AEC DIWn2KhWN WN WA?.V 50 ccCiW l'ATERIAL

~

(TalPORARY FORM)

'i CONTROL NO:

8183 FILE:

FRCti:

DATE OF DOC DATE EC'D LTR TWX RPT CTHER Duk2 Power Cocpany Charlotte, NC 28201 8-5-74 8-8-74 X

A. C. Thies TO:

CRIG CC OTHER SciT AEC PDR X

A. Giambusso 3 signed SENT LOCAL PCR X CLASS C: CLASS PROP INFO INPUT NO CYS REC'D DOCKEI NO:

SXX 40 50-287 DESCRIPTION:

ENCLCSURES:

Ltr trans the fellowing:

Integrated, Leak Rate Test of the Reactor Cantainment Building, dtd 8-5-74 DO NOT REMOVE ACKNOWLFDo.gi)

PLANT NAME:

Oconee Unit.#3

( 40 cys rec'd ).

e. :, ~ i,/__

L, FOR ACTICN/!'7C "ATIC:'

8 o 74 cc BUTLER (L)

SCHWENCER (L)

ZIEMANN (L)

REGAN (E)

W/ CYS W/ CYS W/ CYS W/ CYS CLARK (L)

STOLZ (L)

DICKER (E)

W/ CYS W/ CYS W/ CYS W/ CYS ZAAA 'O 7A3 A.;G 'u UIGHTC

'E',

W/ CYS W/ CYS W/ CYS W/ CYS KNIEL (L)

/ PURPLE (L)

YOEiGELCCD (E)

W/ CYS W/ 9 CYS W/ CYS W/ CYS INTERNAL DISTRI5UTION OGEG FIQ TECH REVIEW DENTON LIC ASST A/T IND n/AEC PDR HENDRIE GRD!ES DIGGS (L)

BRAITMAN

/0CC SCHROEDER GAMMILL GEARIN (L)

SALTZMAN MUNTZING/ STAFF MACCARY KASTNER GOULBOURNE (L)

B. HURT CASE KNIGHT BALJ.ARD KREUT2ER (E)

GIAMSUSSO PAWLICKI SPANGLER LEE (L)

PLANS BOYD SHA0 MAIGRET (L)

MCDONALD MOCRE (L)(LWR-2)

STELLO ENVIRO REED (E)

CHAPMAN DEYOUNG (L)(LWR-1)

HOUSTON MULLER SERVICE (L)

DUBE w/ input SKOVHOLT()d NOVAK DICKER A HEPPARD (L)

E. COUPE

./bOLLER (L 1l ROSS KNIGHTON SLATER (E)

P. COLLIN IPPOLITO YOUNGBLCOD SMITH (L)

D. THO"PSCN (2)

DENISE TEDESCO REGAN TEETS (L)

KLECKER REG OPR LONG JROJECT 'GR WILLIAMS (E)

EISENHUT VFILE & REGION (3)

LADIAS

/ Scaletti WILSON (L)

MORRIS BENAROYA H/JtLESS A

8001100632 f

STEEtE votIxER E'CERNAL DISTRI3CTICN n

g41 - LCCAL PDR Walhallt. SC 6

M - TIC (A::LFJ;AI. )

(1)(2)(10)-::ATICNAL LASS 1-PD R-3A'; / LA e '.Y d - NSIC (BUCEC.N) 1-ASLSP(E/W Sid;,.;a M 9) 1-LRCCKHAVI:.

EL3 1 - ASL2 1-W. PE:.".:INGTON, Pa E-201 GT 1-G. ULRIGC', CR' L 1 - P. R. EAVIS 1-PAM SWINI3 ROAD, Fa E-201 GT 1-AG"ED (ZTd GU5f.,'.

vi6 - ACRS HCLDING 1-CONSULT.C:T2 Rm 3-127 C NEW".AfdUSLC'C /AG3ALIAN 1-RD..E*EL*.T., ?n ?- L--

GT

n

<\\

[{egdiat0ry Docket fil8 3

a

~

~

DUKE POWER COMPANY Powrn Burt.orwo 422 Sourn Cucacu SrazzT, CnAnLOT73, N. C. 3820s lN f'3 h Ss P. o. Box ai7e A. C. Tu t zs se.

wet % wee.,

t o.oaa.a.

a r.........o.

~ '

August 5, 1974

/!473,

[

9

//4 Y

~

g

.V g

x

,.), y gG 7,

N

"\\/ h:.

Mr. Angelo Giambusso Deputy Director for Reactor Projecte Directorate of Licensing 0)

U. S. Atomic Energy Commission A

g Washington, D. C.

20545

_ j' Re: Oconee Nuclear Station Unit 3 Docket No. 50-287

Dear Mr. Giambusso:

In connection with the Preoperational Test Program for Oconee Nuclear Station Unit 3, which is undergoing startup testing pursuant to Facility Operating License DPR-55, Duke Power Company submits herewith the " Integrated Leak Rate Test of the Reactor Containment Building."

Three (3) ccpies of the report are attached.

Thirty-seven (37) copies of the report are being transmitted under separate cover.

Very truly yours, A. C. Thies ACT:vr Attachments alc3 n

I

.