of Title 10, Part 21, of the Code of Federal Regula-tions, states in part, "Each individual, corporation, partnership, or other entity subject to the regulations in this part shall adopt appro-priate procedures to: (1) provide for, (i) evaluating deviations, or (ii) informing the licensee or purchaser of the deviation to be evaluated... and (2) assure that a director or responsible officer it inforced if the... basic component supplied... (i) fails to comply... relating to a substantial safety hazard, or (ii) contains a defect."
Contrary to the above, procedures had not been adopted to provide for:
(1) evaluating deviations or informing the licensee or purchaser; and (2) assuring that a director or responsible cfficer was informed if the supplied basic component (a) failed to comply or (b) contained a defect.
This is a Severity Level VI. violation (Supplement II).