Topical Rept Evaluation of NEDO-31558, Position on Reg Guide 1.97,Rev 3,Requirements for Post-Accident Neutron Flux Monitoring. Monitoring Instrumentation at Existing BWRs Should Meet Criteria in Topical Rept
ML20035F468
Person / Time
Site: River Bend 
Issue date: 04/19/1993
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20035F467 List:
References
RTR-REGGD-01.097, RTR-REGGD-1.097 NUDOCS 9304210318
Download: ML20035F468 (8)


Text

.-.

-~

t

/

b, UNITED STATES 8

NUCLEAR REGULATORY COMMISSION E

I usmworow o.c. mas

,e ENCLOSURE 1 SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION BOILING WATER REACTORS i

REGULATORY GUIDE 1.97 POST-ACCIDENT NEUTRON FLUX MONITORING INSTRUMENTATION

1.0 INTRODUCTION

.Section 6.2 of Generic Letter 82-33 (Reference 1) requests applicants and licensees to provide a report on their implementation of Regulatory Guide

{

\\

(R.G.) 1.97, Revision 2 (Reference 2), and methods for complying with the Commission's regulations including supporting technical justification of any proposed deviations or alternatives. A review of the applicants' and licensees' submittals was performed and a safety evaluation report (SER) was issued for each plant. These SERs conclude that the applicants and licensees either conformed to, or adequately justified deviations from the guidance of R.G.1.97 for each post-accident monitoring variable except for the variables identified in the SERs.

A large number of Boiling Water Reactor (BWR) applicants and licensees requested deviations from the regulatory guide position for Category I neutron flux monitoring instrumentation. The R.G. 1.97 Category I criteria includes i

environmental qualification, seismic qualification, Class Ir emr out tes, and redundant channels. Current operating BWRs, with the exception of Susquehanna Steam Electric Station Units 1 and 2 and Washington Public Power Supply Nuclear Project (WNP-2) do not have environmentally qualified neutron 9304210318 930419 PDR ADOCK 05000458 p

PDR

~

~.

2-flux monitoring instrumentation. However, none of the submittals requesting.

neutron flux monitoring instrumentat'on deviations provide sufficient justification for granting the deviations. These requests were denied to the applicants and licensees, except for Limerick Generating Station Units 1 and 2.

Additionally, Big Rock Point was granted an exemption from the provisions of R.G. 1.97.

In support of these requests the BWR Owners' Group submitted NEDO-31558

" Position on NRC Regulatory Guide 1.97, Revision 3, Requirements for Post-i Accident Neutron Monitoring System" (Reference 3). The NEDO report proposes criteria for neutron flux monitoring instrumentation, in lieu of the Category I criteria included in R.G.1.97, Revision 3 (Reference 4).

I The staff rejected the BWR Owners' Group proposal (Reference 5) because of the judgement that neutron flux is fundamentally a key safety parameter and l

l existing neutron flux monitoring instrumentation is not likely to survive a post-accident harsh environment. The BWR Owners' Group appealed the staff's l

position to the Director of the Office of Nuclear Reactor R,egulation (NRR) l (Reference 6).

l The Director of NRR upheld the appeal (Reference 7) and concluded that Category I neutron flux monitoring instrumentation is not needed _for existing -

BWRs to cope with Loss-of-Coolant Accident (LOCA), Anticipated Transient Without Scram (ATWS), or other accidents that do not result in severe core damage conditions.

Instrumentation to monitor the progression of core melt eygg--

~. -

l l accidents would be best addressed by the current severe accident management program.

l l

Therefore, for existing BWRs, the staff will accept the criteria of NEDO-31558. However. - for new license' applications for both conventional and advanced BWR designs there will be no change in the R.G.1.97 criteria.

l 2.0 EVALUATION l

The Code of Federal Regulations 10 CFR 50.49 requires licensees to establish a program for qualifying certain post-accident monitoring equipment for which j

specific guidance concerning the types of variables monitored is provided in R.G. 1.97, Revision 2.

This regulatory guide identifies neutron flux as a Type B variable that provides information to indicate whether plant safety functions are being accomplished. The guide identifies Category I criteria for this instrumentation. The Category I criteria includes environmental qualification, seismic qualification, Class IE power sources, and redundant i

channels.

L Qualification criteria for instrumentation is established based on the safety function of the system whose variables are being monitored.- The selection criteria for R.G.1.97 variable qualification category is based upon whether-monftoring of system parameters is needed during and following.an accident and whether subsequent operator actions are dependent on the infors1ation provided by this instrumentation.

i i

The NEDO-31558 report analyzes event scenarios to determine the consequences of neutron flux monitoring unavailability and concludes 'that the failure of this instrumentation will not prevent the operator from determining reactor power levels. Alternate parameter status will be available from which reactor power may be inferred. Some alternate indications may require more than one input to determine reactor power. However, based on the multiple inputs available to the operator, sufficient information will be available upon which to base operational decisions and to conclude that reactivity control has been accomplished. Further, NED0-31558 contains criteria regarding the range, power supplies, and qualifications for neutron flux monitoring instrumentation that provide sufficient confidence that the neutron flux monitoring i

instrumentation will be available to confirm reactor shutdown for a wide range of events including ATWS. The BWR Owners' Group also stated that for BWR design basis events, recriticality is not a significant contributor to core melt risk for BWR accident scenarios that go beyond the design basis.

Based on the BWR Owners' Group submittals, the Director of NRi, has determined that Category I neutron flux monitoring instrumentation is not needed for existing BWRs to cope with LOCA, ATWS, or other accidents that do not result in severe core damage conditions.

Instrumentation to monitor the progression of core melt accidents are best addressed by the current severe accident management program. Therefore, for existing BWRs, neutron flux monitoring instrumentation does not need to meet the Category I criteria of R.G.1.97.

