UNITED STATES
., hg
,,g NUCLEAR REGULATORY COMMsSSION i
a$N j
WASHINGTON. D. C. 20f M
-b,/
~
2 PORTLAND GENERAL ELECTRIC COMPANY THE CITY OF EUGENE, OREGON
~ "~~ ~
PACIFIC POWER AND LIGHTICCMPA'NY -
u.
u.
DOCKET NO. 50-344 TROJAN NUCLEAR PLANT.
~
AMENDMENT TO FACILITY OPERATING LICENSE
~~
Araendment NOT 69 License No. NPF-1 1.
The Nuclear Regulatory Comission (the Comission) has found that:
A.
The application for amendment by Portland General. Electric Conpeny, the City of Yugene, Oregon, and; Pacific Power and Light Company w.,
(the licensee) dated October 8, l'981 complies with the standards and requirement; of the Atomic Energy Act of 1954, as amended (the Act) and th'e Commission's rules and regulations set forth
~
in 10 CFR Chapter I;
'B.
The facility will' cperate in conformity with the application,
- the provisions of the Act, and the rules and regulations of the Comission; C.
There is reasonable assurance (i) that the activities' auth'orized by this amendment can be conducted without endangering the health and safety of-the public, and (ii) that such activities will be
-conducted in compliance with the Comission's regulations; The issuance of this amendment will not be inimical' to the cocmon D.-
defense and security or to the health and safety of the public; and E.
Th'e issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.
8112280023 811124" PDR ADOCK 05000344 P
pop
, > ~. - - -
-~..>.m-mem---,n,,,. -.
--,-,y n
,.--r
,,,,,-r-m.,-,
,v,--n-,
-u
,--,-e--r,ws,
,vw--,-.w
e 2-2.
Accordingly, the license is amended by changes to the Tec'hnical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License-No. NPF-1 is hereby amended to read as follows:
.(2) Technical Soecifications The Technical Spacifications contained in Appendices A and B, as revised through Amendment No. 69, are hereby incorporated in the license. The licensee shall A*s operate the facility in accordance with the Technicil Specifications, except as noted in p~aragrapfi 2.C.(ll) beloW.'?,_g3%,
. nc--
3.
This license amendment is effective as of the date of its issuance.
^- - -
FOR THE NUCLEAR REGULATORY COMMISSION
~~
w.,
Robert A. Clark, Chief Operating Reactors Branch #3 Division of Licensing
Attachment:
Changes to the Technical Specifications Date of Issuance:
November 24, 1981 f
I a
e e
H
_y v-
ATTACHMENT TO LICENSE AMENDMENT AMENDMENT NO. 69 TO FACILITY OPERATING LICENSE NO. NPF-1 DOCKET NO. 50-344 Revise Appendix A as follows:
Remove Pages Insert Pages 3/4 3-49 3/4 3-49 3/4 3-49a 3/4 3-49b 3/4 7-29 3/4 7-29 3/4 7-30 3/4 7-30 w.,
4 e
~~
f J
.a
--y-,m---v q..n-.n,..v w, w, m,+ v n.,,,w en
,,,,v,-,,,,n+,sr,-,w,-,e.n_,,.,,..-+,,,,,e
,_e
--,-m-gr-.--,.--,,..
-m,--,--
,,,n-w,,.
v-e~.
l r
TABLE 3.3-10 FIRE DETECTION INSTRUMENTS' INSTRUttENT LOCATION MINIMUM INSTRUffENTS OPERABLE * -
Smoke 1.
Control Roon a.
FIU 6-100, Zone 1 1
b.
FIU 6-100, Zone 2 2
c.
FIU 6-100, Zone 3 1
~
d.
FIU 6-100, Zone 4 1
Total 5
2.
Cable Spreading Room a.
ZIU 6-#2, Zone 1 3
b.
ZIU 6-#2, Zone 2 3
c.
ZIU 6-#2, Zone 3 3
~
d.
ZIU 6-#2, Zone 4.
3 Total 12 3.
Electrical Penetration Area 2
a.
ZIU 6-#5, Zone 1 1
b.
ZIU 6-#5, Zone 4 Total
,3 4.
Switchgear Room a.
Train A Elevation 69 ft (1) ZIU 6 37, Zone 1 3
(2) ZIU'6-#7, Ione 2 3
Total 6
e$
TROJAN-UNIT 1 3/4 3-49 Amendment No. 78, 50,6 9
INSTRUMENT LOCATION MINIMUM INSTRUMENTS OPERAB'LE*
Smoke b.
Train B Elevation 61 ft (1) ZIU 6-#6, Zone 3 2
(2) ZIU 6-#6, Zone 4
'l Total 5
5.
Station Battery Rooms a.
Train A Elevation 63 ft ZIU 6-#6, Zone 2 1
b.
Train B Elevation 63 ft ZIU 6-f6, Zone 1 1
6.
Containment
(
a.
