Safety Evaluation Supporting Proposed Change 13 Re V Fuel Reload
ML20037B231
Person / Time
Site: Dresden 
Issue date: 02/23/1967
From: Boyd R
US ATOMIC ENERGY COMMISSION (AEC)
To:
Shared Package
ML20037B230 List:
References
NUDOCS 8009080620
Download: ML20037B231 (5)


Text

_

~.

p v

SAFETY EVALUATION BY THE RESEARCH AND 1%'ER REACTOR SAFETY BRANCH DIVISION OF REAC'IOR LICENSING IN THE MATTER OF COMMON'EALTH ED'ISON COMPANY DOCKET N3 50-10 PROP 3 SED CHANGE NO.13, TYPE V FUEL REIDAD Introduction Cc=nonwealth Edison Company has requested, by applications dated October 6,1966, January 9,1967 and January 31,1%7, authorization to load up to 106 Type y fuel assemblies, to load four special Type III-F fuel assemblies and to modify the Type SA-1 fuel assembly in the Dresden I reactor during its forthcoming refueling.

Discussion i

The proposed Type V fuel is physically very similar to the Type III and Type III-F fuel presently in the reactor. The principal difference is that the Gd2 03 (gadolinia) burnable poison is carried in selected UO2 (urania) rods for the Type V fuel rather than in a single alumina rod as previously used in some of the Type III-F fuel.

Included in the 106 Type V fuel assemblies are six special pilot assemblies; four have reduced claddin6 vall thickness and two utilize spacert, made of Zircaloy rather than stainless steel and have dished pellets in selected reds.

The four special Type III-F fuel assemblies differ from the other Type III-F i

fuel asse=blies by having one Fu (plutonium) enriebed rod in their 36 roa bundle.

i These special fuel assemblies vill not contain burnable poisons.

The amount of plutonium enrichment ranges from 1.2 to 1 7 veight percent.

Ta'cle I, attached hereto, presents a comparison of the characteristics of these types of fuel elements with Type III fuel elements presently in the Dresden I reactor.

The modification to the Type SA-1 fuel assembly consists of removing and not replacing five fuel rods from the upper half and five. fuel rods from the lower half of the assembly.

8000080[Q.O

- The fuel loading proposed is basically a uniform scatter of the new fuel as enployed in previous fuel cycles.

The combination of the characteristics of the new fuel with the present charneteristics of the residual fuel'results in the least reactive core loading yet used in the Dresden I reactor. At approxi-r.ately 2/3 of the way through this proposed fuel cycle, the core is expected to be at its most reactive condition which is expected to be at least 1% less reactive than prior cores.

The temperature and void coefficients of reactivity for the full core mixed lattice have been calculated to be negative at operating temperatures (5460F).

The temperature coefficient makes a transition from positive to negative at 0

about h20 F.

The behavior of these coefficients for this proposed core is the same as their behavior for the previous cores.

One reduction in the axial peaking factors due to the Type V fuel vill result in a lover gross peak power for this core, but the magnitude of power mismatch between fuel bundles remains similar to previous reloads.

However, due to the burnup characteristics of the gadolinia poison, the Type V reload fuel vill have its greatest power density at some time other than the beginning of this fuel cycle.

Type V fuel vill use gadolinia in lover concentrations than have been used in "ype III-F fuel. For the low concentrations being used in Type V fuel, the gadolinia goes into solid colution with the urania and gives a very uniform mixture that vill have a negligible effect on the thermal and mechanical properties of the U3 -

2 The two special assemblics of Type V fuel using Zircaloy instead of stainless steel spacers will have a slight reactivity increase of about.00254k causing an increase in the power mismatch factor of approximately 1.4%.

This small change should cauce no problem sssociated with maximum beat flux limits.

The four special assemblies of Type V fuel with thinner cladding vill cause a ~

decreace in tne ' vater to fuel volume ratio with a resulting decrease in reactivity; therefore, a reduced power mismatch factor.

Consequently, these asser.blies vill be operating at a lower power level than their thicxer clad counterparts.

The four special assemblics of Type III-F fuel enriched with plutonium bare a pe::,k heat flu:: of P75,000 ETU/br-ft vbich is below the pean beat flux of the standard Type III-F fuel assemblies. The fuel is in the form of mixed 2 - U3 ) hot-pressed pellets.

oxide (pus 3

The fuel rods to be removed from the Type SA-1 fuel assembly vill be selected to that no rods in the two-by-two location of the vide-vide water gap are re.cved ar.d that no tto rods laterally or diagonally adjacent or vertically inline are removed.

. Evaluation If the gadolinia depletion rate is fauter than anticipated, the control rode can be inserted to control reactivity and maintain good power distributions.

