ML20039B873

From kanterella
Jump to navigation Jump to search
Notification of 820105 Meeting W/Util in Bethesda,Md to Discuss Status of Weld Preservice/Inservice Insp Program. Agenda Encl
ML20039B873
Person / Time
Site: Byron  
Issue date: 12/16/1981
From: Chesnut S
Office of Nuclear Reactor Regulation
To: Youngblood B
Office of Nuclear Reactor Regulation
References
NUDOCS 8112240088
Download: ML20039B873 (4)


Text

a DEC 161981 Docket Nos.: STN 50-454 and STN 50-455 HEMORANDUM FOR:

B. J. Youngblood, Chief, Licensing Branch No.1. DL FROM:

S. H. Chesnut, Project Manager, Licensing Branch No. 1, DL

SUBJECT:

FORTHCOMING MEETING WITH COMMONWEALTH EDISON COMPANY - BYRON DATE AND TIME:

January 5, 1982 9:00 am - 12:00 pm LOCATION:

Westinghouse Offices 4901 Fairmont Ave.

Bethesda, Maryland PUR00SE:

To discuss status of weld preservice/ inservice inspection program related to the Byron Station..

PARTICIPANTS:

NRC Staff S. Chesnut. K. Kiper, M. Hum, C. Y. Cheng, J. F. Cook, B. Brown Corirnonwealth Edison Company T. Tramm, L. Bowen, et al S. Chesnut, Project Manager Licensing Branch No. 1 Division of Licensing

Enclosure:

Proposed Agenda cc: See next page

~8112240088 811216

'PDR ADOCK 05000454 G

PDR DL:

1 DL

(

DL:LB#1

.:y..g./;,,,>.c omca>

SURNAME) t/.yt. KK$permmm.m BJ..Y.o..u n g b...l.o

...mm mm m..m......m.m..

m.

..m....m m

..m. mm mm.m.

.m m m..m m.m..

....../...../. 81

..12. 0...../. 8..1......

12./../ 7../. 81.......

12 or.re >

. nac ronu m ono> nacu ano OFFICIAL RECORD COPY usom --mm

s

. Mr. Louis.0. DelGeorge Director of Nuclear Licensing' Commonweal th -Edison Company Post Office Box 767 i

Chicago, Illinois 60690 ccs:

Mr.' William Kortier U. S. Nuclear Regulatory Commission Atomic Power Distribution Resident Inspectors Office Westinghouse Electric Corporation 4448 German Church Road P. O. Box 355 Byron, Illinois 61010

.Pittsburgh, Pennsylvania 15233 Ms. Diane Chavez Paul M. Murphy, Esq.

602 Oak Street, Apt. #4 Isham, Lincoln & Beale Rockford, Illi.no'is 61105 One First National Plaza 42nd Floor 4

Chicago, Illinois 60603 Mrs. Phillip B. Johnson 1907 Stratford Lane Rockford, Illinois 61107 i

Ms. Bridget-Little Rorem Appleseed Coordinator 117 North Linden Street

~

Essex,- Illinois 60935 Dr. Bruce von ZelM n Department of Biological Sciences Northern Illinois University DeKalb, Ill.inois 61107 l

Mr. Edward R. Crass Nuclear Safeguards and Licensing Divi; ion Sargent & Lundy Engineers l

. 55 East Monroe Street Chicago, Illinois 60603 Nuclear Regulatory Commission Region III Office of Inspection and Enforcement 799 Roosevelt Road i

Glen Ellyn, Illinois 60137 Myron Cherry, Esq.

Cherry, Flynn and Kanter.

1 IBM Plaza, Sui te ~4501-Chicago, Illinois 60611 j

4 e

e-e--s-e,---

v.

, w

-ww er

-m,--er..,,-o,.

,,ew

-w w q"

--~-*e-~,~

s

--,,.,e.

me.,w

-v w-w

-.wwy..e=-.y*

- y r,wr-~----

8

-AGENDA FOR BYRON UNIT 1 PRESERVICE INSPECTION MEETING January 5, 1982 Time: 9:00 AM - 3:00-PM 1.

Objectives of Review.

2.

Overview of-Schedule and Status of PSI.

3.

Explanation of the Concepts Used to Select Cla:s l' and 2 Piping System Welds and Exemptions Based.on IWB-1220 and IWC-1220.

4.

Examination of Cast Stainless Steel Primary Piping - Techniques.

Equipment, Calibration Blocks, and Results.

5.

Reactor. Vessel Examination - Procedures, Calibration Blocks, Results, Areas that are Impractical to Examine, Electronic Gating, and Regulatory Guide 1.150.

6.

Piping System Examinations - Procedures Examination. Coverage, Practice with One-Side Access, Practice with Limitations to Examinatirls, and Results.

7. - Examination Procedure for Bolts and Studs 8.

Discussion of Relief Requests 9.

Questions and Discussions.

i i

i.

r i

f

h r

MEETING NOTICE DISTRIBUTION E0iBiii1I5E25!

J. S'tolz

/-

NRC'PDR DEC 16 g)

%r

//

S. Hanauer Local PDR P. Collins Sge D D 5' TIC D. Vassallo of.

~ TERA T. Murley OECgEI981h.

'1 NSIC D. Ziemann

~

7 k,y'ag/,y 6 k %g P. Schroeder gs LBd1 Rdg.

DC "M

E. Case K. Kniel G>

cl N8 D. Eisenhut/M..Jambor D. Skovholt

/

2d

'l' G. Knighton-s, T. Novak M. Ernst S. Varga R. Baer

-l T. Ippolito E. Adensam'

.R. A.-C1 ark A. Thadani ACRS (16)'

j Attorney, OELD J. Youngblood 0IE (3)

A' Schwencer OSD(7)-

F. Miraglia Project Manager Schesnut J. R. Miller Licensing Assistant M. Rushbrook G. Lainas Receptionist D. Crutchfield W. Russell J. LeDoux, I&E J. Olshinki R. Vollmer I&E Headquarters R. Bosnak I&E Region I F. Schauer I&E Region II R. E. Jackson I&E Region III G. Lear-I&E-Region IV W. Johnston I&E Region V S. Pawlicki V. Benaroya NRC

Participants:

Z. Rosztoczy W. Haass SChesnut D. Muller KKiper R. Ballard MHum W. Regan CYCheng-V. Moore JFCook, EG&G R. Mattson

.BBrown, EG&G P. Check F. Congel 0, Parr bcc: Applicant & Service List-F. Rosa W. Butler W. Kreger l

R. W. Houston W. Gammill L. Rubenstein T. Speis M. Srinivasan B. Grimes '

S. Schwartz

'F. Pagano S. Ramos J. Kramer