Application for Amend to License NPF-69,changing Action Statement a.2 of LCO 3.6.5.3 for Sgts.Action Statement Applies to Irradiated Fuel in Reactor Bldg
ML20036A055
Person / Time
Site: Nine Mile Point 
Issue date: 04/30/1993
From: Carns N
NIAGARA MOHAWK POWER CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20036A056 List:
References
NMP2L-1381, NUDOCS 9305070332
Download: ML20036A055 (4)


Text

.

M V NIAGARA R uMOHAWK NIAGARA MOHAWK POWER CORPORATION /301 PLAINFiELD ROAD, SYRACUSE, N Y.13212/ TELEPHONE (315) 474-1511 April 30,1993 NMP2L 1381 U. S. Nuclear Regulatory Commission Attn:. Document Control Desk Washington, D.C. 20555 Re: Nine Mile Point Unit 2 Docket No. 50-410 NPF-69 Gentlemen:

Niagara Mohawk Power Corporatic' hereby transmits an application for amendment to Nine Mile Point Unit 2 Operating License NPF-69. Also enclosed as Attachment A are two proposed changes to the Technical Specifications as set forth in Appendix A of the Nine Mile Point Unit 2 Operating License. Pursuant to 10CFR50.92, supporting information and an analysis demonstrating that the proposed changes involve no significant hazards consideration are included as Attachment B.

Both proposed Technical Specification changes are to action statement a.2 of Limiting c

Condition for Operation (LCO) 3.6.5.3 for the Standby Gas Treatment System (SGTS). The action statement applies to an operational condition defined as: activities involving the movement of irradiated fuel in the reactor building, core alterations and operations with a potential for draining the reactor vessel. With one SGTS subsystem inoperable, the current action statement permits these activities to continue for up to seven days.

The first proposed change to the action statement would permit these activities described above to. continue beyond seven ' days with one SGTS subsystem inoperable provided the operable SGTS subsystem is in operation. The second proposed change would exempt action statement a.2 of LCO 3.6.5.3 from the requirements of LCO 3.0.4. This would allow entry into the above defined operational condition for LCO 3.6.5.3 with an SGTS subsystem inoperable provided the operable SGTS subsystem is in operation. These proposed changes are consistent with the improved Technical Specifications developed by the Nuclear

. Regulatory Commission and the Boiling Water Reactor Owners' Group as presented in NUREG-1433.

These changes to the Technical Specifications will prevent delays in plant outages during movement of irradiated fuel, core alterations and operations with a potential for draining the reactor vessel when one SGTS subsystem is inoperable provided the operable SGTS '

subsystem is in operation.

060064 I

0 9305070332 930430 PDR ADOCK 05000410-

.I

\\

P PDR

\\

Page 2 Niagara Mohawk Power Corporation is requesting this license amendment be issued by September 27,1993. A copy of the license amendment request and the associated analysis which demonstrates that no significant hazards consideration exists have been provided to the appropriate state representative in accordance with 10 CFR 50.91(b)(1).

Sincerely, N. S. Carns Vice President - Nuclear Generation KWK/sek 003213LL Attachments xc: Mr. T. T. Martin, Regional Administrator, Region I Mr. W. L. Schmidt, Senior Resident Inspector Mr. R. A. Capra, Director, Project Directorate I-1, NRR Mr. J. E. Menning, Project Manager, NRR Ms. Donna Ross Division of Policy Analysis and Planning New York State Energy Office Agency Building 2 Empire State Plaza Albany, NY 12223 Records Management t

I 5

I

'l

1 i

}

UNITED STATES NUCLEAR REGULATORY COMMISSION l

i In the Matter of

)

l

)

t NIAGARA MOHAWK POWER CORPORATION )

Docket No. 50410 (Nine Mile Point Nuclear Station

)

i Unit No. 2)

)

.j APPLICATION FOR AMENDMENT TO OPERATING LICENSE l

Pursuant to Section 50.90 of the Regulations of the Nuclear Regulatory Commission, Niagara.

Mohawk Power Corporation, holder of the Facility Operating License No. NPF-69, hereby requests that action statement a.2 of Limiting Condition of Operation (LCO) 3.6.5.3 of the l

Technical Specifications as set forth in ' Appendix A to that License be amended. The two I

proposed changes have been reviewed in accordance with Section 6.5 of the Technical Specifications.

The proposed changes to the Technical Specifications are set forth in Attachment A to this.

j application. Both proposed Technical Specification changes are to action statement a.2 of LCO 3.6.5.3 for the Standby Gas Treatment System (SGTS). This action statement applies j

to an operational condition defined as: activities involving the movement of irradiated fuel in _

the reactor building, core alterations and operations with a potential for draining the reactor vessel. The current action statement permits the activities described above to continue for up to seven days with one SGTS subsystem inoperable.

The first proposed change to the action statement would permit these activities described above to continue beyond seven days with one SGTS subsystem inoperable provided the operable SGTS subsystem 's in operation. The second proposed change would exempt action statement a.2 of LCO 3.6.5.3 from the requirements of LCO 3.0.4. This would allow entry

. into the above defined operational condition for LCO 3.6.5.3'with an SGTS subsystem j

' inoperable provided the operable SGTS subsystem is in operation. These proposed changes -

1

~

are consistent with the improved Technical Specifications developed by the NRC and the Boiling Water Reactor Owners' Group as presented in NUREG-1433.-

t i

Supporting information and analysis which demonstrate that the proposed changes do not j

involve a significant hazards consideration pursuant to 10 CFR 50.92, is included as Attachment B.

l 003213LL Page 1 of 2 l

=

APPLICATION FOR AMENDMENT TO OPERATING LICENSE (Cont'd)

Wherefore, the applicant respectfully requests that Appendix A to Facility Operating License No. NPF-69 be amended in the form attached hereto as Attachment A.