IIU 6-#5, Zone 2 1
b.
ZIU 6-#5, Zone 3 1
c.
IIU 6-#19, Zone 3 1,
Total 3
7.
Auxiliary Feedwater Pump Rooms a.
ZIU 6 416, Zone 1 1
b.
ZIU 6-#16, Zone 2 1
c.
71U 6-#16, Zone 3
'l Total 3
8.
Residual Heat Removal Pump Rocms a.
ZIU 6-#13, Zone 1 2
b.
IIU 6-#13, Zone 2 2
Total 4
9.
Service Water Pump Area a.
IIU 6-#8, Zone 1
.1 b.
ZIU 6 48, Zone 2 1
1 c.
?IU 6 48, Zone 3 Tot 41 3
l TROJAN-UNIT 1 3/4 3-49a Amendment No. JB, 50, 6 9
INSTRUMENT LOCATION MINIMUM INSTRUMENTS OPERABLE
- Smoke
- 10. Service Water Booster Pump Area a.
ZIU 6 49, Zone 1 1
b.
ZIU 6-#9, Zone 4 1
Total 2
- 11. Centrifugal Charging Pump Rooms a.
ZIU 6-#14, Zone 2 1
i 1.
b.
ZIU 6-#14, Zone 3 Total 2
12.
Emergency Diesel Generator Rooms a.
ZIU 6-#15, Zone 1 2
b.
ZIU 6-#15, Zone 2 2
w.,
~
Total 4
- 13. Component Cooling Water Pump Area a.
IIU 6-#9, Zone 2 1
b.
IIU 6 49, Zone 3 1
Total 2
14.
Safety Injection Pump Rooms a.
ZIU 6 413,_ Zone 1 2
b.
ZIU 6 d13, Zone 2 2
Total 4
The fire detection instruments located within the Containment are not required to be OPERABLE during the performance of Type A Containment leakage Rate Tests.
TROJAN. UNIT 1 3/4 3-49b Amendment No. JE, 50, 6 9
PLANT SYSTEMS FIRE HOSE STATIONS LIMITING CONDITIONS FOR OPERATION 3.7.8.3 The fire hose stations shown in Table 3.7-4 shall be OPERABLE.
APPLICABILITY: Whenever equipment in the areas protected by the fire nose stations is reouired to be OPERABLE.
ACTION:
a.
With or.e or more of the fire hose stations shown in Table 3.7-4 inoperable, route an additional equivalent capacity fire hose to the unprotected area (s) from an OPERABLE hose station wihin 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. Restore the fire hose station to OPERABLE status within 14 days or, in lieu of any other report required by Specification 6.9.1, prepare and submit a Special Report to the Commission,
pursuant to Specification 6.9.2 within the next 30 days outlining the action taken, the cause of the inoperabil-ity, and plans and schedule for restoring the station to OPERABLE status.
ms.,,
- b. 'The provisions of Specifications 3.0.3 and 3.0.4 are not applicable.
SURVEILLANCE REQUIREMENTS 4.7.8.3 Each of the fire hose stations shown in Table 3.7-4 shall be demonstrated OPERABLE:
At least once per 31 days by visual inspection of the station a.
to assure all reouired ecuipment is at the station. Fire hose stations which are not accessible durino' plant operation shall be inspected during each cold shutdown exceeding 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> unless performed in the previous 31 days.
b.
At least once per 18 monthy by:
1.
Renoving the hose for 11spection and re-racking, and 2.
Inspecting all gaskets and replacing any degraded gaskets in the couplings.
c.
At least once per 3 years by:
1.
Partially opening each hose station valve to verify valve OPERABILITY and no flow blockaoa.
2.
Conducting a hose hydrostatic test at a pressure at least 50 psig greater than the maximum pressure available at that hose station.
TROJAH-UNIT 1 3/4 7-29 Amendment No. 78, E0, 8 9
l
.t TABLE 3.7-4 FIRE HOSE STATIONS 1
LOCATION ELEVATION HOSE STATION j
1.
Auxiliary Building 5 ft.
HS-34 2.
Auxiliary Building 25 ft.
HS-33 3.
Aux 111ary Building 45 ft.
HS-19, 38 4.
Auxiliary Building 63 ft.
HS-29 5.
Auxiliary Building 77 ft.
HS-28 6.
Turbine Building 45 ft.
HS-3, 5 7.
Turbine Building 69 ft.
HS-27 8.
Turbine Building 93 ft.
HS-15 7,
9.
Control Building 63 ft.
HC-2.
- 10. Control Building 77 ft.
HS-26 CHS-A[a,b]
- 11. Containment 45 ft.
CHS-B[a,b]
- 12. Containment 93 ft.
- 13. Containment 93 ft.
CHS-C[a,b]
[a] From Demineralized Water System
[b] Inspected During COLD SdUTDOWN
~
TROJAN-UNIT 1 3/4 7-30 Amendment No. W, 6 9
-