Amends 62 & 41 to Licenses NPF-81 & NPF-68,respectively, Revising TS 5.3.1 in Accordance W/Generic Ltr 90-92 Re Use of Zirconium Alloy or Stainless Steel Filler Rods within Fuel Assemblies & Use of Lead Test Assemblies
ML20035C684
Person / Time
Site: Vogtle  
Issue date: 04/01/1993
From: Matthews D
Office of Nuclear Reactor Regulation
To:
Georgia Power Co, Oglethorpe Power Corp, Municipal Electric Authority of Georgia, City of Dalton, GA
Shared Package
ML20035C687 List:
References
GL-90-092, NPF-68-A-062, NPF-81-A-041 NUDOCS 9304080316
Download: ML20035C684 (6)


Text

g* "%

f

,5 UNITED STATES f,,

j NUCLEAR REGULATORY COMMISSION

'h I f

WASHINGTON. D.C. 20555-0001 f

?g 4.....*~

GEORGIA POWER COMPANY OGLETHORPE POWER CORPORATION MUNICIPAL ELECTRIC AUTHORITY OF GEORGIA CITY OF DALTON. GEORGIA DOCKET NO. 50-424 V0GTLE ELECTRIC GENERATING PLANT. UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.62 License No. NPF-68 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment to the Vogtle Electric Generating Plant, Unit 1 (the facility), Facility Operating License No.

NPF-68 filed by the Georgia Power Company, acting for itself, Oglethorpe Power Corporation, Municipal Electric Authority of Georgia, and City of Dalton, Georgia (the licensees), dated November 5, 1992, as supplemented March 29, 1993, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of.the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations set forth in 10 CFR Chapter I; D.

The issuance of this license amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

9304080316 930401 PDR ADOCK 05000424 P

PDR

- 2.

Accordingly, the license is hereby amended by page changes to the Technical as indicated in the attachment to this license amendment and paragraph 2.C.(2) of Facility Operating License No. NPF-68 is hereby amended to read as follows:

Technical Specifications and Environmental Protection Plan The Technical Specifications contained in Appendix A, as revised through Amendment No. 62, and the Environmental Protection Plan contained in Appendix B, both of which are attached hereto, are hereby incorporated into this license.

GPC shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of its date of issuance and shall be implemented within 30 days of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION 29 David B. Matthews, Director Project Directorate 11-3 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Attachment:

Technical Specification Changes Date of Issuance:

April 1, 1993

g at %

f.

,k UNITED STATES

[ ki / j NUCLEAR REGULATORY COMMISSION

^ ( ;g g g j

WASHINGTON, D C. 20555-0001 gp GEORGIA POWER COMPANY OGLETHORPE POWER CORPORATION MUNICIPAL ELECTRIC AUTHORITY OF GEORGIA

[JTY OF DALTON. GEORGIA DOCKET NO. 50-425 V0GTLE ELECTRIC GENERATING PLANT. UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 41 License No. NPF-81 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment to the Vogtle Electric Generating Plant, Unit 2 (the facility), Facility Operating License No.

NPF-81 filed by the Georgia Power Company, acting for itself, Oglethorpe Power Corporation, Municipal Electric Authority of Georgia, and City of Dalton, Georgia (the licensees), dated November 5, 1992, as supplemented March 29, 1993, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations set forth in 10 CFR Chapter I; D.

The issuance of this license amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

_ 1 2.

Accordingly, the license is hereby amended by page changes to the

l Technical Specifications as indicated in the attachment to this license 1

amendment and paragraph 2.C.(2) of Facility Operating License No. NPF-81 l

is hereby amei.Jed to read as follows:

Technical Specifications and $' vironmental Protection Plan The Technical Specifications contained in Appendix A, a's revised through Amendment No. 41, and the Environmental Protection Plan contained in Appendix B, both of which are attached hereto, are hereby incorporated into this license.

GPC shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of its date of issuance and shall be implemented within 30 days of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION A

David B. Matthews, Director Project Directorate II-3 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Attachment:

Technical Specification Changes Date of Issuance:

April 1, 1993 1

t ATTACHMENT TO LICENSE AMENDMENT N0.62__

FACILITY OPERATING LICENSE N0. NPF-68 AND LICENSE AMENDMENT NO. 41 FACILITY OPERATING LICENSE NO. NPF-81 DOCKETS NOS. 50-424 AND 50-425 Replace the following page of the Appendix "A" Technical Specifications with the enclosed page.

The revised page is identified by Amendment number and contains a vertical line indicating the area of change.

Remove Paae Insert Pace 5-4 5-4 i

i

DESIGN FEATURES l

5.3 REACTOR CORE FUEL ASSEMBLIES i

5.3.1 The core shall contain 193 fuel assemblies with each fuel assembly containing 264 fuel rods clad with Zircaloy-4 except for two fuel assemblies which may each contain up to twelve (12) fuel rods clad with ZIRLO*.

Each fuel rod shall have a nominal active fuel length of 144 inches.

The initial core loading shall have a maximum enrichment not to exceed 3.2 weight percent U-235. Reload fuel shall be similar in physical design to the initial core loading and shall have a maximum enrichment not to exceed 4.55 weight percent U-235.

Limited substitutions of zirconium alloy or stainless steel filler rods for fuel rods, in accordance with NRC-approved applications of fuel rod configurations, may be used.

Fuel assemblies shall be limited to those fuel designs that have been analyzed with applicable NRC staff-approved codes and methods, and shown by tests or analyses to comply with all fuel safety design bases. A limited number of lead test assemblies that have not completed representative testing may be placed in non-limiting core regions.

CONTROL R00 ASSEMBLIES 5.3.2 The core shall contain 53 full-length control rod assemblies. The control rod assemblies shall contain a nominal 142 inches of absorber material.

The nominal absorber composition shall be 95.5% natural halfnium and 4.5%

natural zirconium and/or 80% silver,15% indium, and 5% cadmium. All control rods shall be clad with stainless steel.

5.4 REACTOR COOLANT SYSTEM DESIGN PRESSURE AND TEMPERATURE 5.4.1 The Reactor Coolant System is designed and shall be maintained:

a.

In accordance with the Code requirements specified in Section 5.2 of the FSAR, with allowance for normal degradation pursuant to the applicable Surveillance Requirements, b.

For a pressure of 2485 psig, and c.

For a temperature of 650*F, except for the pressurizer which is 680*F.

VOLUME 5.4.2 The total water and steam volume of the Reactor Coolant System is 12,240 100 cubic feet at a nominal T,y of 588.5'F.

5.5 METEOROLOGICAL TOWER LOCATION 5.5.1 The meteorological tower shall be located as shown on Figure 5.1-1 and 5.1-2.

V0GTLE UNITS - 1 & 2 5-4 Amendment No. 62 (Unit 1)

Amendment No. 41 (Unit 2)

-