ML20036A980

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept for Apr 1993 for Ocnpp
ML20036A980
Person / Time
Site: Oyster Creek
Issue date: 04/30/1993
From: J. J. Barton, Krall J
GENERAL PUBLIC UTILITIES CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
C321-93-2143, NUDOCS 9305180034
Download: ML20036A980 (7)


Text

E

o g

GPU Nuclear Corporation

h. er QQ f

Post Office Box 38B Rome 9 Somb Forked River. New Jersey 08731-0388 609 971-4000 Wnter's Direct Dial Number:

C321-93-2143 May 11, 1993 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C.

20555

Dear Sir:

Subject:

Oyster Creek Nuclear Generating Station Docket No. 50-219 Monthly Operating Report i

In accordance with the Oyster Creek Nuclear Generating Station Operating License No. DPR-16, Appendix A, Section 6.9.1.C, enclosed are two (2) copies of the Monthly Operating Data (gray book information) for the Oyster Creek Nuclear

~

Generating Station.

If you should have any questions, please contact Brenda DeMerchant Oyster Creek Licensing Engineer at (609) 971-4642.

Sincerely, J.. B n

Vice President and Director Oyster Creek JJB/BDEM: jc Attachment (MOR-RPT.APR) cc:

Administrator, Region 1 Senior NRC Resident Inspector Oyster Creek NRC Project Manager 9305180034 93043o gDR ADOCK0500g9 GPU Nuclear Corporation is a subsidiary of Genera Pubbc Utalibes Corporation I

L

~.

SUtEARY APRIL. 1993 Oyster Creek entered April operating at full power. The plant maintained full power operation throughout the month and generated 450,476 net electric megawatt hours.

~

f MONTHLY OPERATING REPORT LICENSEE EVENT REPORTS i

The following Licensee Event Reports were submitted during the month of April, 1993:

None h

k i

l i

)

?

f i

i Oyster Creek Station #1 l

Docket No. 50-219 REFUELING INFORMATION - APRIL, 1993 i

Name of Facility:

Oyster Creek Station #1 i

Scheduled date for next refueling shutdown: Currently projected for September, 1994 Scheduled date for restart following refueling: Currently projected for December,1994 Will refueling or resumption of operation thereafter require a Technical f

Specification change or other license amendment?

No I

Important licensing considerations associated with refueling, e.g.,

new or different fuel design or supplier, unreviewed design or perf ormance analysis methods, significant-changes in fuel design, new operating procedures:

1.

General Electric Fuel Assemblies - Fuel design and performance analysis methods have been approved by the NRC.

The number of fuel assemblies (a) in the core 560

=

(b) in the spent fuel storage pool 1878

=

(c) in dry storage 8

=

The present licensed spent fuel pool storage capacity and the size of any increase in licensed storage capacity that has been requested or is planned, in number of fuel-assemblies:

Present Licensed Capacity:

2600 The projected date of the last refueling that can be discharged to the spent fuel pool assuming the present licensed capacity:

Based on a projected reload of 184 bundles, full core discharge capacity to the spent fuel pool will be lost after the 15R refueling outage (December, 1994).

NRC_RPT.WPD

.m

_.m.

... ~ _

-1 l.

.j AVERAGE DAILY POWER LEVEL l

NET MWe l

DOCTIT #.

.50-219 UNIT.

OYSTER CREEK #1 REPORT DATE.

05-03-93 COMPILED BY

. JIM KRALL TELEPHONE #..'

.609-971-4115 t

MONTH:

APRIL, 1993 I

plX M

DAY M

[

1.

627 16.

625 i

2.

629 17.

626

?

3.

629 18, 627

' l 4.

630 19.

626 i

5.

630

.20.

623

- 6.

629 21.

623 i

I 7

630 22.

621 l

?

8.

629 23.

626 9.

629 24.

626 l

10.

627 25.

622 11.

630 26.

620 1

l 12.

628 27.

623 13.

628 28, 626

_i l

14.

627 29.

626 l

l 15.

627 30.

