2 REQUEST FOR ADDITIONAL INFORMATION EQUIPMENT E!NIRONMENTAL QUALIFICATION (EEQ)

REVIEW OF LICENSEES' RESOLUTION OF OUTSTANDING ISSUES FROM NRC EQUIPMENT EINIRONMENTAL QUALIFICATION SAFETY EVALUATION REPORTS (SER) AND TMI ACTION PLAN INSTALLED EQUIPMENT Florida Power and Light Company Turkey Point Unit 3 NRC Docket No. 50-250 December 11, 1981 NRC TAC No. 42470 d

t l

n or 8112 Heb3Of Lpe l

4 Franklin Research Center A Division Of The Franklin Insttute l

The Benpan Fraren Partrwey. PMa.. Pa. 13103 (213) 448 1000

=

e

f RFI-C5257-479 1'

BACKGROUND

'I Franklin Research Center (FRC) of Philadelphia, Pa. is providing assis-tance to the U.S. Nuclear Regulatory Commission (NRC) for the equipment environmental : qualification (EEQ) review of operating reactors.

FRC will perform an EEQ review of the Licensee's 90-day response to outstanding issues from the NRC Equipment Environmental Qualification Safety Evaluation Report (SER) and dhe~ installed THI Action Plan equipment. The review will be limited to safety-related equipment potentially exposed to a harsh environment. The o

results will be pre *:ented in the form of a technical evaluation report for

)

eacn' plant.

This request for additional information (RFI) is the result of an evaluation of the information provided by letters dated June 2,1980 [1] and ugust, 1981 [2].*

FRC previously requested TMI Action Plan information by a telephone memorandum dated August 14, 1981 [3].

In response to that request, Florida Power and Light Company provided the follcwing information on August t

14, 1961:

1. The cable description for the cable listed on SCEW Sheet 13-29:

W-C Cross-linked polyethylene insulation with a neoprene jacket.

t A.

FRC' REVIEW OF THE LICENSEE'S 90-DAY RESPONSE IV THE NRC EEQ SER f

Information Requested Date Received by FRC**

l l

1.

In reference to the Licensee's 90-day response [2] to the NRC SER [4], a legible single copy of each of the following l

qualification documents is requested in order that the FRC evaluation may proceed. The identification of those reports considered to be proprietary is requested so that proper control of documents can be maintained:

a.

Fischer & Porter Letter 3-6-75 with Ameron Lab Test #1550a dated 3-23-72 (Ref. 8) h

  • Numbers in brackets refer to citations found in the list of references.
    • This column will be completed by FRC as the requested information is received.

l l

-_ch._ Center nklin Resear

=

RFI-C5257-479 Date Received by FRC**

b.

Westinghouse Letter NS-CE-1586,10-28-77 (Ref. 9) c.

Joy Engineering Test Report 1969, V.P.

5 610-M-39-41-1 ( Ref. 10) d.

FPL Letter L-75-247 to NRC, May 21, 1975

( Re f. 18) e.

Engineering Analysis of Dousing Valves (Ref. 21) f.

Analysis of Operating Time for Devices Covered in IE Bulletin 79-OlB Master List (Ref. 22) 9 Raychem Letter 4-14-80 on Heat Shrinkable Tubing "RNF-100" (Ref. 23) h.

Okonite Letter (March-22, 1971) to Bechtel and IEEE Transactions Paper, Vol.

PAS 88, No. 5 May 1969 (Ref. 24) 1.

Bechtel Letter (April 7. 1980) to Okonite and Okonite Reply (April 10, 1980) (Ref.

25)

j. Engineering Analysis of Crouse-Hinds Penetrations (Ref. 26) k.

Westinghouse Specification Sheets for Instruments (Ref. 27) 1.

A Status Report on G.L*

Wire and Cable Department Comprehensive Testing Program with Cover Letter from G.E. dated May 30, 1949, and Mathematical Analysis (Ref. 29) m.

Engineering Analysis of Thermocouple Extension Wire (Ref. 30) n.

Continental Wire & Cable Test Report and Mathematic Analysis (Ref. 31) o.

Charcoal Filter Temperature Elements -

Environmental Qualification - Engineering Analysis (Ref. 32)

Nbranklin Resear.ch Center A w # m rr

.m

.RFI-C5257-479 Date Received by FRC**

p.

