Requests in-depth Analysis of Issues Re Metal Flanges Made in Peoples Republic of China That May Pose Threat to Human Health or Property
ML20035C515
Person / Time
Site: Seabrook 
Issue date: 02/16/1993
From: Lieberman J
SENATE, ENVIRONMENT & PUBLIC WORKS
To: Taylor J
NRC OFFICE OF THE EXECUTIVE DIRECTOR FOR OPERATIONS (EDO)
Shared Package
ML20035A972 List:
References
NUDOCS 9304080056
Download: ML20035C515 (2)


Text

r JOSEPH f. LtEBERMAN se=4n ors sonomo wasgstg oc 2 510 4

  • . coNNEctcut.

.i CDMMfTTE 4 5 (Q

{}

s (NVmON AN B C WORKS HA*T'omo CT 06103 -

GOVERNMENTAL AFFAIRS SMALL BUSINESS WASHINGTON, DC 20510-0703 fo[2 g 6 February 16, 1993

[

k Mr. James Taylor dxecutive Director i

Nuclear Regulatory Commission Washington, DC 20555 i

3

Dear Mr. Taylor:

i' It has been brought to my attention by concerned constituents, as well as by the National Board of Boiler and Pressure Vessel Inspectors (NBBPVI) of Columbus, Ohio, that metal flanges made in the Peoples Republic of China have been-distributed'in the United States, Canada and South America.

According to a television news story aired December 9, 1992 on i

WFSB in Hartford, Connecticut, these flanges may be considered a threat to both lives and property.

The WFSB story specifically i

' referred to the flanges used at the Seabrook, New Hampshire nuclear power plant.

l 1

According to-the NBBPVI September 1992 publication "Special Report:

The Chinese Flange Investigation," certain metal flanges l

do not conform to ANSI B16.5 and ASTM A105 standards.

(This' analysis is enclosed.)

This analysis is apparently based on inspections done for NBBPVI by Columbus Metallurgical Services, Inc. and by Welding Consultants, Inc., which used non-destructive l

methods including magnetic particle, dye ~ penetrant and ultrasonic testing.

Conclusions reached by the consulting firms for-the Special Report indicate that the flanges were either:

(1) not forged to ANSI / ASTM standards as specified, or (2) were misfabricated and " slugged"-(the addition of non-homogeneous filler) to correct for under dimensioning or local defects.

l Although NBBPVI concludes in its Special Report that no in-service failures related to these flanges has yet occurred, I am concerned by its comments that failures reported during l

hydrostatic tests or during process inspections may lead to more t

serious incidents wherever pressure piping, boilers and pressure vessels (including nuclear facilities) are employed.

In December, my staff requested that the NRC do a complete review of where these flanges are located and whether they pose risks to human health or property.

An interim oral report was provided.

EDO ~ ggggg8

_7

03. C 1gg I

930(080056 930318ADOCK 05000443

'*NTto ou nic,cito,,,,,

PDR PDR U

; ~> ;.

I am requesting your in-depth analysis of~this issue with respect to all facilities under your jurisdiction.

Addi_tionally, I am requesting that you coordinate this review with other federal and state agencies.

Please report to me on other facilities that may be utilizing or storing these flanges and what steps are being taken to address any safety' issues...

er y, /

J p

ieberman Cliai S#ab6cmmittee.on Clean Air jndNuclearRegulation JIL/meh Enclosure

(

f I

6 e

Page 2 t

i