Neutron flux monitoring instrumentation, at existing BWRs, need to meet the new criteria proposed by the BWR Owners' Group in NED0-31558. However, new i

i i

e 5-applications for conventional and advanced BWR designs, will be required to meet the R.G. 1.97 criteria.

Licensees should review their neutron flux monitoring instrumentation against the criteria of NEDO-31558 and confirm that they meet this criteria.

If the instrumentation does not meet the criteria, licensees should make a commitment to meet the criteria and state when this commitment will be fulfilled.

If a commitment to the criteria cannot be made, licensees should explicitly state any deviations from the criteria and provide supporting justification or alternatives.

i i

The criteria in NEDO-31558 includes the use of uniterruptable and reliable power sources. The 8WR Owners' Group and the staff agree that each redundant i

neutron flux monitoring channel should be powered from a different uninterruptable power supply (UPS). Therefore, a loss of a single UPS would not cause the loss of both channels of neutron flux monitoring instrumentation.

As stated in Section 5.2.8 of NED0-31558, each licensee should perform a plant specific evaluation to review power distribution to the neutron flux monitoring instrumentation, including recorders. The intent of this review is to verify that neutron flux monitoring instrumentation power would not be lost during events by load shedding logics or similar schemes or that a single power supply failure would not cause the loss of redundant channels of neutron flux monitoring instrumentation.

o y-ep ey-

- w

,,y

+

w-*

p-w e

y.m..

,-e,

i

~

t i

r The licenses for Grand Gulf Nuclear Station Unit I and River Bend Station contain license conditions that require the installation of Category I neutron i

flux monitoring instrumentation. Since neutron flux is no longer considered to be a Category I varishle, the staff will entertain licensee requests for

~

removal of these license conditions.

1 The licensees for Nine Mile Point Unit 2, Perry Nuclear Power Plant Unit 1, j

and WNP-2 have designated neutron flux as a Type A variable because this information is required to permit the operator to take specific manually i

controlled actions. These licensees will not be required to upgrade the qualification of the neutron flux monitoring instrumentation to meet the Category I criteria. These licensees should review their Emergency Operating Procedures (EOPs) to assure that there is no plant specific role for neutron flux monitoring that differs from the evaluation in NEDO-31558.

If the role of neutron flux monitoring does not differ from the evaluation in the NEDO report, the staff will entertain licensee requests for removal of neutron flux l

from their Type A instrument lists.

Neutron flux monitoring will no longer appear in the post-accident monitoring section of the new BWR Standard Technical Specifications, since it is no longer Category 1 instrumentation. Licensees wishing to maintain a post-accident monitoring technical specification on neutron flux monitoring instrumentation will be allowed to do so. Licensees may request the removal of neutron flux monitoring instrumentation from their post-accident monitoring technical specifications if they so desire.

i

~

l Big Rock Point was granted an exemption from the provisions of R.G. 1.97 and Limerick Generating Station Units 1 and 2 were granted deviations from the Category I criteria-for neutron flux monitoring instrumentation. Therefore, these plants do not need to meet the criteria of NED0-31558. The neutron flux monitoring instrumentation installed at Susquehanna Steam Electric Station 1

Units 1 and 2 and WNP-2 exceed the criteria of NED0-31558, and therefore, these plants may take advantage of any relaxation that the new criteria might i

provide.

3.0 CONCLUSION

I i

l Based on our review, we conclude that the post-accident neutron flux monitoring instrumentation at existing BWRs should meet the criteria in NEDD-31558.

Licensees should provide a commitment to these criteria and perform a plant specific power distribution review for neutron flux monitoring instrumentation. However, new applications for conventional and advanced BWR designs, will be required to meet the R.G.1.97 criteria.

Princioal Contributor:

B. Marcus

~

~.

References:

1.

Letter from D. G. Eisenhut (NRC) to All Licensees Of Operating Reactors, Applicants for Operating Licenses, and Holders of Construction Permits,

" Supplement No. I to NUREG-0737--Requirements for Emergency Response Capability, (Generic Letter No. 82-33)", dated December 17, 1982.

2.

Regulatory Guide 1.97, Revision 2, " Instrumentation for Light-Water-Cooled Nuclear Power Plants to Assess Plant and Environs Conditions During and Following an Accident", NRC Office of Standards Development, dated December 1980.

3.

Letter from R. F. Janecek (BWROG) to T.' E. Murley (NRC) "BWR Owners' Group Licensing Topical Report Position on NRC Regulatory Guide 1.97, Revision 3 Requirements for Post-Accident Neutron Monitoring System" (General Electric Report NEDO-31558), dated April 1,1988.

4.

Regulatory Guide 1.97, Revision 3, " Instrumentation for Light-Water-Cooled nuclear Power Plants to Assess Plant and Environs Conditions During and Following an Accident", NRC Office of Nuclear Regulatory Research, dated May 1983.

l S.

Letter from F. J. Miraglia (NRC) to S. D. Floyd (BWROG), "BWR Owners' Group Licensing Topical Report Position on NRC Regulatory Guide 1.97, Revision 3 Requirements for Post-Accident Neutron Monitoring System" (General Electric Report NEDO-31558), dated January 29, 1990.

6.

Letter from G. J. Beck (BWROG) to T. E. Murley (NRC), " Appeal of NRC Staff Decision Regarding Upgraded Neutron Flux Monitoring Systems for BWRs", dated August 16, 1990.

7.

Letter from T. E. Murley (NRC) to C. L. Tully (BWROG), " Appeal of NRC Staff Decision Regarding Upgraded Neutron Flux Monitoring Systems for BWRs", dated October 14, 1992.

    • s e