Containment-Vent Air Flow Switches -

Environmental Qualification - Engineering Analysis (Ref. 33) q.

ITT Barton Quality Release for Level Transmitters (Ref. 34) r.

Engineering Analysis for Replacement Solenoid Valves (Inside Containment)

(Ref. 35) s.

Fischer & Porter Differential Pressure Transmitter - Temperature Extrapolation (Ref. 36) t.

Engineering Analysis of Mackworth G. Rees Local Control Stations (Ref. 38) u.

Scotch Type 23 Electrical Tape - Product Data & 3M Letter of 4-14-80 (Ref. 39) v.

Static 0 Ring Pressure Switches -

Engineering Analysis on Qualification (Ref. 41)

Engineering Analysis on Qualification of" w.

Motorola Pressure Transmitters (Ref. 42) x.

Engineering Analysis of RCS to RHR Inlet Isolation Valves (Ref. 45) y.

Environmental Qualification / Analysis of United Electric Pressure and Level Controllers (Ref. 46) z.

Engineering Analysis - Qualification of Solenoid Valve in Auxiliary Building and Steam Line Break Areas (Ref. 48) aa.

Engineering Analysis Charcoal Filter Dousing Valvas (Ref. 49) bb.

Qualificaton Analysis for NAMCO Limit Switches (Ref. 50) cc.

Isomedix Test Report for Instrument Cable for PT-406 and PT-407 RCS Pressure Transmitters (Ref. 51)

_nidin Resea_rch._ Center

_g RFI-C5257-479 Date Received by FRC**

dd.

Qualification of Replacement NAMCO Controls Limit Switch Model EA-180-ll320 (Ref. 52) ee.

Engineering Analysis for Aging of Devices Covered in IEB-7901B Master List (Ref. 53) ff.

General Electric Letter to Bechtel dated May 16, 1980 (Ref. 56) gg.

Engineering Analysis of ITT Barton Pressure Controllers & Differential Pressure Switches (Ref. 55) hh.

Chempump Letter to Bechtel dated June 10, 1980 (R2f. 56) 11.

Fisher Controls Letter to FPL dated May 2,1980 and Type 546 Bulletin (Ref. 57) jj. Engineering Analysis-Radiation Detectors RD-ll, RD-12 (Ref. 58) kk.

Engineering Analysis of Dayton Motors (Ref. 59) 11.

Engineering Analysis and Product Specifications for Foxboro Instruments (Ref. 60) mm.

Qualification Test Report No. 770831 for PYCO Temperature Detectors (Ref. 61) (FRC previously requested this information in Reference 3]

nn.

Rockbestos Qualification Test Report, of June 7, 1978 for Firewall III Class lE Electric Cables (Ref. 63) oo.

Qualification Test Report (T.E.C. No.

517-TR-0 3) for Environmental and Seismic Testing (Rei. 64) nklin Research Center A Dmeson of The Frusen m

RFI-C5257-479 REFERENCES 1.

R. E. Uhrig Letter to J. P. O'Reilly (NRC)

Subj ect: Response to Items 1, 2, and 3 of IE Bulletin 79-OlB Florida Power & Light Co., 02-Jun-80, L-80-166 2.

Environmental Qualification of Electrical Equipment - IE Bulletin 79-01B; Response to the Safety Evaluation Report by the Office of Nuclear Reactor Regulation Florida Power & Light Co., August 1981 3.

Telephone Memorandum M. Williams, M. Grotenhaus, T. Le (NRC); D. Channey, L. Craig, R.

Kaminsky (FP&L); and C. J. Crcne, R. Krapf, W. Steigelmann (FRC)

Subject:

TMI-Action Plan deview Request for Additional Information Dated August 14, 1981 4.

Office of Nuclear Reactor Regulation Safety Evaluation Report for Turkey Point Units 3 and 4 Environmental Qualification of Safety Related Electrical Equipment NRC, 21-May-81 5.

R. E. Uhrig

^

Letter to J. P. O'Reilly (NRC)

Subject:

Supplements to Response to IE Bulletin 79-OlB, Supplement 3 dated July 3, 1980 Florida Power & Light Co.,12-Feb-81, L-81-49 6.

NUREG-0737, " Clarification of TMI Action Plan Requirements" NRC, November 1980 Y~

UN, c' Franklin R acm aa.#nesearch C. enter r

.