627 l

i i

9

~h NRC_RPT.WPD

'l I

i i

~

-. ~

t

.. - ~

l c

OPERATING DATA REPORT 0

OPERATING STATUS

1. DOCKET:

50-219 l

2. REPORTING PERIOD:

04/93 l

3. UTILITY CONTACT:

JIM KRALL (609}971-4115 f

4. LICENSED TH*RMAL POWER (MWt):

1930

(

5. NAMEPLATE RATING (GROSS MWe):

687.5 x 0.8 = 550 t

6. DESIGN ELECTRICAL RATING (NET MWe):

650 l

7. MAXIMUM DEPENDABLE CAPACITY (GROSS MWe):

632 l

f B. MAXIMUM DEPENDABLE CAPACITY (NET MWe):

610

9. IF CHANGES OCCUR ABOVE SINCE LAST REPORT, GIVE REASONS:

NONE i

i

10. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWe):

NONE

11. REASON FOR RESTRICTION, IF ANY:

NONE

.t MONTH YEAR CUMULATIVE l

12. REPORT PERIOD HOURS 719.0 2879.0 204719.0
13. HOURS RX CRITICAL 719.0 1809.6 133718.0 i

i

14. RX RESERVE SHUTDOWN HRS 0.0 0.0 918.2 j

f

15. HRS GENERATOR ON-LINE 719.0 1733.4 130320.7
16. UT RESERVE SHIDWN HRS 0.0 0.0 1208.6 i

l 2

17. GROSS THERM ENERGY (MWH) 1386083 3366841 221835476 l

r

18. GROSS ELEC ENERGY (MWH) 467269 113*763 74529901

{

f j

19. NET ELEC ENERGY (MWH) 450476 1087241 71522757 l

?). UT SERVICE FACTOR 100.0 61.6 63.7 l

21. UT AVAIL FACTOR 100.0 61.6 64.2
22. UT CAP FACTOR (MDC NET) 102.7-61.9 56.5 l
23. UT CAP FACTOR (DER NET) 96.4 58.1 53.7 j
24. UT FORCED OUTAGE RATE 0.0 0.0 10.9 i
25. FORCED OUTAGE HRS 0.0 0.0.

15957.3 a

26. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE, DURATION):

1 NONE

[

t

27. IF CURRENTLY SHUTDOWN, ESTIMATED STARTUP DATE:

{

t N/A

.{

i

.NRC ?PT.WPD l

e f

l i

4 4

~

Q f

e e

i

( S R

d c. ba1 U E

) F P

04 O

R A R

RRME ER T

e e aq AY g f iu S :

N H

u uni O

O l e t p N

.o N

al e a T

nn t i onan il r g nt y

c eF R

a e

oi A

s r l r.

t u

r r

Tr t

i e e l

c s

(

1 t

t i

E 9

o m

D 9

n p

A 3

l T

a E

i n

)

,h s.

i e

SF OOAO t p dp he me SF co e r i r hr r ana e c t i t

( i s o de T ud Y Eot r l

P

~

x nr e

E p aaT d

l l t r a

i a iEvi nr e n

) r i

o n

r g

U

(

E N

I x

L T

p i

l c

S a

t E

H a

x UT D

D w

(h

)

n U

O R

W o

A N

u T

S r

I s

O A

)

N N

D P

(

O 4 3 2 1 2 W

)

E R

OAMMM

~

R t u a.

E FD ht nn T

e ouu H

U r ma a O

R C

al l D

E T

( t A

I EiS S

O xcc O

N

~

p r

N S

l Sa a cm

(

t r 1

nw

)

) n T

C D

U M.

E O

A N

RDM L

M T

I EOE E

P E

T DWT P

L N

TE UNH H

T C

O O

A I TD N

D' M

N PR

Y
E O

NH E

GEO B

F OES WAH n

ECU RT T 9

D M

O 5

OT 7

a a

y 0

( RI 1

v y

) OG 4

i s

2 N

t

?

n d

e 1

3 R

8 r

9 1

F 8

a 1

C

.a 9

r e

9 e

p t rs sT AC k

~

1 e he i hh CO r e dg ue TR i

unt r I R or cide OE de t f o NC ww S T p i t ooe ne

/ I r na ar CV t s n e

OE i

t o M

nd rn M

g up o

E r o N

iw T

ne S

g r

~

.