If the rate is slover, the reactor may have to be operated at a lower power level or shut down sooner than anticipated.

The proposed core vill have essentially the same power distributions as the previously evaluated core and the Type V fuel is physically similar to the Type III and Type III-F fuels; therefore, there vill be no significant dif-ference in the thermal and byiraulic characteristics during these two fuel cycles. This will permit the reactor to operate within the limits of the-previously evaluated beat flux and minimum critical beat flux ratio.

The six special pilot Type V fuel assemblies are considered developmental and until more experimental evidence is obtained, they are not being considered acceptable fuel types for extensive core loadings. They are an intermediate j

step in evaluating a more refined design bases for fuel assembly structure.

The amount of plutonium introduced into the reactor by the four special Type III-F fuel assemblies should not cause any additional radiological safety proclems as the quantity of plutoniun contained in these four rods is only two to, three times that contained in four typical irradiated rods in the present core (Type I fuel with 10,000 MWD /t operating at 20% void has 0 5% plutonium).

The Minimum Critical Heat Flux Ratio (MCHFR) at overpower conditions for the.

modified SA-1 fuel was evaluated to be between 2. D to 2 58 vnteb is well above the 1 50 MCHFR which is a limiting thermal vcive for this resetor.

{

sj The total of eleven special fuel assemblies discussed above have no significant effect on the surrounding fuel assemblies and overall core thermal and nuclear perfarmance.

Technical Seecificaticns To provide authorization of Proposed Change No.13, the Technical Specifications of License No. DPR-2 should be a:nended as follows:

l.

Oection B.2, page 1, is revised in its entirety, as follows:

" Maximum ecre diameter (circumscribed circle) 129 in.

Maximum active fuel length - cold 112 in.

Maximum number of fuel assemblies by types:

Type I 166 Type III 192 Type III-F (standard) 8S 2

U J

4 Type III-F (removable experimental segmented poison rod) 2 Type III-F (plutonium fuel rod) 4 Type III-F (powder) 10 Type V 106 Type PF-10 (modified) 1 Ty'pe SA-1 (modified) 1 l

Maximum total number of fuel assemblies k88 The reactor may be operated at any power up to and including rated power with any. configuration of the various types of fuel assemblies installed, provided the maximum number is within the limits specified above."

2.

The tabulation in Section D.3, pege 12, is amended to read as follows:

" Fuel Type I 350,000 Fuel Type III 360,000 Fuel Type III-F 360,000 Fuel Type V 360,000 Fuel ~ Type PF-10 510,000 Fuel Type SA-1 425,000" 3

Table II (revised March 16,1%5) should be replaced by Table II (revised January 31,1967) as transmitted in commonwealth Edison's letter of January 31, 1967 Conclusion Based upon our review of the information subcritted, we have concluded that operation of the reactor in accordance with the proposed caanse does not involve significant hazards considerations not described or -implicit in the hazards su m rny' report and that there is reasonable assurance that the health and safety of the public vill not be endangered.

Acco-dingly, we believe that the Technical Specifications of License No. DPR-2 may be revised as indicated above.

Original signed by:

Dover S. Dc::d Roger S. Boyd, Chief hecearch & Power Reactor Safety Branch Da. vision cf eactor Licensing Date : IEE 2 3 'i367 i

TABLE I COMPARISON OF T'-:I CHARACTERISTICS OF DRESDEN I TYPE III, TYPE III-F, AND TYPE V FUEL ASSEMBLIES Tyne III Type III-F Type V Cladding Material Zr-2 Zr-2 Zr-2 0.D., inches 0 555 0 5625 0 5625 1/

0.035 0.03$!

Vall thickness, inches 0.035 Configurations 6x6 6x6 6x6 Regular Rods Burnable Poison Er2 3 N ne /

cd 0 0

23 d/

2 34 l

7)2 Enrichment, %

1.83 23 b!

E!

Fuel Diameter, inches 0.k78 0.h82 0.482 Special Corner Rods Burnable Poison Er2 3 8 "*

0 102 Enrichment, $

1.83 1 77 1 77 Fuel Diameter, inches O.438 o.h82S/

o.h82E/

1/ Corner rods have a 0.055 vall thickness.

[/ Thin clad rdds not containing Gdp03 bave a 0.026 vall thickness.

l l

1/ A fev special test rods have varied burnable poison loadings using Gd 0 in Al 02 3 cr U22 or have 1.2 to 1 7% enrichment with Pu.

23 l

h.'

Powered fuel rods have a fuel diameter of 0.14925 l

5/ Thin clad rods have a fuel diameter of 0.h98.

1 i

l