_.

~.

30 D

Qt December 7,1981 Docket No. 50-29 w

4 LS05-81 12-023 s

a@b%

Mr. James A. Kay DECg t7-IS81A Q Senior Engineer - Licensing

u.,kb

'1/

Yankee Atomic Electric Company 2

1671 Worcester Road g

Framingham, Massachusetts 01701 2

Dear Mr. Kay:

SUBJECT:

REQUEST FOR ADDITIONAL IhFORMATION FOR SEP T0FIC VI-4, CONTAINMENT ISOLATION SYSTEMS (YANKEE R0WE)

During our review of SEP Topic VI-4, " Containment Isolation Systems" we found that additional information (see enclosed) is needed to complete our review. Provide your response within 30 days of the receipt of this letter so that our evaluation can be completed in a timely manner.

The reporting and/or recordkeeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is not required under P.L.96-511.

Sincerely, Dennis M. Crutchfield, Chief Operating Reactors Branch No, 5 Division of Licensing

Enclosure:

As stated cc w/ enclosure:

See next page

/[dl: flen haA sw 3

Osa a SA Afhl)

O!ddh g

SEPB:DL g...

stru.v M..,...SEPB:DL ORB #5:PM

,O A(:

DL

,,, 6

........(.....

k. rutchfiel<l G as sun ~4ue)

. sbr,owfridk, R,Hermann

WRussell, RC, o

~..I dl.f.l.?l.....

..l.&l2.l.Q)..

..).?/.gl.8)..

..).2/.k,,,.,a]...12g/81..

..12/A../81..

oart y NRC FORM 318 (10-80) NRCM 024o OFF1ClAL RECORD COPY usom m-m.m

L

~f 3

Mr. James A. Kay CC Mr. James E. Tribble, President Yankee Atomic Electric Company 25 Research Drive Westborough, Massachusetts 01581 Greenfield Community College

~

1 College Drive Greenfield, Massachusetts 01301 Chairman Board of Selectmen Town of Rowe Rowe, Massachusetts 01367' Energy Facilities Siting Council 14th Floor One Ashburton Place Boston, Massachusetts 02108 U. S. Environmental Protection Agency Region I Office ATTN: Regional Radiation Representative i

JFK Federal Building Boston, Massachusetts 02203 Resident Inspector Yankee Rowe Nuclear Power Station c/o U.S. NRC Post Office Box 28 Monroe Bridge, Massachusetts 01350 T

a d

l 4

Enclosure

?

4-REQUEST FOR ADDITIONAL INFORMATION SEP TOPIC VI-4, C0'NTAINMENT ISOLATION SYSTEM YANKEE R0WE NUCLEAR POWER STATION DOCKET NO.50-029 1.

Provide updated information regarding the containment isolation provisions for all containment penetrations, including pipe penetrations, spare pene-trations, fuel transfer tube, equipment hatch, and personnel. air lock (s).

Include the following information in tabular form:

.a.

Containment penetration number; b.

System affiliation /line function; c.

Fluid contained; d.

Line size (inches);

e.

Essential or non-essential; f.

Reference to P&ID showing arrangement of containment isolation barriers; g.

Isolation. valve number; h.

Location of valve (inside or outside containment);

i.

Valve type and operator; j.

Primary mode of valve actuation; k.

Secondary mode of valve actuation; 1.

Normal valve position;

~

m.

Shutdown valve position; n.

Post-accident valve position; o.

Power failure valve position; p

Containment isolation signals; q.

Valve closure time; and r.

Power source.

2.

Where blind flanges are used as isolation barriers, verify that they are leak testable.

3.

For those systems penetrating containment which justifiably use remote manual isolation valves, discuss the provisions for detecting system leakage for the purpose of alerting the operator of the need to isolate the affected system or system train.

O G

e y

- --.-