ML20037A428

From kanterella
Jump to navigation Jump to search
Submits List of Items to Be Completed Prior to Initial Criticality:Filter Elements & Gas Waste Disposal Filter Housing Installation,Incore Cable & Equipment Hatch Bolt Replacement & Resolution of Items Re Preoperational Test
ML20037A428
Person / Time
Site: Oconee 
Issue date: 07/17/1974
From: Thies A
DUKE POWER CO.
To: Anthony Giambusso
US ATOMIC ENERGY COMMISSION (AEC)
References
NUDOCS 8001140849
Download: ML20037A428 (2)


Text

',s AEC DISTRI IC.i 70R PART 50 DOCKET MATERIA 6550 (TDiPORARY FORM)

CONTROL liO:

FILE:

FROM:

DATE OF DOC DATE REC'D LTR TWX RPT CTHER Duka Power Company Chcrictte, N.C. 28201 Mr. A.C. Thies 7-17-74 7-18-74 X

TO:

ORIG CC OTHER SENT AEC PDR N

A. Giambusso 1 sizned CLASS UNCLASS PROP INFO U;PUT NO CYS REC'D DOCKET NO:

XXX 1

50-287 DESCRIPTION:

ENCLOSURES:

Ler furn info concerning itens to be completed Prior to initial criticality......

7 $ 3 D*

D

.-~ -

gg.

o

, n[L D

TJEE ZJ.33 Oconee #3 W

JL a

PLANT N.25 FOR ACTION /IN'iORMATION 7_??.74 in BUTLER (L)

SCEWENCER(L)

ZID! MIN (L)

REGAN(3)

W/ Copics W/ Copies W/ Copies W/ Copies CLARK (L)

STOLZ(L)

DICIER (E)

LEAR (L)

W/ Copies W/ Copics W/ Copies W// Copies PA"R( L';

YA55 ALLO (L)

FIGEIn'3(E)

W/ Copics W/ Copies W/

Copies w/' copies ICTIEL(L)

PURPLE (L)

YOUNG 3LCOD(E)

W/ Copics W/ Copies W/ Copies W/ Copies INTER:!AL DISTRIP'ITION

/ REG FID TECH REVIEN DENTON LIC ASST A/T ISD

' y Ar.u FDR HEliDRIE GRHES BRAITMAN CGC, RCCI P-506A SCHROEDER GAPMILL DIGGS (L)

SALTZMAN MRiT21NG/ STAFF MACCARY KASTNER GEARIN (L)

3. HURT CASE KNIGHT BALLARD GOULBOURNE (L) ptg33 GIAMEUSSO PAULICKI SPANGLER KREUTZER (E)

MCDONALD l

BOYD SHA0 LEE (L)

CHAPMAN MOORE (L)(E;iR)

STELLO ENVIRO MAIGRET (L)

DUBE w/ input DEYOUUG(L)(IWR)

HOUSTON PULLER REED (E)

E. COUPE SKGVEOLT (L)

NOVAK DICKER SERVICE (L) i l

COLLER(L)

ROSS KNIGHTON SHEPPARD (L)

D. THOMPSON (2) l P. COLLINS IPPOLITO YOUNGELCOD SLATER (E)

KLECKER DD:ISE TEDESCO REGAN SMITH (L)

EISENHUT REG 0?R LONG PROJECT LDR / TEETS (L)

WILLIAMS (E)8 0 013 4 FILE & RECIOU(3)

LAINAS MORRIS BENAROYA HARLESS WILSON (L)

STEELE 70 LUER EXTE? MAL DISTRIIUTIO:1

/Id

./l - LOCAL FER Valhalla. S.C.

'[

hl-TIC (ABER'IATHY)

(1)(2X10)-NATIO:iAL LA3'S 1-PDR-SAN /LA/NY

  1. 1 - USICf?UCIN;AN) 1-ASLEP(E/'i 31dt,Rn 529) 1-LIBRARD.3 1 - ASLE l-W. PE:iNINGTON, Em E-201 GT BROCXF. WEN NAT. LA3 1 - P. 3. DAVIS (AEROJET NUCLEAR) 1-CCNSULTANT'S 1-AGSCD(Ruth Gussaani g 16 - CYS ACRS V,CCOC5X; Sent to Teets NER' ARK /3LOS/AG3ABIAN EM-3-12 7. GT.

7-22-74 1-GERALD ULRIKSCN.. 0:aii, 1-BD.. PULL'R..F-309 CI 1-B & M SUINE3RCAD, Rm E-201 GT e :,

74 ZE;.

5 3

DuxE PowEn COMPANY Powra Butz.orwo 422 SouTu Cucaczt SrazzT, CruaroTTz, N. C. assos A. C. Taras sc..o. v.cc hc..ccar P. O. Box 2 7e

~o-

-o v..

July 17, 1974

/g ghIi3.

y Mr. Angelo Giambusso

)/

Deputy Director for Reactor Projects N,,

[.

4.., [v ( ;._

Directorate of Licensing

. p Office of Regulation 2

r N

Jf h

, /g.f N U. S. Atomic Ene' ;y Commission Washington, D. C.

20545 g

p Re: Oconee Unit 3 Docket No. 50-287

Dear Mr. Giambusso:

The following items have been identified by Duke Power Company and AEC/R0 personnel as required to be completed prior to initial criticality:

1.

Install filter elements and gas waste disposal filter housing, penetration room and control room.

2.

Replace two missing incore detector cables.

3.

Insta13 two missing bolts on reactor building equipment hatch.

4.

Satisfactory resolution of outstanding items with regard to the following preoperational tests.

(a) TP/3/3/0200/23A - Reactor Coolant Pump Motors Test (b) TP/3/A/0202/07 - HPI Functional and Operational Test.

(c) TP/3/A/0600/11 - Emergency Feed System and Steam Generator Control Test.-

(d)

TP/3/B/0600/12A-Pressurizer Operational Test.

(e) TP/3/A/0161/03 - Reactor Building Purge System Functional and Operational Test.

(f) TP/3/A/0150/06 - Reactor Building Isolation Pneumatic Leak Test.

(g) TP/3/A/0600/17 - Integrated Engineered Saf?. guards Actuation Test.

Very truly yours,

,K

}, g, f,

' Jfjz k, E2 A. C. Thies U

ACT:gje

.if,.

N Dj

~

cc: Norman C. Moseley f

'dj//

$$/

/,ign\\

f3,{g

.*w_e.,

e,

,_